Comparison of high resolution T2W and Gd-T1W of MRI internal acoustic canal in sensorineural hearing loss

© 2016, Medical Association of Thailand. All rights reserved. Objective: To evaluate the concordance of high resolution T2-weighted (HR-T2W) and Gd-T1W for mass detection in internal acoustic canal (IAC) or cochlear in sensorineural hearing loss (SNHL). Material and Method: The retrospective study o...

Full description

Saved in:
Bibliographic Details
Main Authors: Panida Charnchaowanish, Orasa Chawalparit
Other Authors: Mahidol University
Format: Article
Published: 2018
Subjects:
Online Access:https://repository.li.mahidol.ac.th/handle/123456789/41032
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Mahidol University
id th-mahidol.41032
record_format dspace
spelling th-mahidol.410322019-03-14T15:01:58Z Comparison of high resolution T2W and Gd-T1W of MRI internal acoustic canal in sensorineural hearing loss Panida Charnchaowanish Orasa Chawalparit Mahidol University Medicine © 2016, Medical Association of Thailand. All rights reserved. Objective: To evaluate the concordance of high resolution T2-weighted (HR-T2W) and Gd-T1W for mass detection in internal acoustic canal (IAC) or cochlear in sensorineural hearing loss (SNHL). Material and Method: The retrospective study of patients with SNHL undergoing magnetic resonance imaging (MRI) IAC protocol was performed. HR-T2W and Gd-T1W were separately reviewed for any mass in IAC or cochlear. Results: One hundred eight cases were available for evaluation with 43 males and 65 females (mean age of 56.04 years old; range 15 to 86 years old). Symptoms of SNHL on right side were 39 cases (36.1%), left side 39 cases (36.1%), both sides 15 cases (13.9%), and asymmetric SNHL 15 cases (13.9%). Twenty two (20.4%) cases had mass in IAC and/or cochlear demonstrated on both HR-T2W and Gd-T1W. No discrepancy of abnormality detection between both pulse sequences was found. Conclusion: HR-T2W was as accurate as Gd-T1W in detecting mass in IAC and cochlear in patients with SNHL. Screening with HR-T2W could be used with confidence and might be reasonable to reducing cost of the MRI study in appropriate setting of patients presenting with SNHL. 2018-12-11T03:18:24Z 2019-03-14T08:01:58Z 2018-12-11T03:18:24Z 2019-03-14T08:01:58Z 2016-11-01 Article Journal of the Medical Association of Thailand. Vol.99, No.11 (2016), 1245-1249 01252208 2-s2.0-85010869425 https://repository.li.mahidol.ac.th/handle/123456789/41032 Mahidol University SCOPUS https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85010869425&origin=inward
institution Mahidol University
building Mahidol University Library
continent Asia
country Thailand
Thailand
content_provider Mahidol University Library
collection Mahidol University Institutional Repository
topic Medicine
spellingShingle Medicine
Panida Charnchaowanish
Orasa Chawalparit
Comparison of high resolution T2W and Gd-T1W of MRI internal acoustic canal in sensorineural hearing loss
description © 2016, Medical Association of Thailand. All rights reserved. Objective: To evaluate the concordance of high resolution T2-weighted (HR-T2W) and Gd-T1W for mass detection in internal acoustic canal (IAC) or cochlear in sensorineural hearing loss (SNHL). Material and Method: The retrospective study of patients with SNHL undergoing magnetic resonance imaging (MRI) IAC protocol was performed. HR-T2W and Gd-T1W were separately reviewed for any mass in IAC or cochlear. Results: One hundred eight cases were available for evaluation with 43 males and 65 females (mean age of 56.04 years old; range 15 to 86 years old). Symptoms of SNHL on right side were 39 cases (36.1%), left side 39 cases (36.1%), both sides 15 cases (13.9%), and asymmetric SNHL 15 cases (13.9%). Twenty two (20.4%) cases had mass in IAC and/or cochlear demonstrated on both HR-T2W and Gd-T1W. No discrepancy of abnormality detection between both pulse sequences was found. Conclusion: HR-T2W was as accurate as Gd-T1W in detecting mass in IAC and cochlear in patients with SNHL. Screening with HR-T2W could be used with confidence and might be reasonable to reducing cost of the MRI study in appropriate setting of patients presenting with SNHL.
author2 Mahidol University
author_facet Mahidol University
Panida Charnchaowanish
Orasa Chawalparit
format Article
author Panida Charnchaowanish
Orasa Chawalparit
author_sort Panida Charnchaowanish
title Comparison of high resolution T2W and Gd-T1W of MRI internal acoustic canal in sensorineural hearing loss
title_short Comparison of high resolution T2W and Gd-T1W of MRI internal acoustic canal in sensorineural hearing loss
title_full Comparison of high resolution T2W and Gd-T1W of MRI internal acoustic canal in sensorineural hearing loss
title_fullStr Comparison of high resolution T2W and Gd-T1W of MRI internal acoustic canal in sensorineural hearing loss
title_full_unstemmed Comparison of high resolution T2W and Gd-T1W of MRI internal acoustic canal in sensorineural hearing loss
title_sort comparison of high resolution t2w and gd-t1w of mri internal acoustic canal in sensorineural hearing loss
publishDate 2018
url https://repository.li.mahidol.ac.th/handle/123456789/41032
_version_ 1763488535295295488