Energy Consumption Collection Design for Smart Building

© 2018 IEEE. With increasing cost and energy consumption, many organizations would find a way for monitoring and to save energy. Our work would design and implement a monitoring system to collect energy usage data and use such data to analyze energy consumption patterns. We measure the amount of ele...

Full description

Saved in:
Bibliographic Details
Main Authors: T. Tantidham, S. Ngamsuriyaros, N. Tungamnuayrith, T. Nildam, K. Banthao, P. Intakot
Other Authors: Mahidol University
Format: Conference or Workshop Item
Published: 2019
Subjects:
Online Access:https://repository.li.mahidol.ac.th/handle/123456789/45599
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Mahidol University
id th-mahidol.45599
record_format dspace
spelling th-mahidol.455992019-08-23T18:29:54Z Energy Consumption Collection Design for Smart Building T. Tantidham S. Ngamsuriyaros N. Tungamnuayrith T. Nildam K. Banthao P. Intakot Mahidol University Computer Science Mathematics © 2018 IEEE. With increasing cost and energy consumption, many organizations would find a way for monitoring and to save energy. Our work would design and implement a monitoring system to collect energy usage data and use such data to analyze energy consumption patterns. We measure the amount of electricity of AC outlets, lights and air conditions in a building. Our work consists of 3 parts: Power Data Collection, Data Processing and Data Report. Power Data Collection is composed of power meters built on an ESP8266 Wi-Fi platform and PZEM-004T which will be attached to 3 types of devices: AC outlet, air condition and light. The Data Processing part is performed at the Elasticsearch server by gathering the measured power data from multiple power meters via MQTT protocol. The Data Report part uses Grafana to show usage statistics via a web interface. Usually, one room will have number of lights and outlets, and one or two air conditions. We also collect the measured data every 15 minutes. Thus, collected data will become very huge in a short period of time. In the future, we need to do pattern analysis of energy consumption of a building. 2019-08-23T10:55:42Z 2019-08-23T10:55:42Z 2018-08-20 Conference Paper 2018 International Conference on Embedded Systems and Intelligent Technology and International Conference on Information and Communication Technology for Embedded Systems, ICESIT-ICICTES 2018. (2018) 10.1109/ICESIT-ICICTES.2018.8442052 2-s2.0-85053430091 https://repository.li.mahidol.ac.th/handle/123456789/45599 Mahidol University SCOPUS https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85053430091&origin=inward
institution Mahidol University
building Mahidol University Library
continent Asia
country Thailand
Thailand
content_provider Mahidol University Library
collection Mahidol University Institutional Repository
topic Computer Science
Mathematics
spellingShingle Computer Science
Mathematics
T. Tantidham
S. Ngamsuriyaros
N. Tungamnuayrith
T. Nildam
K. Banthao
P. Intakot
Energy Consumption Collection Design for Smart Building
description © 2018 IEEE. With increasing cost and energy consumption, many organizations would find a way for monitoring and to save energy. Our work would design and implement a monitoring system to collect energy usage data and use such data to analyze energy consumption patterns. We measure the amount of electricity of AC outlets, lights and air conditions in a building. Our work consists of 3 parts: Power Data Collection, Data Processing and Data Report. Power Data Collection is composed of power meters built on an ESP8266 Wi-Fi platform and PZEM-004T which will be attached to 3 types of devices: AC outlet, air condition and light. The Data Processing part is performed at the Elasticsearch server by gathering the measured power data from multiple power meters via MQTT protocol. The Data Report part uses Grafana to show usage statistics via a web interface. Usually, one room will have number of lights and outlets, and one or two air conditions. We also collect the measured data every 15 minutes. Thus, collected data will become very huge in a short period of time. In the future, we need to do pattern analysis of energy consumption of a building.
author2 Mahidol University
author_facet Mahidol University
T. Tantidham
S. Ngamsuriyaros
N. Tungamnuayrith
T. Nildam
K. Banthao
P. Intakot
format Conference or Workshop Item
author T. Tantidham
S. Ngamsuriyaros
N. Tungamnuayrith
T. Nildam
K. Banthao
P. Intakot
author_sort T. Tantidham
title Energy Consumption Collection Design for Smart Building
title_short Energy Consumption Collection Design for Smart Building
title_full Energy Consumption Collection Design for Smart Building
title_fullStr Energy Consumption Collection Design for Smart Building
title_full_unstemmed Energy Consumption Collection Design for Smart Building
title_sort energy consumption collection design for smart building
publishDate 2019
url https://repository.li.mahidol.ac.th/handle/123456789/45599
_version_ 1763488403534381056