Childhood Glaucoma: Long-Term Outcomes of Glaucoma Drainage Device Implantation Within the First 2 Years of Life

© 2019 Wolters Kluwer Health, Inc. Précis:Glaucoma drainage device (GDD) implantation within the first 2 years of life yields an overall success rate of 59.0% at 5 years. It is safe and requires a relatively low number of postoperative interventions.Purpose:The purpose of this study was to evaluate...

Full description

Saved in:
Bibliographic Details
Main Authors: Moritz C. Daniel, Jibran Mohamed-Noriega, Sakaorat Petchyim, John Brookes
Other Authors: Universität Freiburg im Breisgau
Format: Article
Published: 2020
Subjects:
Online Access:https://repository.li.mahidol.ac.th/handle/123456789/51398
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Mahidol University
id th-mahidol.51398
record_format dspace
spelling th-mahidol.513982020-01-27T16:29:05Z Childhood Glaucoma: Long-Term Outcomes of Glaucoma Drainage Device Implantation Within the First 2 Years of Life Moritz C. Daniel Jibran Mohamed-Noriega Sakaorat Petchyim John Brookes Universität Freiburg im Breisgau UCL Hospital Universitario Dr. Jose Eleuterio Gonzalez Moorfields Eye Hospital NHS Foundation Trust Faculty of Medicine, Siriraj Hospital, Mahidol University Medicine © 2019 Wolters Kluwer Health, Inc. Précis:Glaucoma drainage device (GDD) implantation within the first 2 years of life yields an overall success rate of 59.0% at 5 years. It is safe and requires a relatively low number of postoperative interventions.Purpose:The purpose of this study was to evaluate the long-term outcomes of the treatment of childhood glaucoma with GDDs within the first 2 years of life.Methods:A total of 43 children (60 eyes) having undergone GDD implantation within the first 2 years of life at Moorfields Eye Hospital between July 2005 and November 2014 were included in this retrospective case series. Kaplan-Meier survival curves were created for the evaluation of surgical success. Log-rank analysis was performed for the detection of risk factors for failure. Main outcome measures: Overall success rates at 1, 5, and 7 years after surgery. Surgical success: intraocular pressure ≥5/≤21 mm Hg, no further glaucoma surgery required, nonoccurrence of loss of perception of light or devastating complications.Results:The results are listed as follows: Median duration of follow-up was 48.0 months. Median age at surgery was 11.5 months. Seventy-three percentage of children were white. Most common types of glaucoma were primary congenital glaucoma [(PCG); 67%], glaucoma following cataract surgery (18%), and anterior segment dysgenesis (10%). Overall success rates were 93%, 59%, and 59%, respectively. There were no differences in the survival rates as a function of PCG/non-PCG, sex, and removal of intraluminal stent suture. Mean number of general anesthesia administrations during the first postoperative year was 1.8.Conclusions:GDD implantation within the first 2 years of life is effective and safe. The low number of general anesthesia administrations required during the first postoperative year could help to reduce the burden placed on children and carers. Further research is required to directly compare the efficiency of GDD implantation with other surgical options. 2020-01-27T09:29:05Z 2020-01-27T09:29:05Z 2019-10-01 Article Journal of Glaucoma. Vol.28, No.10 (2019), 878-883 10.1097/IJG.0000000000001336 1536481X 10570829 2-s2.0-85071254001 https://repository.li.mahidol.ac.th/handle/123456789/51398 Mahidol University SCOPUS https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85071254001&origin=inward
institution Mahidol University
building Mahidol University Library
continent Asia
country Thailand
Thailand
content_provider Mahidol University Library
collection Mahidol University Institutional Repository
topic Medicine
spellingShingle Medicine
Moritz C. Daniel
Jibran Mohamed-Noriega
Sakaorat Petchyim
John Brookes
Childhood Glaucoma: Long-Term Outcomes of Glaucoma Drainage Device Implantation Within the First 2 Years of Life
description © 2019 Wolters Kluwer Health, Inc. Précis:Glaucoma drainage device (GDD) implantation within the first 2 years of life yields an overall success rate of 59.0% at 5 years. It is safe and requires a relatively low number of postoperative interventions.Purpose:The purpose of this study was to evaluate the long-term outcomes of the treatment of childhood glaucoma with GDDs within the first 2 years of life.Methods:A total of 43 children (60 eyes) having undergone GDD implantation within the first 2 years of life at Moorfields Eye Hospital between July 2005 and November 2014 were included in this retrospective case series. Kaplan-Meier survival curves were created for the evaluation of surgical success. Log-rank analysis was performed for the detection of risk factors for failure. Main outcome measures: Overall success rates at 1, 5, and 7 years after surgery. Surgical success: intraocular pressure ≥5/≤21 mm Hg, no further glaucoma surgery required, nonoccurrence of loss of perception of light or devastating complications.Results:The results are listed as follows: Median duration of follow-up was 48.0 months. Median age at surgery was 11.5 months. Seventy-three percentage of children were white. Most common types of glaucoma were primary congenital glaucoma [(PCG); 67%], glaucoma following cataract surgery (18%), and anterior segment dysgenesis (10%). Overall success rates were 93%, 59%, and 59%, respectively. There were no differences in the survival rates as a function of PCG/non-PCG, sex, and removal of intraluminal stent suture. Mean number of general anesthesia administrations during the first postoperative year was 1.8.Conclusions:GDD implantation within the first 2 years of life is effective and safe. The low number of general anesthesia administrations required during the first postoperative year could help to reduce the burden placed on children and carers. Further research is required to directly compare the efficiency of GDD implantation with other surgical options.
author2 Universität Freiburg im Breisgau
author_facet Universität Freiburg im Breisgau
Moritz C. Daniel
Jibran Mohamed-Noriega
Sakaorat Petchyim
John Brookes
format Article
author Moritz C. Daniel
Jibran Mohamed-Noriega
Sakaorat Petchyim
John Brookes
author_sort Moritz C. Daniel
title Childhood Glaucoma: Long-Term Outcomes of Glaucoma Drainage Device Implantation Within the First 2 Years of Life
title_short Childhood Glaucoma: Long-Term Outcomes of Glaucoma Drainage Device Implantation Within the First 2 Years of Life
title_full Childhood Glaucoma: Long-Term Outcomes of Glaucoma Drainage Device Implantation Within the First 2 Years of Life
title_fullStr Childhood Glaucoma: Long-Term Outcomes of Glaucoma Drainage Device Implantation Within the First 2 Years of Life
title_full_unstemmed Childhood Glaucoma: Long-Term Outcomes of Glaucoma Drainage Device Implantation Within the First 2 Years of Life
title_sort childhood glaucoma: long-term outcomes of glaucoma drainage device implantation within the first 2 years of life
publishDate 2020
url https://repository.li.mahidol.ac.th/handle/123456789/51398
_version_ 1763494376318697472