Pediatric elbow measurement parameters: Evaluation of the six angles in inter- and intra-observer reliability
© 2018 Background: Several radiographic measurements of the humerus can be used to evaluate the treatment outcome of supracondylar fractures in children. Because of the cartilaginous nature of the immature elbow, interpretation of radiographs around this area is sometimes challenging and can be unre...
Saved in:
Main Authors: | , , , , , |
---|---|
Other Authors: | |
Format: | Article |
Published: |
2020
|
Subjects: | |
Online Access: | https://repository.li.mahidol.ac.th/handle/123456789/51554 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Mahidol University |
id |
th-mahidol.51554 |
---|---|
record_format |
dspace |
spelling |
th-mahidol.515542020-01-27T16:41:51Z Pediatric elbow measurement parameters: Evaluation of the six angles in inter- and intra-observer reliability Purinon Suangyanon Ornusa Chalayon Kitti Worawuthangkul Kamolporn Kaewpornsawan Thanase Ariyawatkul Perajit Eamsobhana Faculty of Medicine, Siriraj Hospital, Mahidol University Medicine © 2018 Background: Several radiographic measurements of the humerus can be used to evaluate the treatment outcome of supracondylar fractures in children. Because of the cartilaginous nature of the immature elbow, interpretation of radiographs around this area is sometimes challenging and can be unreliable. This study was conducted to determine the inter-observer and intra-observer reliability of the six commonly used radiographic measurements of the distal humerus. Method: The Baumann angle, humero-ulna angle, metaphyseal-diaphyseal angle, radial epiphyseal angle, shaft-condylar angle and lateral capitellohumeral angle of the humerus were measured by two observers on the radiographs of uninjured elbows from 58 children. The values between each measurement were compared and correlated using a Pearson coefficient of correlation to determine the inter-observer and intra-observer reliability. Results: All of the radiographic parameters showed excellent intra-observer reliability with the correlation coefficient values of the Baumann angle, humero-ulna angle, metaphyseal-diaphyseal angle, radial epiphyseal angle, shaft-condylar angle, lateral capitellohumeral angle as 0.945, 0.95, 0.909, 0.888, 0.961 and 0.975 (p < 0.001), respectively. The inter-observer reliability of the Baumann and humero-ulna angles were also found to be highly correlated at r = 0.843 (p < 0.001) and 0.878 (p < 0.001), respectively. The metaphyseal-diaphyseal angle had poor reliability with r = 0.136 (p = 0.291) while the radial epiphyseal angle, shaft-condylar angle, and lateral capitellohumeral angle demonstrated good reliability with r = 0.675 (p < 0.001), 0.747 (p < 0.001), and 0.686 (p < 0.001), respectively. Conclusion: The Baumann angle and humero-ulna angle measurements of distal humerus showed excellent inter- and intra-observer reliability. Both parameters represent repeatable and reliable methods for determining the outcome of supracondylar humeral fractures in pediatric population. 2020-01-27T09:41:51Z 2020-01-27T09:41:51Z 2019-07-01 Article Journal of Clinical Orthopaedics and Trauma. Vol.10, No.4 (2019), 792-796 10.1016/j.jcot.2018.07.019 22133445 09765662 2-s2.0-85050689907 https://repository.li.mahidol.ac.th/handle/123456789/51554 Mahidol University SCOPUS https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85050689907&origin=inward |
institution |
Mahidol University |
building |
Mahidol University Library |
continent |
Asia |
country |
Thailand Thailand |
content_provider |
Mahidol University Library |
collection |
Mahidol University Institutional Repository |
topic |
Medicine |
spellingShingle |
Medicine Purinon Suangyanon Ornusa Chalayon Kitti Worawuthangkul Kamolporn Kaewpornsawan Thanase Ariyawatkul Perajit Eamsobhana Pediatric elbow measurement parameters: Evaluation of the six angles in inter- and intra-observer reliability |
description |
© 2018 Background: Several radiographic measurements of the humerus can be used to evaluate the treatment outcome of supracondylar fractures in children. Because of the cartilaginous nature of the immature elbow, interpretation of radiographs around this area is sometimes challenging and can be unreliable. This study was conducted to determine the inter-observer and intra-observer reliability of the six commonly used radiographic measurements of the distal humerus. Method: The Baumann angle, humero-ulna angle, metaphyseal-diaphyseal angle, radial epiphyseal angle, shaft-condylar angle and lateral capitellohumeral angle of the humerus were measured by two observers on the radiographs of uninjured elbows from 58 children. The values between each measurement were compared and correlated using a Pearson coefficient of correlation to determine the inter-observer and intra-observer reliability. Results: All of the radiographic parameters showed excellent intra-observer reliability with the correlation coefficient values of the Baumann angle, humero-ulna angle, metaphyseal-diaphyseal angle, radial epiphyseal angle, shaft-condylar angle, lateral capitellohumeral angle as 0.945, 0.95, 0.909, 0.888, 0.961 and 0.975 (p < 0.001), respectively. The inter-observer reliability of the Baumann and humero-ulna angles were also found to be highly correlated at r = 0.843 (p < 0.001) and 0.878 (p < 0.001), respectively. The metaphyseal-diaphyseal angle had poor reliability with r = 0.136 (p = 0.291) while the radial epiphyseal angle, shaft-condylar angle, and lateral capitellohumeral angle demonstrated good reliability with r = 0.675 (p < 0.001), 0.747 (p < 0.001), and 0.686 (p < 0.001), respectively. Conclusion: The Baumann angle and humero-ulna angle measurements of distal humerus showed excellent inter- and intra-observer reliability. Both parameters represent repeatable and reliable methods for determining the outcome of supracondylar humeral fractures in pediatric population. |
author2 |
Faculty of Medicine, Siriraj Hospital, Mahidol University |
author_facet |
Faculty of Medicine, Siriraj Hospital, Mahidol University Purinon Suangyanon Ornusa Chalayon Kitti Worawuthangkul Kamolporn Kaewpornsawan Thanase Ariyawatkul Perajit Eamsobhana |
format |
Article |
author |
Purinon Suangyanon Ornusa Chalayon Kitti Worawuthangkul Kamolporn Kaewpornsawan Thanase Ariyawatkul Perajit Eamsobhana |
author_sort |
Purinon Suangyanon |
title |
Pediatric elbow measurement parameters: Evaluation of the six angles in inter- and intra-observer reliability |
title_short |
Pediatric elbow measurement parameters: Evaluation of the six angles in inter- and intra-observer reliability |
title_full |
Pediatric elbow measurement parameters: Evaluation of the six angles in inter- and intra-observer reliability |
title_fullStr |
Pediatric elbow measurement parameters: Evaluation of the six angles in inter- and intra-observer reliability |
title_full_unstemmed |
Pediatric elbow measurement parameters: Evaluation of the six angles in inter- and intra-observer reliability |
title_sort |
pediatric elbow measurement parameters: evaluation of the six angles in inter- and intra-observer reliability |
publishDate |
2020 |
url |
https://repository.li.mahidol.ac.th/handle/123456789/51554 |
_version_ |
1763489749275770880 |