Reliability and correlation of the force-pro device and computer-assisted navigation system for measurement of acetabular cup position in total hip arthroplasty

© 2020 Surgical Technology International™. Introduction: Acetabular cup malposition is very common in total hip arthroplasty (THA) and is significantly associated with many serious postoperative complications, such as dislocation, wear and loosening, and decreased range of motion. To improve the acc...

Full description

Saved in:
Bibliographic Details
Main Authors: Chaiyanun Vijittrakarnrung, Warakorn Charoensuk, Paphon Sa-Ngasoongsong, Udomporn Manupibul, Siwadol Wongsak
Other Authors: Faculty of Medicine, Ramathibodi Hospital, Mahidol University
Format: Article
Published: 2020
Subjects:
Online Access:https://repository.li.mahidol.ac.th/handle/123456789/58157
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Mahidol University
id th-mahidol.58157
record_format dspace
spelling th-mahidol.581572020-08-25T17:42:37Z Reliability and correlation of the force-pro device and computer-assisted navigation system for measurement of acetabular cup position in total hip arthroplasty Chaiyanun Vijittrakarnrung Warakorn Charoensuk Paphon Sa-Ngasoongsong Udomporn Manupibul Siwadol Wongsak Faculty of Medicine, Ramathibodi Hospital, Mahidol University Mahidol University Medicine © 2020 Surgical Technology International™. Introduction: Acetabular cup malposition is very common in total hip arthroplasty (THA) and is significantly associated with many serious postoperative complications, such as dislocation, wear and loosening, and decreased range of motion. To improve the accuracy of intraoperative assessment, we recently developed an innovative sensor-based navigation system (Force-PRO device) using an inertial measurement unit and a 3D-printed liner for acetabular cup measurement, and aimed to evaluate its reliability and correlate its accuracy with that of a computer-assisted navigation system (CANS). Design: Method-comparison study between the Force-PRO device and a standard CANS in a 1:1 pelvic bone model. Methods: The test-retest reliability of both the Force-PRO device and CANS, and agreement between the Force-PRO device and CANS, for the measurement of acetabular inclination and anteversion angles, were examined using 40 random acetabular cup positions. Statistical analysis was performed by using limits of agreement and intraclass correlation coefficient (ICC). Results: The mean differences in the inclination angle and anteversion angle in test-retest of the Force-PRO device were-0.43°±1.03° and-0.40°±0.78°, respectively. The mean differences in the inclination angle and anteversion angle between the Force-PRO device and CANS were 0.70°±0.94° and -0.10°±0.44°, respectively. Excellent reliability in the inclination and anteversion angles of the Force-PRO device and excellent agreement between the Force-PRO device and CANS were demonstrated, with ICC values of 0.994 and 0.997, and 0.993 and 0.999, respectively Conclusion: The Force-PRO device showed excellent reliability equivalent to CANS with excellent agreement in acetabular cup position measurement comparable to that with CANS. Future clinical studies will be needed to evaluate the efficacy of this device. 2020-08-25T10:42:37Z 2020-08-25T10:42:37Z 2020-05-01 Article Surgical Technology International. Vol.36, (2020), 1-5 10903941 2-s2.0-85087816300 https://repository.li.mahidol.ac.th/handle/123456789/58157 Mahidol University SCOPUS https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85087816300&origin=inward
institution Mahidol University
building Mahidol University Library
continent Asia
country Thailand
Thailand
content_provider Mahidol University Library
collection Mahidol University Institutional Repository
topic Medicine
spellingShingle Medicine
Chaiyanun Vijittrakarnrung
Warakorn Charoensuk
Paphon Sa-Ngasoongsong
Udomporn Manupibul
Siwadol Wongsak
Reliability and correlation of the force-pro device and computer-assisted navigation system for measurement of acetabular cup position in total hip arthroplasty
description © 2020 Surgical Technology International™. Introduction: Acetabular cup malposition is very common in total hip arthroplasty (THA) and is significantly associated with many serious postoperative complications, such as dislocation, wear and loosening, and decreased range of motion. To improve the accuracy of intraoperative assessment, we recently developed an innovative sensor-based navigation system (Force-PRO device) using an inertial measurement unit and a 3D-printed liner for acetabular cup measurement, and aimed to evaluate its reliability and correlate its accuracy with that of a computer-assisted navigation system (CANS). Design: Method-comparison study between the Force-PRO device and a standard CANS in a 1:1 pelvic bone model. Methods: The test-retest reliability of both the Force-PRO device and CANS, and agreement between the Force-PRO device and CANS, for the measurement of acetabular inclination and anteversion angles, were examined using 40 random acetabular cup positions. Statistical analysis was performed by using limits of agreement and intraclass correlation coefficient (ICC). Results: The mean differences in the inclination angle and anteversion angle in test-retest of the Force-PRO device were-0.43°±1.03° and-0.40°±0.78°, respectively. The mean differences in the inclination angle and anteversion angle between the Force-PRO device and CANS were 0.70°±0.94° and -0.10°±0.44°, respectively. Excellent reliability in the inclination and anteversion angles of the Force-PRO device and excellent agreement between the Force-PRO device and CANS were demonstrated, with ICC values of 0.994 and 0.997, and 0.993 and 0.999, respectively Conclusion: The Force-PRO device showed excellent reliability equivalent to CANS with excellent agreement in acetabular cup position measurement comparable to that with CANS. Future clinical studies will be needed to evaluate the efficacy of this device.
author2 Faculty of Medicine, Ramathibodi Hospital, Mahidol University
author_facet Faculty of Medicine, Ramathibodi Hospital, Mahidol University
Chaiyanun Vijittrakarnrung
Warakorn Charoensuk
Paphon Sa-Ngasoongsong
Udomporn Manupibul
Siwadol Wongsak
format Article
author Chaiyanun Vijittrakarnrung
Warakorn Charoensuk
Paphon Sa-Ngasoongsong
Udomporn Manupibul
Siwadol Wongsak
author_sort Chaiyanun Vijittrakarnrung
title Reliability and correlation of the force-pro device and computer-assisted navigation system for measurement of acetabular cup position in total hip arthroplasty
title_short Reliability and correlation of the force-pro device and computer-assisted navigation system for measurement of acetabular cup position in total hip arthroplasty
title_full Reliability and correlation of the force-pro device and computer-assisted navigation system for measurement of acetabular cup position in total hip arthroplasty
title_fullStr Reliability and correlation of the force-pro device and computer-assisted navigation system for measurement of acetabular cup position in total hip arthroplasty
title_full_unstemmed Reliability and correlation of the force-pro device and computer-assisted navigation system for measurement of acetabular cup position in total hip arthroplasty
title_sort reliability and correlation of the force-pro device and computer-assisted navigation system for measurement of acetabular cup position in total hip arthroplasty
publishDate 2020
url https://repository.li.mahidol.ac.th/handle/123456789/58157
_version_ 1763491031476600832