Transvenous Lead Extraction (TLE) Procedure: Experience from a Tertiary Care Center in Thailand

Background: Transvenous Lead Extraction (TLE) is a standard treatment for some late Cardiac Implantable Electronics Device (CIED) complications. The outcome of transvenous lead extraction procedure in Thailand is not robust. Methods: A Single-center retrospective cohort of TLE procedures performed a...

Full description

Saved in:
Bibliographic Details
Main Authors: Natcha Soontornmanokati, Chulaporn Sirikhamkorn, Nilubon Methachittiphan, Kumpol Chintanavilas, Sanatcha Apakuppakul, Tachapong Ngarmukos, Sirin Apiyasawat, Wachara Lohawijarn, Pakorn Chandanamattha
Other Authors: Faculty of Medicine Ramathibodi Hospital, Mahidol University
Format: Article
Published: 2022
Subjects:
Online Access:https://repository.li.mahidol.ac.th/handle/123456789/74586
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Mahidol University
id th-mahidol.74586
record_format dspace
spelling th-mahidol.745862022-08-04T11:23:45Z Transvenous Lead Extraction (TLE) Procedure: Experience from a Tertiary Care Center in Thailand Natcha Soontornmanokati Chulaporn Sirikhamkorn Nilubon Methachittiphan Kumpol Chintanavilas Sanatcha Apakuppakul Tachapong Ngarmukos Sirin Apiyasawat Wachara Lohawijarn Pakorn Chandanamattha Faculty of Medicine Ramathibodi Hospital, Mahidol University Medicine Background: Transvenous Lead Extraction (TLE) is a standard treatment for some late Cardiac Implantable Electronics Device (CIED) complications. The outcome of transvenous lead extraction procedure in Thailand is not robust. Methods: A Single-center retrospective cohort of TLE procedures performed at Ramathibodi hospital between January 2008 and December 2020 was studied. Results: There were 157 leads from 105 patients who underwent lead removal procedure during the specified period. Data analysis was performed from 79 TLE patients due to incomplete data and lead explant procedure of the excluded subjects. Mean patients’ age was 57.7 ± 18.7 years, with 70.9% male. There were 82 pacemaker leads, 35 ICD leads, and 5 CS leads (mean number of leads were 1.54 ± 0.66 per patient), with mean implanted duration of 87.8 ± 68.2 months. Main indication for TLE was infection-related, which accounted for 67.1% of the cases. Overall clinical success rate was 97.5%. Mean operative time was 163.8 ± 69.5 min. Major complications occurred in 4 patients (5.1%) with one in-hospital mortality from severe sepsis. Conclusion: TLE using laser sheath and rotating mechanical sheath for transvenous lead extraction is effective and safe, even outside high-volume center. 2022-08-04T04:23:45Z 2022-08-04T04:23:45Z 2022-05-01 Article Indian Pacing and Electrophysiology Journal. Vol.22, No.3 (2022), 123-128 10.1016/j.ipej.2022.02.021 09726292 2-s2.0-85125447660 https://repository.li.mahidol.ac.th/handle/123456789/74586 Mahidol University SCOPUS https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85125447660&origin=inward
institution Mahidol University
building Mahidol University Library
continent Asia
country Thailand
Thailand
content_provider Mahidol University Library
collection Mahidol University Institutional Repository
topic Medicine
spellingShingle Medicine
Natcha Soontornmanokati
Chulaporn Sirikhamkorn
Nilubon Methachittiphan
Kumpol Chintanavilas
Sanatcha Apakuppakul
Tachapong Ngarmukos
Sirin Apiyasawat
Wachara Lohawijarn
Pakorn Chandanamattha
Transvenous Lead Extraction (TLE) Procedure: Experience from a Tertiary Care Center in Thailand
description Background: Transvenous Lead Extraction (TLE) is a standard treatment for some late Cardiac Implantable Electronics Device (CIED) complications. The outcome of transvenous lead extraction procedure in Thailand is not robust. Methods: A Single-center retrospective cohort of TLE procedures performed at Ramathibodi hospital between January 2008 and December 2020 was studied. Results: There were 157 leads from 105 patients who underwent lead removal procedure during the specified period. Data analysis was performed from 79 TLE patients due to incomplete data and lead explant procedure of the excluded subjects. Mean patients’ age was 57.7 ± 18.7 years, with 70.9% male. There were 82 pacemaker leads, 35 ICD leads, and 5 CS leads (mean number of leads were 1.54 ± 0.66 per patient), with mean implanted duration of 87.8 ± 68.2 months. Main indication for TLE was infection-related, which accounted for 67.1% of the cases. Overall clinical success rate was 97.5%. Mean operative time was 163.8 ± 69.5 min. Major complications occurred in 4 patients (5.1%) with one in-hospital mortality from severe sepsis. Conclusion: TLE using laser sheath and rotating mechanical sheath for transvenous lead extraction is effective and safe, even outside high-volume center.
author2 Faculty of Medicine Ramathibodi Hospital, Mahidol University
author_facet Faculty of Medicine Ramathibodi Hospital, Mahidol University
Natcha Soontornmanokati
Chulaporn Sirikhamkorn
Nilubon Methachittiphan
Kumpol Chintanavilas
Sanatcha Apakuppakul
Tachapong Ngarmukos
Sirin Apiyasawat
Wachara Lohawijarn
Pakorn Chandanamattha
format Article
author Natcha Soontornmanokati
Chulaporn Sirikhamkorn
Nilubon Methachittiphan
Kumpol Chintanavilas
Sanatcha Apakuppakul
Tachapong Ngarmukos
Sirin Apiyasawat
Wachara Lohawijarn
Pakorn Chandanamattha
author_sort Natcha Soontornmanokati
title Transvenous Lead Extraction (TLE) Procedure: Experience from a Tertiary Care Center in Thailand
title_short Transvenous Lead Extraction (TLE) Procedure: Experience from a Tertiary Care Center in Thailand
title_full Transvenous Lead Extraction (TLE) Procedure: Experience from a Tertiary Care Center in Thailand
title_fullStr Transvenous Lead Extraction (TLE) Procedure: Experience from a Tertiary Care Center in Thailand
title_full_unstemmed Transvenous Lead Extraction (TLE) Procedure: Experience from a Tertiary Care Center in Thailand
title_sort transvenous lead extraction (tle) procedure: experience from a tertiary care center in thailand
publishDate 2022
url https://repository.li.mahidol.ac.th/handle/123456789/74586
_version_ 1763497559934894080