Customized treatment using microfocused ultrasound with visualization for optimized patient outcomes: A review of skin-tightening energy technologies and a pan-asian adaptation of the expert panel's gold standard consensus
BACKGROUND: Noninvasive facial-rejuvenation devices, such as nonablative radiofrequency (RF) and laser-assisted technology, are increasingly replacing higher-risk surgeries for face and body skin laxity. OBJECTIVE: We sought to review published information on noninvasive energy device safety and eff...
Saved in:
Main Authors: | , , , , , , , , , , , , |
---|---|
Other Authors: | |
Format: | Review |
Published: |
2022
|
Subjects: | |
Online Access: | https://repository.li.mahidol.ac.th/handle/123456789/78209 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Mahidol University |
id |
th-mahidol.78209 |
---|---|
record_format |
dspace |
spelling |
th-mahidol.782092022-08-04T16:24:25Z Customized treatment using microfocused ultrasound with visualization for optimized patient outcomes: A review of skin-tightening energy technologies and a pan-asian adaptation of the expert panel's gold standard consensus JE YOUNG PARK FRANK LIN ATCHIMA SUWANCHINDA RUNGSIMA WANITPHAKDEEDECHA JONATHAN YU TING SONG LIM JENG FENG CHEN WILSON HO JOYCE LIM LANNY JUNIARTY YONG SENG KEE SEONG JAE YOUN SABRINA FABI Siriraj Hospital Department of Dermatology Box Hill Hospital Premier Clinic Miracle Aesthetic Clinic Clique Clinic Beauté J'adore Dermatology and Esthetic Medicine in Taipei Oracle Dermatology Center Medisci Biointegrative and Antiaging and Cosmetic Medical Center in Bangkok Joyce Lim Skin and Laser Clinic JY Dermatology and Aesthetic Center ARC Plastic Surgery Leaders Clinic Division of Plastic, Reconstructive and Aesthetic Surgery Medicine BACKGROUND: Noninvasive facial-rejuvenation devices, such as nonablative radiofrequency (RF) and laser-assisted technology, are increasingly replacing higher-risk surgeries for face and body skin laxity. OBJECTIVE: We sought to review published information on noninvasive energy device safety and efficacy in aesthetic skin tightening, compare these with our experiences in Asian patients, and disseminate a consensus for optimizing microfocused ultrasound with visualization (MFU-V) in Asian patients. METHODS: A broad, nonexhaustive, nonsystematic literature search of published studies indexed in PubMed was performed to compare selected energy technologies to MFU-V for noninvasive face and body skin tightening, in particular, among Asian patients. This was supplemented with internal documents to provide evidence and support arguments if no peer-reviewed data were available. RESULTS:We highlighted the differences between devices and platforms and identified factors requiring attention and caution. Due to the increase in new devices lacking strong supporting clinical evidence of both safety and efficacy in Asia, it is necessary to convene physicians with substantial experience in MFU-V and devise a consensus on Asian patient selection, treatment planning, and customization. CONCLUSION: Many platforms duplicate or claim similar technologies, efficacy, or safety without significant peer-reviewed scientific or clinical evidence. We showed that MFU-V satisfies this clinical imperative. Further, the patented DeepSEE® technology allows users to noninvasively "see" through the skin to ensure treatment precision, facilitate optimal skin lifting and tightening, and enhance patient comfort and safety. Therefore, we believe that MFU-V is the gold standard for nonsurgical lifting and skin tightening. 2022-08-04T09:24:25Z 2022-08-04T09:24:25Z 2021-05-01 Review Journal of Clinical and Aesthetic Dermatology. Vol.14, No.5 (2021), E70-E79 19412789 2-s2.0-85113435774 https://repository.li.mahidol.ac.th/handle/123456789/78209 Mahidol University SCOPUS https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85113435774&origin=inward |
institution |
Mahidol University |
building |
Mahidol University Library |
continent |
Asia |
country |
Thailand Thailand |
content_provider |
Mahidol University Library |
collection |
Mahidol University Institutional Repository |
topic |
Medicine |
spellingShingle |
Medicine JE YOUNG PARK FRANK LIN ATCHIMA SUWANCHINDA RUNGSIMA WANITPHAKDEEDECHA JONATHAN YU TING SONG LIM JENG FENG CHEN WILSON HO JOYCE LIM LANNY JUNIARTY YONG SENG KEE SEONG JAE YOUN SABRINA FABI Customized treatment using microfocused ultrasound with visualization for optimized patient outcomes: A review of skin-tightening energy technologies and a pan-asian adaptation of the expert panel's gold standard consensus |
description |
BACKGROUND: Noninvasive facial-rejuvenation devices, such as nonablative radiofrequency (RF) and laser-assisted technology, are increasingly replacing higher-risk surgeries for face and body skin laxity. OBJECTIVE: We sought to review published information on noninvasive energy device safety and efficacy in aesthetic skin tightening, compare these with our experiences in Asian patients, and disseminate a consensus for optimizing microfocused ultrasound with visualization (MFU-V) in Asian patients. METHODS: A broad, nonexhaustive, nonsystematic literature search of published studies indexed in PubMed was performed to compare selected energy technologies to MFU-V for noninvasive face and body skin tightening, in particular, among Asian patients. This was supplemented with internal documents to provide evidence and support arguments if no peer-reviewed data were available. RESULTS:We highlighted the differences between devices and platforms and identified factors requiring attention and caution. Due to the increase in new devices lacking strong supporting clinical evidence of both safety and efficacy in Asia, it is necessary to convene physicians with substantial experience in MFU-V and devise a consensus on Asian patient selection, treatment planning, and customization. CONCLUSION: Many platforms duplicate or claim similar technologies, efficacy, or safety without significant peer-reviewed scientific or clinical evidence. We showed that MFU-V satisfies this clinical imperative. Further, the patented DeepSEE® technology allows users to noninvasively "see" through the skin to ensure treatment precision, facilitate optimal skin lifting and tightening, and enhance patient comfort and safety. Therefore, we believe that MFU-V is the gold standard for nonsurgical lifting and skin tightening. |
author2 |
Siriraj Hospital |
author_facet |
Siriraj Hospital JE YOUNG PARK FRANK LIN ATCHIMA SUWANCHINDA RUNGSIMA WANITPHAKDEEDECHA JONATHAN YU TING SONG LIM JENG FENG CHEN WILSON HO JOYCE LIM LANNY JUNIARTY YONG SENG KEE SEONG JAE YOUN SABRINA FABI |
format |
Review |
author |
JE YOUNG PARK FRANK LIN ATCHIMA SUWANCHINDA RUNGSIMA WANITPHAKDEEDECHA JONATHAN YU TING SONG LIM JENG FENG CHEN WILSON HO JOYCE LIM LANNY JUNIARTY YONG SENG KEE SEONG JAE YOUN SABRINA FABI |
author_sort |
JE YOUNG PARK |
title |
Customized treatment using microfocused ultrasound with visualization for optimized patient outcomes: A review of skin-tightening energy technologies and a pan-asian adaptation of the expert panel's gold standard consensus |
title_short |
Customized treatment using microfocused ultrasound with visualization for optimized patient outcomes: A review of skin-tightening energy technologies and a pan-asian adaptation of the expert panel's gold standard consensus |
title_full |
Customized treatment using microfocused ultrasound with visualization for optimized patient outcomes: A review of skin-tightening energy technologies and a pan-asian adaptation of the expert panel's gold standard consensus |
title_fullStr |
Customized treatment using microfocused ultrasound with visualization for optimized patient outcomes: A review of skin-tightening energy technologies and a pan-asian adaptation of the expert panel's gold standard consensus |
title_full_unstemmed |
Customized treatment using microfocused ultrasound with visualization for optimized patient outcomes: A review of skin-tightening energy technologies and a pan-asian adaptation of the expert panel's gold standard consensus |
title_sort |
customized treatment using microfocused ultrasound with visualization for optimized patient outcomes: a review of skin-tightening energy technologies and a pan-asian adaptation of the expert panel's gold standard consensus |
publishDate |
2022 |
url |
https://repository.li.mahidol.ac.th/handle/123456789/78209 |
_version_ |
1763490357455093760 |