Colorimetric pad for low-concentration formaldehyde monitoring in indoor air

Purpose: The purpose of this study was to develop an accurate, selective, low-cost and user-friendly colorimetric pad to detect formaldehyde at low concentration. Design/methodology/approach: 1-phenyl-1,3-butanedione, a reactive chemical, was selected to develop the colorimetric pad for indoor air f...

Full description

Saved in:
Bibliographic Details
Main Author: Wongsakoonkan W.
Other Authors: Mahidol University
Format: Article
Published: 2023
Subjects:
Online Access:https://repository.li.mahidol.ac.th/handle/123456789/85724
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Mahidol University
id th-mahidol.85724
record_format dspace
spelling th-mahidol.857242023-06-19T00:47:34Z Colorimetric pad for low-concentration formaldehyde monitoring in indoor air Wongsakoonkan W. Mahidol University Medicine Purpose: The purpose of this study was to develop an accurate, selective, low-cost and user-friendly colorimetric pad to detect formaldehyde at low concentration. Design/methodology/approach: 1-phenyl-1,3-butanedione, a reactive chemical, was selected to develop the colorimetric pad for indoor air formaldehyde measurement. Silica nanoparticle impregnated with the reactive chemical was coated on the cellulose filter surface to increase the reactive site. A certified formaldehyde permeation tube was used to generate six varied concentrations between 0.01 and 0.10 ppm in a test chamber. The color intensity on the pads was measured using an image processing program to produce a formaldehyde concentration reading chart. The colorimetric pad was tested for optimum reaction time, accuracy, precision, stability, selectivity and shelf life. Findings: The color of the pads changed from white to yellow and the color intensity varied with the concentrations and appeared to be stable after exposure to formaldehyde for 8 hours. At room temperature, the stability of the pad was 7 days, and shelf life was 120 days. The accuracy, precision and bias of the pad were 12.38%, 0.032 and 6.0%, respectively. Carbonyl compounds, benzene and toluene did not interfere with the reading of this developed colorimetric pad. Originality/value: The developed colorimetric pad meets NIOSH's criteria for an overall accuracy of ±25%, bias = 10%. They were accurate at low concentrations, user-friendly and had low cost compared to an electronic direct reading instrument (cost of chemicals and materials was 21.50 Bath or 0.69 USD per piece) so that favorable for the use of general people for health protection. 2023-06-18T17:47:34Z 2023-06-18T17:47:34Z 2022-07-04 Article Journal of Health Research Vol.36 No.4 (2022) , 781-790 10.1108/JHR-09-2020-0428 2586940X 08574421 2-s2.0-85115816906 https://repository.li.mahidol.ac.th/handle/123456789/85724 SCOPUS
institution Mahidol University
building Mahidol University Library
continent Asia
country Thailand
Thailand
content_provider Mahidol University Library
collection Mahidol University Institutional Repository
topic Medicine
spellingShingle Medicine
Wongsakoonkan W.
Colorimetric pad for low-concentration formaldehyde monitoring in indoor air
description Purpose: The purpose of this study was to develop an accurate, selective, low-cost and user-friendly colorimetric pad to detect formaldehyde at low concentration. Design/methodology/approach: 1-phenyl-1,3-butanedione, a reactive chemical, was selected to develop the colorimetric pad for indoor air formaldehyde measurement. Silica nanoparticle impregnated with the reactive chemical was coated on the cellulose filter surface to increase the reactive site. A certified formaldehyde permeation tube was used to generate six varied concentrations between 0.01 and 0.10 ppm in a test chamber. The color intensity on the pads was measured using an image processing program to produce a formaldehyde concentration reading chart. The colorimetric pad was tested for optimum reaction time, accuracy, precision, stability, selectivity and shelf life. Findings: The color of the pads changed from white to yellow and the color intensity varied with the concentrations and appeared to be stable after exposure to formaldehyde for 8 hours. At room temperature, the stability of the pad was 7 days, and shelf life was 120 days. The accuracy, precision and bias of the pad were 12.38%, 0.032 and 6.0%, respectively. Carbonyl compounds, benzene and toluene did not interfere with the reading of this developed colorimetric pad. Originality/value: The developed colorimetric pad meets NIOSH's criteria for an overall accuracy of ±25%, bias = 10%. They were accurate at low concentrations, user-friendly and had low cost compared to an electronic direct reading instrument (cost of chemicals and materials was 21.50 Bath or 0.69 USD per piece) so that favorable for the use of general people for health protection.
author2 Mahidol University
author_facet Mahidol University
Wongsakoonkan W.
format Article
author Wongsakoonkan W.
author_sort Wongsakoonkan W.
title Colorimetric pad for low-concentration formaldehyde monitoring in indoor air
title_short Colorimetric pad for low-concentration formaldehyde monitoring in indoor air
title_full Colorimetric pad for low-concentration formaldehyde monitoring in indoor air
title_fullStr Colorimetric pad for low-concentration formaldehyde monitoring in indoor air
title_full_unstemmed Colorimetric pad for low-concentration formaldehyde monitoring in indoor air
title_sort colorimetric pad for low-concentration formaldehyde monitoring in indoor air
publishDate 2023
url https://repository.li.mahidol.ac.th/handle/123456789/85724
_version_ 1781414299735949312