Accuracy of capillary blood glucose for 50-g glucose challenge test for gestational diabetes screening
Purpose: To assess the accuracy of capillary blood glucose (CBG) compared to conventional venous plasma glucose (VPG) testing for 50-g glucose challenge test (GCT) in gestational diabetes (GDM) screening. Methods: A total of 300 women were enrolled and 50-g GCT for GDM screening was offered. At 1 h...