Application of QuantiFERON ELISA for Detection of Interferon-Gamma Autoantibodies in Adult-Onset Immunodeficiency Syndrome

Objective: Patients who develop interferon-gamma autoantibodies (IFN-γ autoAbs) in adult-onset immunodeficiency (AOID) syndrome are more likely to develop opportunistic and recurrent intracellular infections. The assay to detect IFN-γ autoAbs is essential for the diagnosis and therapeutic monitoring...

Full description

Saved in:
Bibliographic Details
Main Author: Khositnithikul R.
Other Authors: Mahidol University
Format: Article
Published: 2023
Subjects:
Online Access:https://repository.li.mahidol.ac.th/handle/123456789/86700
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Mahidol University
id th-mahidol.86700
record_format dspace
spelling th-mahidol.867002023-06-19T01:07:57Z Application of QuantiFERON ELISA for Detection of Interferon-Gamma Autoantibodies in Adult-Onset Immunodeficiency Syndrome Khositnithikul R. Mahidol University Medicine Objective: Patients who develop interferon-gamma autoantibodies (IFN-γ autoAbs) in adult-onset immunodeficiency (AOID) syndrome are more likely to develop opportunistic and recurrent intracellular infections. The assay to detect IFN-γ autoAbs is essential for the diagnosis and therapeutic monitoring of AOID syndrome. Therefore, this study applied the QuantiFERON assay for the detection of IFN-γ autoAbs. Methods: Serum from patients with AOID syndrome (n = 19) and serum from healthy patients (n = 20) was collected and applied using 2 neutralizing platforms of enzyme-linked immunosorbent assay (ELISA) kits (the BD ELISA and the QuantiFERON ELISA) for IFN-γ autoAbs detection. Results: The pooled serum from patients with AOID syndrome showed >50% inhibition at 1:5000 dilution (positive), whereas the pooled serum from healthy patients showed <50% inhibition at 1:5000 dilution (negative) according to the neutralizing QuantiFERON ELISA. Each specimen showed the same result according to both the neutralizing BD ELISA and the neutralizing QuantiFERON ELISA. Moreover, the patient serum showed a variation in titer ranging from 1:5000 to >1:5,000,000 according to the neutralizing QuantiFERON ELISA. Conclusion: The QuantiFERON ELISA kit could be applied for the detection of IFN-γ autoAbs for the diagnosis and therapeutic monitoring of AOID syndrome. 2023-06-18T18:07:57Z 2023-06-18T18:07:57Z 2022-01-01 Article Lab Medicine Vol.53 No.1 (2022) , 12-17 10.1093/labmed/lmab039 19437730 00075027 34463313 2-s2.0-85123389813 https://repository.li.mahidol.ac.th/handle/123456789/86700 SCOPUS
institution Mahidol University
building Mahidol University Library
continent Asia
country Thailand
Thailand
content_provider Mahidol University Library
collection Mahidol University Institutional Repository
topic Medicine
spellingShingle Medicine
Khositnithikul R.
Application of QuantiFERON ELISA for Detection of Interferon-Gamma Autoantibodies in Adult-Onset Immunodeficiency Syndrome
description Objective: Patients who develop interferon-gamma autoantibodies (IFN-γ autoAbs) in adult-onset immunodeficiency (AOID) syndrome are more likely to develop opportunistic and recurrent intracellular infections. The assay to detect IFN-γ autoAbs is essential for the diagnosis and therapeutic monitoring of AOID syndrome. Therefore, this study applied the QuantiFERON assay for the detection of IFN-γ autoAbs. Methods: Serum from patients with AOID syndrome (n = 19) and serum from healthy patients (n = 20) was collected and applied using 2 neutralizing platforms of enzyme-linked immunosorbent assay (ELISA) kits (the BD ELISA and the QuantiFERON ELISA) for IFN-γ autoAbs detection. Results: The pooled serum from patients with AOID syndrome showed >50% inhibition at 1:5000 dilution (positive), whereas the pooled serum from healthy patients showed <50% inhibition at 1:5000 dilution (negative) according to the neutralizing QuantiFERON ELISA. Each specimen showed the same result according to both the neutralizing BD ELISA and the neutralizing QuantiFERON ELISA. Moreover, the patient serum showed a variation in titer ranging from 1:5000 to >1:5,000,000 according to the neutralizing QuantiFERON ELISA. Conclusion: The QuantiFERON ELISA kit could be applied for the detection of IFN-γ autoAbs for the diagnosis and therapeutic monitoring of AOID syndrome.
author2 Mahidol University
author_facet Mahidol University
Khositnithikul R.
format Article
author Khositnithikul R.
author_sort Khositnithikul R.
title Application of QuantiFERON ELISA for Detection of Interferon-Gamma Autoantibodies in Adult-Onset Immunodeficiency Syndrome
title_short Application of QuantiFERON ELISA for Detection of Interferon-Gamma Autoantibodies in Adult-Onset Immunodeficiency Syndrome
title_full Application of QuantiFERON ELISA for Detection of Interferon-Gamma Autoantibodies in Adult-Onset Immunodeficiency Syndrome
title_fullStr Application of QuantiFERON ELISA for Detection of Interferon-Gamma Autoantibodies in Adult-Onset Immunodeficiency Syndrome
title_full_unstemmed Application of QuantiFERON ELISA for Detection of Interferon-Gamma Autoantibodies in Adult-Onset Immunodeficiency Syndrome
title_sort application of quantiferon elisa for detection of interferon-gamma autoantibodies in adult-onset immunodeficiency syndrome
publishDate 2023
url https://repository.li.mahidol.ac.th/handle/123456789/86700
_version_ 1781415022914699264