Corrigendum to “Performance test of the electromagnetic particle detectors for the LHAASO experiment” [Nucl. Instrum. Methods Phys. Res. A 1001 (2021) 165193] (Nuclear Inst. and Methods in Physics Research, A (2021) 1001, (S0168900221001777), (10.1016/j.nima.2021.165193))

The authors regret < (1) In the abstract: “[Formula presented] charge resolution for single particle of 18.5% and [Formula presented]” change to “[Formula presented]charge resolution for single particle of 22.2% and [Formula presented]” (2) Fig. 11 shows distribution of charge resolution of 4362E...

Full description

Saved in:
Bibliographic Details
Main Author: Aharonian F.
Other Authors: Mahidol University
Format: Erratum
Published: 2023
Subjects:
Online Access:https://repository.li.mahidol.ac.th/handle/123456789/87588
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Mahidol University
id th-mahidol.87588
record_format dspace
spelling th-mahidol.875882023-06-22T18:22:16Z Corrigendum to “Performance test of the electromagnetic particle detectors for the LHAASO experiment” [Nucl. Instrum. Methods Phys. Res. A 1001 (2021) 165193] (Nuclear Inst. and Methods in Physics Research, A (2021) 1001, (S0168900221001777), (10.1016/j.nima.2021.165193)) Aharonian F. Mahidol University Physics and Astronomy The authors regret < (1) In the abstract: “[Formula presented] charge resolution for single particle of 18.5% and [Formula presented]” change to “[Formula presented]charge resolution for single particle of 22.2% and [Formula presented]” (2) Fig. 11 shows distribution of charge resolution of 4362EDs, this figure should be replaced with the followed figure. [Figure presented] (3) In the conclusion: “The charge resolution for single-track events of all tested EDs is about 18.5%”. – change to – “The charge resolution for single-track events of all tested EDs is about 22.2%”. >. The authors would like to apologize for any inconvenience caused. We are sorry that there is a mistake in the paper of “Performance test of the electromagnetic particle detectors for the LHAASO experiment”. That is the figure 11 was submitted by mistake. During the ED's performance test, the definition of charge resolution of single particle developed a little bit which brought confusions. In the beginning, we define [Formula presented], where MPV is the maximum of the fitted function. Then we use [Formula presented], however it is relate to the range of spectrum. Finally, we use [Formula presented], where, [Formula presented] using a Gaussian approximation in the paper. Figures of the charge resolution with these definitions were stored in the same directory. Thus, a wrong figure was uploaded during the paper submission. We are very sorry that our negligence causing inconvenience to everyone. 2023-06-22T11:22:16Z 2023-06-22T11:22:16Z 2022-01-11 Erratum Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment Vol.1022 (2022) 10.1016/j.nima.2021.165986 01689002 2-s2.0-85119044986 https://repository.li.mahidol.ac.th/handle/123456789/87588 SCOPUS
institution Mahidol University
building Mahidol University Library
continent Asia
country Thailand
Thailand
content_provider Mahidol University Library
collection Mahidol University Institutional Repository
topic Physics and Astronomy
spellingShingle Physics and Astronomy
Aharonian F.
Corrigendum to “Performance test of the electromagnetic particle detectors for the LHAASO experiment” [Nucl. Instrum. Methods Phys. Res. A 1001 (2021) 165193] (Nuclear Inst. and Methods in Physics Research, A (2021) 1001, (S0168900221001777), (10.1016/j.nima.2021.165193))
description The authors regret < (1) In the abstract: “[Formula presented] charge resolution for single particle of 18.5% and [Formula presented]” change to “[Formula presented]charge resolution for single particle of 22.2% and [Formula presented]” (2) Fig. 11 shows distribution of charge resolution of 4362EDs, this figure should be replaced with the followed figure. [Figure presented] (3) In the conclusion: “The charge resolution for single-track events of all tested EDs is about 18.5%”. – change to – “The charge resolution for single-track events of all tested EDs is about 22.2%”. >. The authors would like to apologize for any inconvenience caused. We are sorry that there is a mistake in the paper of “Performance test of the electromagnetic particle detectors for the LHAASO experiment”. That is the figure 11 was submitted by mistake. During the ED's performance test, the definition of charge resolution of single particle developed a little bit which brought confusions. In the beginning, we define [Formula presented], where MPV is the maximum of the fitted function. Then we use [Formula presented], however it is relate to the range of spectrum. Finally, we use [Formula presented], where, [Formula presented] using a Gaussian approximation in the paper. Figures of the charge resolution with these definitions were stored in the same directory. Thus, a wrong figure was uploaded during the paper submission. We are very sorry that our negligence causing inconvenience to everyone.
author2 Mahidol University
author_facet Mahidol University
Aharonian F.
format Erratum
author Aharonian F.
author_sort Aharonian F.
title Corrigendum to “Performance test of the electromagnetic particle detectors for the LHAASO experiment” [Nucl. Instrum. Methods Phys. Res. A 1001 (2021) 165193] (Nuclear Inst. and Methods in Physics Research, A (2021) 1001, (S0168900221001777), (10.1016/j.nima.2021.165193))
title_short Corrigendum to “Performance test of the electromagnetic particle detectors for the LHAASO experiment” [Nucl. Instrum. Methods Phys. Res. A 1001 (2021) 165193] (Nuclear Inst. and Methods in Physics Research, A (2021) 1001, (S0168900221001777), (10.1016/j.nima.2021.165193))
title_full Corrigendum to “Performance test of the electromagnetic particle detectors for the LHAASO experiment” [Nucl. Instrum. Methods Phys. Res. A 1001 (2021) 165193] (Nuclear Inst. and Methods in Physics Research, A (2021) 1001, (S0168900221001777), (10.1016/j.nima.2021.165193))
title_fullStr Corrigendum to “Performance test of the electromagnetic particle detectors for the LHAASO experiment” [Nucl. Instrum. Methods Phys. Res. A 1001 (2021) 165193] (Nuclear Inst. and Methods in Physics Research, A (2021) 1001, (S0168900221001777), (10.1016/j.nima.2021.165193))
title_full_unstemmed Corrigendum to “Performance test of the electromagnetic particle detectors for the LHAASO experiment” [Nucl. Instrum. Methods Phys. Res. A 1001 (2021) 165193] (Nuclear Inst. and Methods in Physics Research, A (2021) 1001, (S0168900221001777), (10.1016/j.nima.2021.165193))
title_sort corrigendum to “performance test of the electromagnetic particle detectors for the lhaaso experiment” [nucl. instrum. methods phys. res. a 1001 (2021) 165193] (nuclear inst. and methods in physics research, a (2021) 1001, (s0168900221001777), (10.1016/j.nima.2021.165193))
publishDate 2023
url https://repository.li.mahidol.ac.th/handle/123456789/87588
_version_ 1781414025529131008