INDIUM TIN OXIDE MICRO-ELECTRODE ARRAY FOR NEURONAL STIMULTION AND RECORDING

Influence of applied electric field on biological cells has been widely investigated particularly for medical application, for example, to stimulate excitable neurons. Indium tin oxide (ITO), a transparent conducting semiconductor with biocompatible property, is used for electrical stimulating and e...

Full description

Saved in:
Bibliographic Details
Main Author: Udomrat S.
Other Authors: Mahidol University
Format: Article
Published: 2023
Subjects:
Online Access:https://repository.li.mahidol.ac.th/handle/123456789/87780
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Mahidol University
id th-mahidol.87780
record_format dspace
spelling th-mahidol.877802023-07-08T01:01:46Z INDIUM TIN OXIDE MICRO-ELECTRODE ARRAY FOR NEURONAL STIMULTION AND RECORDING Udomrat S. Mahidol University Engineering Influence of applied electric field on biological cells has been widely investigated particularly for medical application, for example, to stimulate excitable neurons. Indium tin oxide (ITO), a transparent conducting semiconductor with biocompatible property, is used for electrical stimulating and electrochemical sensing the cell on the platform. In this work, ITO platform was developed by lithography micron-patterning and modified surface with protein coating. Surface morphology of the treated ITO surface was examined and biocompatibility was investigated by long period cell culture. SH-SY5Y, a human-neuroblastoma, was grown and subjected to 50 mV/ mm of steady state direct current electric field applying through the protein functionalized ITO platform for 30 min. The electrical treated cells exhibited morphological changes by extending neuronal processes length to 10. 75±30. 96 μm (n = 43) longer than the non-electrical treated cells. After electrical treatment, cell alignment following the electric field direction can also be observed. This work can demonstrate the biocompatibility and possibility use of treated ITO electrode for inducing cells morphological changes and controlling cell alignment. Furthermore, the fabricated ITO electrode can also demonstrate additional benefit of observing cellular activity by the means of electrical signal detection during the cellular progressions. 2023-07-07T18:01:46Z 2023-07-07T18:01:46Z 2022-01-01 Article Suranaree Journal of Science and Technology Vol.29 No.1 (2022) 25870009 0858849X 2-s2.0-85130594145 https://repository.li.mahidol.ac.th/handle/123456789/87780 SCOPUS
institution Mahidol University
building Mahidol University Library
continent Asia
country Thailand
Thailand
content_provider Mahidol University Library
collection Mahidol University Institutional Repository
topic Engineering
spellingShingle Engineering
Udomrat S.
INDIUM TIN OXIDE MICRO-ELECTRODE ARRAY FOR NEURONAL STIMULTION AND RECORDING
description Influence of applied electric field on biological cells has been widely investigated particularly for medical application, for example, to stimulate excitable neurons. Indium tin oxide (ITO), a transparent conducting semiconductor with biocompatible property, is used for electrical stimulating and electrochemical sensing the cell on the platform. In this work, ITO platform was developed by lithography micron-patterning and modified surface with protein coating. Surface morphology of the treated ITO surface was examined and biocompatibility was investigated by long period cell culture. SH-SY5Y, a human-neuroblastoma, was grown and subjected to 50 mV/ mm of steady state direct current electric field applying through the protein functionalized ITO platform for 30 min. The electrical treated cells exhibited morphological changes by extending neuronal processes length to 10. 75±30. 96 μm (n = 43) longer than the non-electrical treated cells. After electrical treatment, cell alignment following the electric field direction can also be observed. This work can demonstrate the biocompatibility and possibility use of treated ITO electrode for inducing cells morphological changes and controlling cell alignment. Furthermore, the fabricated ITO electrode can also demonstrate additional benefit of observing cellular activity by the means of electrical signal detection during the cellular progressions.
author2 Mahidol University
author_facet Mahidol University
Udomrat S.
format Article
author Udomrat S.
author_sort Udomrat S.
title INDIUM TIN OXIDE MICRO-ELECTRODE ARRAY FOR NEURONAL STIMULTION AND RECORDING
title_short INDIUM TIN OXIDE MICRO-ELECTRODE ARRAY FOR NEURONAL STIMULTION AND RECORDING
title_full INDIUM TIN OXIDE MICRO-ELECTRODE ARRAY FOR NEURONAL STIMULTION AND RECORDING
title_fullStr INDIUM TIN OXIDE MICRO-ELECTRODE ARRAY FOR NEURONAL STIMULTION AND RECORDING
title_full_unstemmed INDIUM TIN OXIDE MICRO-ELECTRODE ARRAY FOR NEURONAL STIMULTION AND RECORDING
title_sort indium tin oxide micro-electrode array for neuronal stimultion and recording
publishDate 2023
url https://repository.li.mahidol.ac.th/handle/123456789/87780
_version_ 1781413986603892736