Perioperative blood loss reduction using a sterile exsanguination tourniquet for orthopedic femoral-related surgeries in children: a randomized controlled study

OBJECTIVES: The sterile exsanguination tourniquet (SET) could be an alternative for providing bloodless surgeries in orthopedic femoral-related surgeries in pediatric patients where the standard pneumatic tourniquet would not be feasible. This randomized-controlled study aimed to evaluate the effica...

Full description

Saved in:
Bibliographic Details
Main Author: Rattanathanya T.
Other Authors: Mahidol University
Format: Article
Published: 2023
Subjects:
Online Access:https://repository.li.mahidol.ac.th/handle/123456789/88354
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Mahidol University
id th-mahidol.88354
record_format dspace
spelling th-mahidol.883542023-08-18T01:02:07Z Perioperative blood loss reduction using a sterile exsanguination tourniquet for orthopedic femoral-related surgeries in children: a randomized controlled study Rattanathanya T. Mahidol University Medicine OBJECTIVES: The sterile exsanguination tourniquet (SET) could be an alternative for providing bloodless surgeries in orthopedic femoral-related surgeries in pediatric patients where the standard pneumatic tourniquet would not be feasible. This randomized-controlled study aimed to evaluate the efficacy of SET in decreasing total perioperative blood loss and blood transfusion. METHODS: We conducted an unplanned interim analysis of data from a randomized-controlled trial. At the time of the analysis, 31 pediatric patients had been randomly assigned to undergo surgery with the SET application (the SET group, 15 patients) and without the SET application (the control group, 16 patients). An intention-to-treat analysis was performed to evaluate the total perioperative blood loss, postoperative blood transfusion, estimated intraoperative blood loss, total drainage volume, postoperative hemoglobin level, and operative time according to the significance level adjusted for multiplicity (p < 0.029). RESULTS: There was a borderline statistically significant lower body weight-adjusted TBL in the SET group (SET = 14.1 (7.7, 16.9) ml/kg vs. control 18.3 (14.8, 37.2) ml/kg, p-value = 0.027). The body weight-adjusted transfusion volume was statistically significantly greater in the control group (SET = 0.0 (0.0, 0.0) ml/kg vs. control = 2.1 (0.0, 9.7) ml/kg, p = 0.017). Body weight-adjusted estimated intraoperative blood loss was significantly lower in the SET group (SET = 0.8 (0.2, 3.5) ml/kg vs. control = 5.6 (3.4, 21.5) ml/kg, p < 0.001). In addition, the operative time was lower in the SET group with borderline statistical significance (SET = 105 (85.0, 125.0) vs. control = 130 (101.3, 167.5), p =  0.039). CONCLUSION: Utilization of a sterile exsanguination tourniquet (SET) significantly reduced an estimated intraoperative blood loss while preventing the need for blood transfusion after pediatric orthopedic femoral-related surgeries. Trial registration TCTR20220412003. 2023-08-17T18:02:07Z 2023-08-17T18:02:07Z 2023-08-08 Article Journal of orthopaedic surgery and research Vol.18 No.1 (2023) , 580 10.1186/s13018-023-04046-3 1749799X 37553565 2-s2.0-85167370110 https://repository.li.mahidol.ac.th/handle/123456789/88354 SCOPUS
institution Mahidol University
building Mahidol University Library
continent Asia
country Thailand
Thailand
content_provider Mahidol University Library
collection Mahidol University Institutional Repository
topic Medicine
spellingShingle Medicine
Rattanathanya T.
Perioperative blood loss reduction using a sterile exsanguination tourniquet for orthopedic femoral-related surgeries in children: a randomized controlled study
description OBJECTIVES: The sterile exsanguination tourniquet (SET) could be an alternative for providing bloodless surgeries in orthopedic femoral-related surgeries in pediatric patients where the standard pneumatic tourniquet would not be feasible. This randomized-controlled study aimed to evaluate the efficacy of SET in decreasing total perioperative blood loss and blood transfusion. METHODS: We conducted an unplanned interim analysis of data from a randomized-controlled trial. At the time of the analysis, 31 pediatric patients had been randomly assigned to undergo surgery with the SET application (the SET group, 15 patients) and without the SET application (the control group, 16 patients). An intention-to-treat analysis was performed to evaluate the total perioperative blood loss, postoperative blood transfusion, estimated intraoperative blood loss, total drainage volume, postoperative hemoglobin level, and operative time according to the significance level adjusted for multiplicity (p < 0.029). RESULTS: There was a borderline statistically significant lower body weight-adjusted TBL in the SET group (SET = 14.1 (7.7, 16.9) ml/kg vs. control 18.3 (14.8, 37.2) ml/kg, p-value = 0.027). The body weight-adjusted transfusion volume was statistically significantly greater in the control group (SET = 0.0 (0.0, 0.0) ml/kg vs. control = 2.1 (0.0, 9.7) ml/kg, p = 0.017). Body weight-adjusted estimated intraoperative blood loss was significantly lower in the SET group (SET = 0.8 (0.2, 3.5) ml/kg vs. control = 5.6 (3.4, 21.5) ml/kg, p < 0.001). In addition, the operative time was lower in the SET group with borderline statistical significance (SET = 105 (85.0, 125.0) vs. control = 130 (101.3, 167.5), p =  0.039). CONCLUSION: Utilization of a sterile exsanguination tourniquet (SET) significantly reduced an estimated intraoperative blood loss while preventing the need for blood transfusion after pediatric orthopedic femoral-related surgeries. Trial registration TCTR20220412003.
author2 Mahidol University
author_facet Mahidol University
Rattanathanya T.
format Article
author Rattanathanya T.
author_sort Rattanathanya T.
title Perioperative blood loss reduction using a sterile exsanguination tourniquet for orthopedic femoral-related surgeries in children: a randomized controlled study
title_short Perioperative blood loss reduction using a sterile exsanguination tourniquet for orthopedic femoral-related surgeries in children: a randomized controlled study
title_full Perioperative blood loss reduction using a sterile exsanguination tourniquet for orthopedic femoral-related surgeries in children: a randomized controlled study
title_fullStr Perioperative blood loss reduction using a sterile exsanguination tourniquet for orthopedic femoral-related surgeries in children: a randomized controlled study
title_full_unstemmed Perioperative blood loss reduction using a sterile exsanguination tourniquet for orthopedic femoral-related surgeries in children: a randomized controlled study
title_sort perioperative blood loss reduction using a sterile exsanguination tourniquet for orthopedic femoral-related surgeries in children: a randomized controlled study
publishDate 2023
url https://repository.li.mahidol.ac.th/handle/123456789/88354
_version_ 1781415385406373888