Comparing Ultrasonography and Surface Landmark-Guided Lumbar Puncture in Patients with Obesity and Difficult Anatomy; a Randomized Controlled Trial
Introduction: Previous studies have shown higher lumbar puncture (LP) success rates when using ultrasound guidance. This study aimed to compare the first-attempt success rate of ultrasound-guided LP with blind technique of needle insertion using the palpable spinal surface landmark in patients with...
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Article |
Published: |
2023
|
Subjects: | |
Online Access: | https://repository.li.mahidol.ac.th/handle/123456789/90320 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Mahidol University |
id |
th-mahidol.90320 |
---|---|
record_format |
dspace |
spelling |
th-mahidol.903202023-10-06T01:01:57Z Comparing Ultrasonography and Surface Landmark-Guided Lumbar Puncture in Patients with Obesity and Difficult Anatomy; a Randomized Controlled Trial Sanguanwit P. Mahidol University Medicine Introduction: Previous studies have shown higher lumbar puncture (LP) success rates when using ultrasound guidance. This study aimed to compare the first-attempt success rate of ultrasound-guided LP with blind technique of needle insertion using the palpable spinal surface landmark in patients with obesity or a difficult anatomy. Methods: This prospective randomized controlled study was performed at the emergency department of Ramathibodi Hospital, an academic tertiary university hospital, from August 2015 to July 2016. Results: 40 patients were enrolled (20 surface landmark-guided and 20 ultrasound-guided LPs). 52.5% of the patients were male with the mean age of 60.33 ± 4.24 years. The first-attempt success rate in the ultrasound-guided LP group was significantly higher than the landmarkguided LP group (80% vs. 35%, respectively), with risk difference (RD) of 45.00% (95% confidence interval (CI): 17.72%, 72.28%). This indicated absolute risk reduction and number needed to treat of 45.00% and 2.22, respectively. The median procedural duration required to achieve successful LP in the ultrasound-guided LP group was significantly shorter than the surface landmark-guided LP group (5 [IQR: 3–18]minutes vs. 13.5 [IQR: 5-30] minutes, respectively). Traumatic puncture as a complication occurred less frequently in the ultrasound-guided LP group than the surface landmarkguided LP group with risk ratio (RR) = 0.33 (95% CI: 0.08, 1.46) and RD = -20.00% (95% CI: -44.00%, 4.00%). This indicated absolute risk reduction and number needed to harmof 20.00% and 5.00, respectively. However, the difference was not significant. Conclusion: Using ultrasound to help localize the insertion point before LP increased the first-attempt success rate and improved other LP outcomes in Thai patients with obesity or a difficult anatomy. It also shortened the procedural duration and reduced the incidence of traumatic tap. 2023-10-05T18:01:57Z 2023-10-05T18:01:57Z 2023-01-01 Article Archives of Academic Emergency Medicine Vol.11 No.1 (2023) 10.22037/aaem.v11i1.2026 26454904 2-s2.0-85172374481 https://repository.li.mahidol.ac.th/handle/123456789/90320 SCOPUS |
institution |
Mahidol University |
building |
Mahidol University Library |
continent |
Asia |
country |
Thailand Thailand |
content_provider |
Mahidol University Library |
collection |
Mahidol University Institutional Repository |
topic |
Medicine |
spellingShingle |
Medicine Sanguanwit P. Comparing Ultrasonography and Surface Landmark-Guided Lumbar Puncture in Patients with Obesity and Difficult Anatomy; a Randomized Controlled Trial |
description |
Introduction: Previous studies have shown higher lumbar puncture (LP) success rates when using ultrasound guidance. This study aimed to compare the first-attempt success rate of ultrasound-guided LP with blind technique of needle insertion using the palpable spinal surface landmark in patients with obesity or a difficult anatomy. Methods: This prospective randomized controlled study was performed at the emergency department of Ramathibodi Hospital, an academic tertiary university hospital, from August 2015 to July 2016. Results: 40 patients were enrolled (20 surface landmark-guided and 20 ultrasound-guided LPs). 52.5% of the patients were male with the mean age of 60.33 ± 4.24 years. The first-attempt success rate in the ultrasound-guided LP group was significantly higher than the landmarkguided LP group (80% vs. 35%, respectively), with risk difference (RD) of 45.00% (95% confidence interval (CI): 17.72%, 72.28%). This indicated absolute risk reduction and number needed to treat of 45.00% and 2.22, respectively. The median procedural duration required to achieve successful LP in the ultrasound-guided LP group was significantly shorter than the surface landmark-guided LP group (5 [IQR: 3–18]minutes vs. 13.5 [IQR: 5-30] minutes, respectively). Traumatic puncture as a complication occurred less frequently in the ultrasound-guided LP group than the surface landmarkguided LP group with risk ratio (RR) = 0.33 (95% CI: 0.08, 1.46) and RD = -20.00% (95% CI: -44.00%, 4.00%). This indicated absolute risk reduction and number needed to harmof 20.00% and 5.00, respectively. However, the difference was not significant. Conclusion: Using ultrasound to help localize the insertion point before LP increased the first-attempt success rate and improved other LP outcomes in Thai patients with obesity or a difficult anatomy. It also shortened the procedural duration and reduced the incidence of traumatic tap. |
author2 |
Mahidol University |
author_facet |
Mahidol University Sanguanwit P. |
format |
Article |
author |
Sanguanwit P. |
author_sort |
Sanguanwit P. |
title |
Comparing Ultrasonography and Surface Landmark-Guided Lumbar Puncture in Patients with Obesity and Difficult Anatomy; a Randomized Controlled Trial |
title_short |
Comparing Ultrasonography and Surface Landmark-Guided Lumbar Puncture in Patients with Obesity and Difficult Anatomy; a Randomized Controlled Trial |
title_full |
Comparing Ultrasonography and Surface Landmark-Guided Lumbar Puncture in Patients with Obesity and Difficult Anatomy; a Randomized Controlled Trial |
title_fullStr |
Comparing Ultrasonography and Surface Landmark-Guided Lumbar Puncture in Patients with Obesity and Difficult Anatomy; a Randomized Controlled Trial |
title_full_unstemmed |
Comparing Ultrasonography and Surface Landmark-Guided Lumbar Puncture in Patients with Obesity and Difficult Anatomy; a Randomized Controlled Trial |
title_sort |
comparing ultrasonography and surface landmark-guided lumbar puncture in patients with obesity and difficult anatomy; a randomized controlled trial |
publishDate |
2023 |
url |
https://repository.li.mahidol.ac.th/handle/123456789/90320 |
_version_ |
1781797305515507712 |