Intaglio Surface Adaptation of Removable Partial Denture Framework Fabricated by Various Data Acquisition Techniques and Fabrication Approaches
Objectives The aim of this study was to compare intaglio surface adaptation of the removable partial denture framework among various data acquisition techniques and fabrication approaches using three-dimensional comparison by metrology software. Materials and Methods The partial edentulous typodon...
Saved in:
Main Author: | |
---|---|
Other Authors: | |
Format: | Article |
Published: |
2023
|
Subjects: | |
Online Access: | https://repository.li.mahidol.ac.th/handle/123456789/90566 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Mahidol University |
id |
th-mahidol.90566 |
---|---|
record_format |
dspace |
spelling |
th-mahidol.905662023-10-20T01:01:29Z Intaglio Surface Adaptation of Removable Partial Denture Framework Fabricated by Various Data Acquisition Techniques and Fabrication Approaches Limpiwatana S. Mahidol University Dentistry Objectives The aim of this study was to compare intaglio surface adaptation of the removable partial denture framework among various data acquisition techniques and fabrication approaches using three-dimensional comparison by metrology software. Materials and Methods The partial edentulous typodont model with five digital superimposition landmarks was duplicated and scanned for the digital reference model. Three approaches were the conventional lost-wax (group I; LWT, n = 5), intraoral digital impressions combined with PolyJet printing and lost-wax (group II; IP-LWT, n = 5), and extraoral digital impressions combined with PolyJet printing and lost-wax (group III; EP-LWT, n = 5). Each framework was scanned and superimposed with the reference model. The misfits at 53 locations were measured. Statistical Analysis Data were statistically analyzed by one-way analysis of variance, followed by Tukey's honestly significant difference for pairwise comparisons (p < 0.05). Results Significant differences were found between three approaches at the reciprocal arm, terminal part of the retentive arm, rest, and major connector (p < 0.05). In the LWT group, the reciprocal arm and palatal vault region of major connector had the lowest misfits, but the highest misfit was found in the midline region (p < 0.001). In the IP-LWT group revealed the most excessive contact at the terminal part of the retentive arm (-0.111 ± 0.038 mm, p = 0.031), with the highest misfit at the rest area (p < 0.001). Conclusion A difference in adaptation was found in several removable partial denture framework components among three approaches. The LWT group had a better adaptation than other groups. Nevertheless, a clinically acceptable adaptation was seen in all three approaches. 2023-10-19T18:01:29Z 2023-10-19T18:01:29Z 2023-01-01 Article European Journal of Dentistry (2023) 10.1055/s-0043-1772245 13057464 13057456 2-s2.0-85173427942 https://repository.li.mahidol.ac.th/handle/123456789/90566 SCOPUS |
institution |
Mahidol University |
building |
Mahidol University Library |
continent |
Asia |
country |
Thailand Thailand |
content_provider |
Mahidol University Library |
collection |
Mahidol University Institutional Repository |
topic |
Dentistry |
spellingShingle |
Dentistry Limpiwatana S. Intaglio Surface Adaptation of Removable Partial Denture Framework Fabricated by Various Data Acquisition Techniques and Fabrication Approaches |
description |
Objectives The aim of this study was to compare intaglio surface adaptation of the removable partial denture framework among various data acquisition techniques and fabrication approaches using three-dimensional comparison by metrology software. Materials and Methods The partial edentulous typodont model with five digital superimposition landmarks was duplicated and scanned for the digital reference model. Three approaches were the conventional lost-wax (group I; LWT, n = 5), intraoral digital impressions combined with PolyJet printing and lost-wax (group II; IP-LWT, n = 5), and extraoral digital impressions combined with PolyJet printing and lost-wax (group III; EP-LWT, n = 5). Each framework was scanned and superimposed with the reference model. The misfits at 53 locations were measured. Statistical Analysis Data were statistically analyzed by one-way analysis of variance, followed by Tukey's honestly significant difference for pairwise comparisons (p < 0.05). Results Significant differences were found between three approaches at the reciprocal arm, terminal part of the retentive arm, rest, and major connector (p < 0.05). In the LWT group, the reciprocal arm and palatal vault region of major connector had the lowest misfits, but the highest misfit was found in the midline region (p < 0.001). In the IP-LWT group revealed the most excessive contact at the terminal part of the retentive arm (-0.111 ± 0.038 mm, p = 0.031), with the highest misfit at the rest area (p < 0.001). Conclusion A difference in adaptation was found in several removable partial denture framework components among three approaches. The LWT group had a better adaptation than other groups. Nevertheless, a clinically acceptable adaptation was seen in all three approaches. |
author2 |
Mahidol University |
author_facet |
Mahidol University Limpiwatana S. |
format |
Article |
author |
Limpiwatana S. |
author_sort |
Limpiwatana S. |
title |
Intaglio Surface Adaptation of Removable Partial Denture Framework Fabricated by Various Data Acquisition Techniques and Fabrication Approaches |
title_short |
Intaglio Surface Adaptation of Removable Partial Denture Framework Fabricated by Various Data Acquisition Techniques and Fabrication Approaches |
title_full |
Intaglio Surface Adaptation of Removable Partial Denture Framework Fabricated by Various Data Acquisition Techniques and Fabrication Approaches |
title_fullStr |
Intaglio Surface Adaptation of Removable Partial Denture Framework Fabricated by Various Data Acquisition Techniques and Fabrication Approaches |
title_full_unstemmed |
Intaglio Surface Adaptation of Removable Partial Denture Framework Fabricated by Various Data Acquisition Techniques and Fabrication Approaches |
title_sort |
intaglio surface adaptation of removable partial denture framework fabricated by various data acquisition techniques and fabrication approaches |
publishDate |
2023 |
url |
https://repository.li.mahidol.ac.th/handle/123456789/90566 |
_version_ |
1781797433969213440 |