Degree of conversion of resin composite cured by light through a translucent fiber posts.

PURPOSE: This study evaluated the depth of cure of resin composite cured by light through a translucent fiber post. MATERIALS AND METHODS: The opaque plastic tubes in various lengths of 2, 4, 6, 8, 10, 12, 14 mm. were filled with resin composite in which two different translucent fiber posts were...

Full description

Saved in:
Bibliographic Details
Main Authors: Somchai Urapepon, สมชาย อุรพีพล
Format: Article
Language:English
Published: 2015
Subjects:
Online Access:https://repository.li.mahidol.ac.th/handle/123456789/995
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Mahidol University
Language: English
id th-mahidol.995
record_format dspace
spelling th-mahidol.9952023-04-12T15:24:36Z Degree of conversion of resin composite cured by light through a translucent fiber posts. Somchai Urapepon สมชาย อุรพีพล Somchai Urapepon สมชาย อุรพีพล Mahidol University. Faculty of Dentistry. Department of Prosthodontics Degree of conversion Depth of cure Light transmission Resin composite Translucent post Open Access article PURPOSE: This study evaluated the depth of cure of resin composite cured by light through a translucent fiber post. MATERIALS AND METHODS: The opaque plastic tubes in various lengths of 2, 4, 6, 8, 10, 12, 14 mm. were filled with resin composite in which two different translucent fiber posts were inserted into the center and photo-polymerized for 40 seconds. The degree of conversion of the cured composite at bottom surface were examined using Fourier transform infrared attenuated total reflection spectrometer (FTIR/ATR) at 0.1, 0.5 and 1.0 mm apart from the post surface. RESULTS: The degree of conversion of the 0.1 mm, 0.5 mm, 1.0 mm apart from the post surface was highest at the 2 mm level and continuously decreased when the distance from the light source was increased and drastically decreased when the depth from the top of the post was greater than 4-6 mm. For each level, the highest degree of conversion was at 0.1 mm from the post surface and decreased continuously when the distance apart from the post surface was increased. CONCLUSION: The quantity of light transmission depends on the type of post and the light transmission capability of the post, especially after 4-6 mm depth and the area further apart from the post surface, are insufficient for clinical light activation of resin composite. 2015-09-29T09:31:18Z 2016-12-13T06:37:05Z 2015-09-29T09:31:18Z 2016-12-13T06:37:05Z 2015-09-22 2014-06 Article Urapepon S. Degree of conversion of resin composite cured by light through a translucent fiber posts. J Adv Prosthodont. 2014 Jun; 6(3): 194–9. 10.4047/jap.2014.6.3.194 2005-7806 (printed) 2005-7814 (electronic) https://repository.li.mahidol.ac.th/handle/123456789/995 eng Mahidol University PubMed Central application/pdf
institution Mahidol University
building Mahidol University Library
continent Asia
country Thailand
Thailand
content_provider Mahidol University Library
collection Mahidol University Institutional Repository
language English
topic Degree of conversion
Depth of cure
Light transmission
Resin composite
Translucent post
Open Access article
spellingShingle Degree of conversion
Depth of cure
Light transmission
Resin composite
Translucent post
Open Access article
Somchai Urapepon
สมชาย อุรพีพล
Degree of conversion of resin composite cured by light through a translucent fiber posts.
description PURPOSE: This study evaluated the depth of cure of resin composite cured by light through a translucent fiber post. MATERIALS AND METHODS: The opaque plastic tubes in various lengths of 2, 4, 6, 8, 10, 12, 14 mm. were filled with resin composite in which two different translucent fiber posts were inserted into the center and photo-polymerized for 40 seconds. The degree of conversion of the cured composite at bottom surface were examined using Fourier transform infrared attenuated total reflection spectrometer (FTIR/ATR) at 0.1, 0.5 and 1.0 mm apart from the post surface. RESULTS: The degree of conversion of the 0.1 mm, 0.5 mm, 1.0 mm apart from the post surface was highest at the 2 mm level and continuously decreased when the distance from the light source was increased and drastically decreased when the depth from the top of the post was greater than 4-6 mm. For each level, the highest degree of conversion was at 0.1 mm from the post surface and decreased continuously when the distance apart from the post surface was increased. CONCLUSION: The quantity of light transmission depends on the type of post and the light transmission capability of the post, especially after 4-6 mm depth and the area further apart from the post surface, are insufficient for clinical light activation of resin composite.
author2 Somchai Urapepon
author_facet Somchai Urapepon
Somchai Urapepon
สมชาย อุรพีพล
format Article
author Somchai Urapepon
สมชาย อุรพีพล
author_sort Somchai Urapepon
title Degree of conversion of resin composite cured by light through a translucent fiber posts.
title_short Degree of conversion of resin composite cured by light through a translucent fiber posts.
title_full Degree of conversion of resin composite cured by light through a translucent fiber posts.
title_fullStr Degree of conversion of resin composite cured by light through a translucent fiber posts.
title_full_unstemmed Degree of conversion of resin composite cured by light through a translucent fiber posts.
title_sort degree of conversion of resin composite cured by light through a translucent fiber posts.
publishDate 2015
url https://repository.li.mahidol.ac.th/handle/123456789/995
_version_ 1781414599025754112