Soft x-rays from plasma focus / Chaivity Silawatshananai

The temporal characteristics of the X-ray emission in a small 3 kJ plasma focus of Mather type are investigated when operating in deuterium, argon and nitrogen gases. The soft X-ray emission is detected with a five channels BPX-65 PIN-diode spectrometer, looking axially into the focussing region. Re...

Full description

Saved in:
Bibliographic Details
Main Author: Chaivitya Silawatshananai
Other Authors: Faculty of Sciecnce and Technology (Science)
Format: Technical Report
Language:English
Published: Prince of Songkla University 2024
Subjects:
Online Access:http://kb.psu.ac.th/psukb/handle/2016/19359
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Prince of Songkhla University
Language: English
id th-psu.2016-19359
record_format dspace
spelling th-psu.2016-193592024-02-14T08:44:50Z Soft x-rays from plasma focus / Chaivity Silawatshananai Chaivitya Silawatshananai Faculty of Sciecnce and Technology (Science) คณะวิทยาศาสตร์และเทคโนโลยี ภาควิชาวิทยาศาสตร์ Grenz rays X-rays The temporal characteristics of the X-ray emission in a small 3 kJ plasma focus of Mather type are investigated when operating in deuterium, argon and nitrogen gases. The soft X-ray emission is detected with a five channels BPX-65 PIN-diode spectrometer, looking axially into the focussing region. Results show that soft X-ray emission coincides with successive plasma compressions. Some spectra contain the copper K line radiation. This strong copper line radiation is due to electron beam-anode interaction or focussing effect of copper vapour contaminated plasma. Electron temperatures in argon and deuterium plasmas are inferred from the ratio of x-ray intensities to be 1.5 KeV and ~10 KeV respectively. Prince of Songkla University ได้ศึกษาสมบัติของรังสีเอกซ์เชิงเวลาที่เปล่งจากพลาสมาโฟกัสขนาด 3 กิโลจูล แบบแมท เธอร์ เมื่อใช้ก๊าซผิวที่เรียม อาร์กอน และไนโตรเจน รังสีเอกซ์อย่างอ่อนถูกตรวจวัดทางด้านข้าง โดยใช้สเปกโตรมิเตอร์แบบ BPX-65 ไดโอดห้าช่อง ผลการทดลองพบว่า การเปล่งรังสีเอกซ์อย่างอ่อนเกิดขึ้นพร้อมกับการอัดตัวของพลาสมา ปรากฎพบเส้นรังสีทองแดง K ในสเปกตราบางแถบของทองแดงนี้เกิดจากปฏิกิริยาของอิเล็กตรอนกับขั้วแอโนดเส้นรังสีเข้มหรือจากการโฟคัสของพลาสมาที่เจือด้วยไอทองแดง จากอัตราส่วนของความเข้มรังสีเอกซ์ พบว่า อุณหภูมิอิเล็กตรอนในพลาสมาก๊าซอาร์กอนและ ตัวที่เรียม มีค่า 1.5 Key และ 10 Key 2024-02-14T08:44:50Z 2024-02-14T08:44:50Z 1992 Technical Report http://kb.psu.ac.th/psukb/handle/2016/19359 en application/pdf Prince of Songkla University
institution Prince of Songkhla University
building Khunying Long Athakravi Sunthorn Learning Resources Center
continent Asia
country Thailand
Thailand
content_provider Khunying Long Athakravi Sunthorn Learning Resources Center
collection PSU Knowledge Bank
language English
topic Grenz rays
X-rays
spellingShingle Grenz rays
X-rays
Chaivitya Silawatshananai
Soft x-rays from plasma focus / Chaivity Silawatshananai
description The temporal characteristics of the X-ray emission in a small 3 kJ plasma focus of Mather type are investigated when operating in deuterium, argon and nitrogen gases. The soft X-ray emission is detected with a five channels BPX-65 PIN-diode spectrometer, looking axially into the focussing region. Results show that soft X-ray emission coincides with successive plasma compressions. Some spectra contain the copper K line radiation. This strong copper line radiation is due to electron beam-anode interaction or focussing effect of copper vapour contaminated plasma. Electron temperatures in argon and deuterium plasmas are inferred from the ratio of x-ray intensities to be 1.5 KeV and ~10 KeV respectively.
author2 Faculty of Sciecnce and Technology (Science)
author_facet Faculty of Sciecnce and Technology (Science)
Chaivitya Silawatshananai
format Technical Report
author Chaivitya Silawatshananai
author_sort Chaivitya Silawatshananai
title Soft x-rays from plasma focus / Chaivity Silawatshananai
title_short Soft x-rays from plasma focus / Chaivity Silawatshananai
title_full Soft x-rays from plasma focus / Chaivity Silawatshananai
title_fullStr Soft x-rays from plasma focus / Chaivity Silawatshananai
title_full_unstemmed Soft x-rays from plasma focus / Chaivity Silawatshananai
title_sort soft x-rays from plasma focus / chaivity silawatshananai
publisher Prince of Songkla University
publishDate 2024
url http://kb.psu.ac.th/psukb/handle/2016/19359
_version_ 1792200105497985024