Preconcentration and Analysis of Metal Ion Cu(II) Based on Flow Injection Analysis

Water pollution by copper has been a common case. Monitoring the water pollution requires analysis method which is simple, sensitive, and has good detection limitation. Since the metal ion Cu(II) in the environment generally in trace level. One of ways to solve this problem is by using pre-concent...

Full description

Saved in:
Bibliographic Details
Main Author: TRIJAYANTI (NIM 10505094), ASTUTI
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/11889
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:11889
spelling id-itb.:118892017-09-27T11:42:37ZPreconcentration and Analysis of Metal Ion Cu(II) Based on Flow Injection Analysis TRIJAYANTI (NIM 10505094), ASTUTI Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/11889 Water pollution by copper has been a common case. Monitoring the water pollution requires analysis method which is simple, sensitive, and has good detection limitation. Since the metal ion Cu(II) in the environment generally in trace level. One of ways to solve this problem is by using pre-concentration based on FIA technique. In this research, an analytical method using modified polistiren divinilbenzen resin with a-nitroso-B-naftol has been developed and evaluated. The modified resin has a retention capacity of 0.56 mg Cu(II)/g resin on pH 6.50 with minimum contact time of 11 minutes. The retention characteristics of resin has enabled to use it as mini column filling material for pre-concentration based on FIA. A 0.60 mL of 1 M nitric acid was capable to quantitatively elute of retained metal Cu(II). Analytical performance from the develop method is very well as shown by the detection limit of 1.68 ppb, with good linearity in concentration range 20–300 ppb. Application of developed method in water sample analysis results recovery by 97.24%. The result obtained shows that developed pre-concentration method can be used for trace analysis of copper in the environment. <br /> text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Water pollution by copper has been a common case. Monitoring the water pollution requires analysis method which is simple, sensitive, and has good detection limitation. Since the metal ion Cu(II) in the environment generally in trace level. One of ways to solve this problem is by using pre-concentration based on FIA technique. In this research, an analytical method using modified polistiren divinilbenzen resin with a-nitroso-B-naftol has been developed and evaluated. The modified resin has a retention capacity of 0.56 mg Cu(II)/g resin on pH 6.50 with minimum contact time of 11 minutes. The retention characteristics of resin has enabled to use it as mini column filling material for pre-concentration based on FIA. A 0.60 mL of 1 M nitric acid was capable to quantitatively elute of retained metal Cu(II). Analytical performance from the develop method is very well as shown by the detection limit of 1.68 ppb, with good linearity in concentration range 20–300 ppb. Application of developed method in water sample analysis results recovery by 97.24%. The result obtained shows that developed pre-concentration method can be used for trace analysis of copper in the environment. <br />
format Final Project
author TRIJAYANTI (NIM 10505094), ASTUTI
spellingShingle TRIJAYANTI (NIM 10505094), ASTUTI
Preconcentration and Analysis of Metal Ion Cu(II) Based on Flow Injection Analysis
author_facet TRIJAYANTI (NIM 10505094), ASTUTI
author_sort TRIJAYANTI (NIM 10505094), ASTUTI
title Preconcentration and Analysis of Metal Ion Cu(II) Based on Flow Injection Analysis
title_short Preconcentration and Analysis of Metal Ion Cu(II) Based on Flow Injection Analysis
title_full Preconcentration and Analysis of Metal Ion Cu(II) Based on Flow Injection Analysis
title_fullStr Preconcentration and Analysis of Metal Ion Cu(II) Based on Flow Injection Analysis
title_full_unstemmed Preconcentration and Analysis of Metal Ion Cu(II) Based on Flow Injection Analysis
title_sort preconcentration and analysis of metal ion cu(ii) based on flow injection analysis
url https://digilib.itb.ac.id/gdl/view/11889
_version_ 1820728346947878912