Preconcentration and Selective Trace Analysis of Ion Cd(II) Use Chelating Resin
The preconcentration step is a step that cannot be ignored from trace analysis method. Cadmium present in environment at trace level concentration with very complex matrix. An analytical methods which included a preconcentration step is needed to solve this problem. In this research, preconcentrati...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/12487 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:12487 |
---|---|
spelling |
id-itb.:124872017-09-27T11:42:36ZPreconcentration and Selective Trace Analysis of Ion Cd(II) Use Chelating Resin MUBAROKAH (NIM 10505006), NUR Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/12487 The preconcentration step is a step that cannot be ignored from trace analysis method. Cadmium present in environment at trace level concentration with very complex matrix. An analytical methods which included a preconcentration step is needed to solve this problem. In this research, preconcentration technique based on Flow Injection Analysis (FIA) with chelating resin polystyrene divinilbenzene1-(2-Pyridylazo)-2-naphtol (PSDVB-PAN) was developed and evaluated. This chelating resin was synthesized and characterized that had retention to metal ion Cd(II). It is found that the resin's capacity of retention is 0.58 mg Cd(II)/g resin at optimum pH 6.5 by minimum contact time 15 minutes. The used of resin as a preconcentration column material in FIA technique showed good analytical performance. Precision value reached 1.79% KV for concentration 50 ppb. This method also shows a linearity at concentration rate 10-125 ppb (R2=0.993) with sensitivity 0.6 ppb and detection limit 1.5 ppb. Based on this research, the test of Citarum's water is giving result ion Cd(II) concentration 22 ppb with recovery percent 97.74%. <br /> text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
description |
The preconcentration step is a step that cannot be ignored from trace analysis method. Cadmium present in environment at trace level concentration with very complex matrix. An analytical methods which included a preconcentration step is needed to solve this problem. In this research, preconcentration technique based on Flow Injection Analysis (FIA) with chelating resin polystyrene divinilbenzene1-(2-Pyridylazo)-2-naphtol (PSDVB-PAN) was developed and evaluated. This chelating resin was synthesized and characterized that had retention to metal ion Cd(II). It is found that the resin's capacity of retention is 0.58 mg Cd(II)/g resin at optimum pH 6.5 by minimum contact time 15 minutes. The used of resin as a preconcentration column material in FIA technique showed good analytical performance. Precision value reached 1.79% KV for concentration 50 ppb. This method also shows a linearity at concentration rate 10-125 ppb (R2=0.993) with sensitivity 0.6 ppb and detection limit 1.5 ppb. Based on this research, the test of Citarum's water is giving result ion Cd(II) concentration 22 ppb with recovery percent 97.74%. <br />
|
format |
Final Project |
author |
MUBAROKAH (NIM 10505006), NUR |
spellingShingle |
MUBAROKAH (NIM 10505006), NUR Preconcentration and Selective Trace Analysis of Ion Cd(II) Use Chelating Resin |
author_facet |
MUBAROKAH (NIM 10505006), NUR |
author_sort |
MUBAROKAH (NIM 10505006), NUR |
title |
Preconcentration and Selective Trace Analysis of Ion Cd(II) Use Chelating Resin |
title_short |
Preconcentration and Selective Trace Analysis of Ion Cd(II) Use Chelating Resin |
title_full |
Preconcentration and Selective Trace Analysis of Ion Cd(II) Use Chelating Resin |
title_fullStr |
Preconcentration and Selective Trace Analysis of Ion Cd(II) Use Chelating Resin |
title_full_unstemmed |
Preconcentration and Selective Trace Analysis of Ion Cd(II) Use Chelating Resin |
title_sort |
preconcentration and selective trace analysis of ion cd(ii) use chelating resin |
url |
https://digilib.itb.ac.id/gdl/view/12487 |
_version_ |
1820728535545806848 |