RISK ASSESSMENT FOR PRODUCTION SEPARATOR IN SEPARATION SYSTEM BASED ON DNV RP-G101 CASE STUDY: LIMA FLOW STATION

Risk Assessment is an activity to calculate the value of the risk from a system and equipment. The purpose of risk assessment is to reduce and minimize the negative impacts <br /> <br /> <br /> that threaten the safety aspects, financial losses, nor environmental damage suffered...

Full description

Saved in:
Bibliographic Details
Main Author: MANURUNG (NIM : 13106023); Dosen Pembimbing : Prof. Dr. Ir. IGN Wiratmaja Puja, IMMANUEL
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/16035
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:16035
spelling id-itb.:160352017-09-27T10:40:53ZRISK ASSESSMENT FOR PRODUCTION SEPARATOR IN SEPARATION SYSTEM BASED ON DNV RP-G101 CASE STUDY: LIMA FLOW STATION MANURUNG (NIM : 13106023); Dosen Pembimbing : Prof. Dr. Ir. IGN Wiratmaja Puja, IMMANUEL Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/16035 Risk Assessment is an activity to calculate the value of the risk from a system and equipment. The purpose of risk assessment is to reduce and minimize the negative impacts <br /> <br /> <br /> that threaten the safety aspects, financial losses, nor environmental damage suffered by the company. <br /> <br /> <br /> This final project is to analyze the level and value of risk from a system (screening) and equipment (detailed assessment) using DNV RP-G101 that reviewing the Risk <br /> <br /> <br /> Assessment of Offshore Topside Static Mechanical Equipment. A case study performed on production separator of the platform LPRO separation system, Lima Flow Station. <br /> <br /> <br /> From the screening’s level, there’s systems that has a high level of risk and should be further analyzed at the level of detailed assessment on the system. It is include Wellhead, sand separator, separation, gas processing, gas compression, crude oil handling, drain system, fuel system, and flare system. By analyzing separation system in this final project there are three equipment with high risk value, including LPV-3 Top (Production Separator) with safety consequence value 3.925 (Category E), economic consequence value US$ 38693, and PoF 0.00118 (category 4 ); LPV-5 Top (LP Flare KO Drum) with a safety consequence value 1.8538 (Category E), economic consequence value US$ 38499, and PoF 0.00361 (category 4); LPV-7 Top (Fuel Gas Scrubber) with safety consequence value 2.13 (Category E), economic consequence value of US$ 166970, and PoF 0.00374 (category 4). With those high risk equipment level, there is so important to plan some further handling to reduce probability and consequence of failure, such as mitigation activity, repair the equipments, or replace the equipments for LPV-3, LPV-5, and LPV-7. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Risk Assessment is an activity to calculate the value of the risk from a system and equipment. The purpose of risk assessment is to reduce and minimize the negative impacts <br /> <br /> <br /> that threaten the safety aspects, financial losses, nor environmental damage suffered by the company. <br /> <br /> <br /> This final project is to analyze the level and value of risk from a system (screening) and equipment (detailed assessment) using DNV RP-G101 that reviewing the Risk <br /> <br /> <br /> Assessment of Offshore Topside Static Mechanical Equipment. A case study performed on production separator of the platform LPRO separation system, Lima Flow Station. <br /> <br /> <br /> From the screening’s level, there’s systems that has a high level of risk and should be further analyzed at the level of detailed assessment on the system. It is include Wellhead, sand separator, separation, gas processing, gas compression, crude oil handling, drain system, fuel system, and flare system. By analyzing separation system in this final project there are three equipment with high risk value, including LPV-3 Top (Production Separator) with safety consequence value 3.925 (Category E), economic consequence value US$ 38693, and PoF 0.00118 (category 4 ); LPV-5 Top (LP Flare KO Drum) with a safety consequence value 1.8538 (Category E), economic consequence value US$ 38499, and PoF 0.00361 (category 4); LPV-7 Top (Fuel Gas Scrubber) with safety consequence value 2.13 (Category E), economic consequence value of US$ 166970, and PoF 0.00374 (category 4). With those high risk equipment level, there is so important to plan some further handling to reduce probability and consequence of failure, such as mitigation activity, repair the equipments, or replace the equipments for LPV-3, LPV-5, and LPV-7.
format Final Project
author MANURUNG (NIM : 13106023); Dosen Pembimbing : Prof. Dr. Ir. IGN Wiratmaja Puja, IMMANUEL
spellingShingle MANURUNG (NIM : 13106023); Dosen Pembimbing : Prof. Dr. Ir. IGN Wiratmaja Puja, IMMANUEL
RISK ASSESSMENT FOR PRODUCTION SEPARATOR IN SEPARATION SYSTEM BASED ON DNV RP-G101 CASE STUDY: LIMA FLOW STATION
author_facet MANURUNG (NIM : 13106023); Dosen Pembimbing : Prof. Dr. Ir. IGN Wiratmaja Puja, IMMANUEL
author_sort MANURUNG (NIM : 13106023); Dosen Pembimbing : Prof. Dr. Ir. IGN Wiratmaja Puja, IMMANUEL
title RISK ASSESSMENT FOR PRODUCTION SEPARATOR IN SEPARATION SYSTEM BASED ON DNV RP-G101 CASE STUDY: LIMA FLOW STATION
title_short RISK ASSESSMENT FOR PRODUCTION SEPARATOR IN SEPARATION SYSTEM BASED ON DNV RP-G101 CASE STUDY: LIMA FLOW STATION
title_full RISK ASSESSMENT FOR PRODUCTION SEPARATOR IN SEPARATION SYSTEM BASED ON DNV RP-G101 CASE STUDY: LIMA FLOW STATION
title_fullStr RISK ASSESSMENT FOR PRODUCTION SEPARATOR IN SEPARATION SYSTEM BASED ON DNV RP-G101 CASE STUDY: LIMA FLOW STATION
title_full_unstemmed RISK ASSESSMENT FOR PRODUCTION SEPARATOR IN SEPARATION SYSTEM BASED ON DNV RP-G101 CASE STUDY: LIMA FLOW STATION
title_sort risk assessment for production separator in separation system based on dnv rp-g101 case study: lima flow station
url https://digilib.itb.ac.id/gdl/view/16035
_version_ 1820737606649905152