#TITLE_ALTERNATIVE#

Every orthodontic must have all knowledge about orthodontic wire’s characteristic that used in orthodontia practice. Nowadays, orthodontics decisions to choose dimension, geometry and model based only from literature, experience <br /> <br /> <br /> and intuition he has. To en...

Full description

Saved in:
Bibliographic Details
Main Author: PANCA YUDHA (NIM : 13104063); Pembimbing 1 : Dr. Ir. Rachman Setiawan; Pembimbing 2 : Dr., LANANG
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/16265
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:16265
spelling id-itb.:162652017-09-27T10:40:50Z#TITLE_ALTERNATIVE# PANCA YUDHA (NIM : 13104063); Pembimbing 1 : Dr. Ir. Rachman Setiawan; Pembimbing 2 : Dr., LANANG Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/16265 Every orthodontic must have all knowledge about orthodontic wire’s characteristic that used in orthodontia practice. Nowadays, orthodontics decisions to choose dimension, geometry and model based only from literature, experience <br /> <br /> <br /> and intuition he has. To ensure the characteristic of orthodontic wire as a clinical reference, a measurement device that can be used to measures for force and moment in orthodontic wire is urgently required. And by an accurate <br /> <br /> <br /> characteristic of orthodontic wire, orthodontic treatment will become more precise and effective. <br /> <br /> <br /> The last final project has successfully made measurement device that can be used to measures the effect of activation distance on the intensity of force and moment. Device’s testing results show that this measurement device can be used to measure force and moment produced by the spring. Result of force measurement is satisfying, but the result of moment measurement shows wide data variation that is estimated comes from error while testing the device. Based on the evaluation, this measurement device has adequate resolution and uncertainty comparable to the requirement of resolution and uncertainty to measure force and moment in orthodontic. However, some modification must be done to reduce sources of error while measuring, i.e. redesign and remanufacturing sensor, repairing calibration method for moment measurement, strengthening bracket adhesion, using auxiliary device to check perpendicularity <br /> <br /> <br /> of spring, do more accurate pre-activation distance measurement between bracket, repair sliding mechanism and developing activation indicator. This final project focus on describes about process of redesigning, manufacturing and testing of portable measurement device that can be used to measures the effect of activation distance on the intensity of force and moment produced by orthodontic wire. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Every orthodontic must have all knowledge about orthodontic wire’s characteristic that used in orthodontia practice. Nowadays, orthodontics decisions to choose dimension, geometry and model based only from literature, experience <br /> <br /> <br /> and intuition he has. To ensure the characteristic of orthodontic wire as a clinical reference, a measurement device that can be used to measures for force and moment in orthodontic wire is urgently required. And by an accurate <br /> <br /> <br /> characteristic of orthodontic wire, orthodontic treatment will become more precise and effective. <br /> <br /> <br /> The last final project has successfully made measurement device that can be used to measures the effect of activation distance on the intensity of force and moment. Device’s testing results show that this measurement device can be used to measure force and moment produced by the spring. Result of force measurement is satisfying, but the result of moment measurement shows wide data variation that is estimated comes from error while testing the device. Based on the evaluation, this measurement device has adequate resolution and uncertainty comparable to the requirement of resolution and uncertainty to measure force and moment in orthodontic. However, some modification must be done to reduce sources of error while measuring, i.e. redesign and remanufacturing sensor, repairing calibration method for moment measurement, strengthening bracket adhesion, using auxiliary device to check perpendicularity <br /> <br /> <br /> of spring, do more accurate pre-activation distance measurement between bracket, repair sliding mechanism and developing activation indicator. This final project focus on describes about process of redesigning, manufacturing and testing of portable measurement device that can be used to measures the effect of activation distance on the intensity of force and moment produced by orthodontic wire.
format Final Project
author PANCA YUDHA (NIM : 13104063); Pembimbing 1 : Dr. Ir. Rachman Setiawan; Pembimbing 2 : Dr., LANANG
spellingShingle PANCA YUDHA (NIM : 13104063); Pembimbing 1 : Dr. Ir. Rachman Setiawan; Pembimbing 2 : Dr., LANANG
#TITLE_ALTERNATIVE#
author_facet PANCA YUDHA (NIM : 13104063); Pembimbing 1 : Dr. Ir. Rachman Setiawan; Pembimbing 2 : Dr., LANANG
author_sort PANCA YUDHA (NIM : 13104063); Pembimbing 1 : Dr. Ir. Rachman Setiawan; Pembimbing 2 : Dr., LANANG
title #TITLE_ALTERNATIVE#
title_short #TITLE_ALTERNATIVE#
title_full #TITLE_ALTERNATIVE#
title_fullStr #TITLE_ALTERNATIVE#
title_full_unstemmed #TITLE_ALTERNATIVE#
title_sort #title_alternative#
url https://digilib.itb.ac.id/gdl/view/16265
_version_ 1820745332438335488