DIMENSIONING OF A 3-MW N-PENTANE TWO-STAGE RATEAU TURBINE NOZZLE AND BLADE IN A GEOTHERMAL BINARY CYCLE
The geographical position of Indonesia is located on the mountain path keep the active geothermal potential of 28 GW, about 30-40% of the world. Government plans to develop up to 9500 MW at 2025. <br /> <br /> <br /> PLTP examined is PLTP Lahendong, North Sulawesi. This PLTP uses...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/17181 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:17181 |
---|---|
spelling |
id-itb.:171812017-09-27T10:40:54ZDIMENSIONING OF A 3-MW N-PENTANE TWO-STAGE RATEAU TURBINE NOZZLE AND BLADE IN A GEOTHERMAL BINARY CYCLE DWI PRAKOSO (NIM : 13106039); Pembimbing 1 : Dr.Ir. Sigit Yoewono ; Pembimbing 2 : Ir. Hendi , SATRIO Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/17181 The geographical position of Indonesia is located on the mountain path keep the active geothermal potential of 28 GW, about 30-40% of the world. Government plans to develop up to 9500 MW at 2025. <br /> <br /> <br /> PLTP examined is PLTP Lahendong, North Sulawesi. This PLTP uses the binary system PLTP with fluid n-pentane. The binary system is used because the wells have a low temperature, i.e. 138oC. From existing cycle taken the pressure, temperature, rotational speed and power. Then, from those parameters were chosen a suitable type of turbine based on specific speeds, literature reviews, and manufacturing processes. Turbine type chosen is the impulse turbines with two levels of pressure. <br /> <br /> <br /> The calculation is performed to find the best internal efficiency turbines each level by assuming the price u/c1 then those parameters used to determine the dimensions of nozzles and blades which will be drawn using Autodesk Inventor. Internal efficiency obtained from the calculation will be compared with the assumption of efficiency from the initial design. Internal efficiency of the internal which is designed for 0.82 and 0.66 obtained at the end of the calculation. text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
description |
The geographical position of Indonesia is located on the mountain path keep the active geothermal potential of 28 GW, about 30-40% of the world. Government plans to develop up to 9500 MW at 2025. <br />
<br />
<br />
PLTP examined is PLTP Lahendong, North Sulawesi. This PLTP uses the binary system PLTP with fluid n-pentane. The binary system is used because the wells have a low temperature, i.e. 138oC. From existing cycle taken the pressure, temperature, rotational speed and power. Then, from those parameters were chosen a suitable type of turbine based on specific speeds, literature reviews, and manufacturing processes. Turbine type chosen is the impulse turbines with two levels of pressure. <br />
<br />
<br />
The calculation is performed to find the best internal efficiency turbines each level by assuming the price u/c1 then those parameters used to determine the dimensions of nozzles and blades which will be drawn using Autodesk Inventor. Internal efficiency obtained from the calculation will be compared with the assumption of efficiency from the initial design. Internal efficiency of the internal which is designed for 0.82 and 0.66 obtained at the end of the calculation. |
format |
Final Project |
author |
DWI PRAKOSO (NIM : 13106039); Pembimbing 1 : Dr.Ir. Sigit Yoewono ; Pembimbing 2 : Ir. Hendi , SATRIO |
spellingShingle |
DWI PRAKOSO (NIM : 13106039); Pembimbing 1 : Dr.Ir. Sigit Yoewono ; Pembimbing 2 : Ir. Hendi , SATRIO DIMENSIONING OF A 3-MW N-PENTANE TWO-STAGE RATEAU TURBINE NOZZLE AND BLADE IN A GEOTHERMAL BINARY CYCLE |
author_facet |
DWI PRAKOSO (NIM : 13106039); Pembimbing 1 : Dr.Ir. Sigit Yoewono ; Pembimbing 2 : Ir. Hendi , SATRIO |
author_sort |
DWI PRAKOSO (NIM : 13106039); Pembimbing 1 : Dr.Ir. Sigit Yoewono ; Pembimbing 2 : Ir. Hendi , SATRIO |
title |
DIMENSIONING OF A 3-MW N-PENTANE TWO-STAGE RATEAU TURBINE NOZZLE AND BLADE IN A GEOTHERMAL BINARY CYCLE |
title_short |
DIMENSIONING OF A 3-MW N-PENTANE TWO-STAGE RATEAU TURBINE NOZZLE AND BLADE IN A GEOTHERMAL BINARY CYCLE |
title_full |
DIMENSIONING OF A 3-MW N-PENTANE TWO-STAGE RATEAU TURBINE NOZZLE AND BLADE IN A GEOTHERMAL BINARY CYCLE |
title_fullStr |
DIMENSIONING OF A 3-MW N-PENTANE TWO-STAGE RATEAU TURBINE NOZZLE AND BLADE IN A GEOTHERMAL BINARY CYCLE |
title_full_unstemmed |
DIMENSIONING OF A 3-MW N-PENTANE TWO-STAGE RATEAU TURBINE NOZZLE AND BLADE IN A GEOTHERMAL BINARY CYCLE |
title_sort |
dimensioning of a 3-mw n-pentane two-stage rateau turbine nozzle and blade in a geothermal binary cycle |
url |
https://digilib.itb.ac.id/gdl/view/17181 |
_version_ |
1820745550317748224 |