DIMENSIONING OF A 3-MW N-PENTANE TWO-STAGE RATEAU TURBINE NOZZLE AND BLADE IN A GEOTHERMAL BINARY CYCLE

The geographical position of Indonesia is located on the mountain path keep the active geothermal potential of 28 GW, about 30-40% of the world. Government plans to develop up to 9500 MW at 2025. <br /> <br /> <br /> PLTP examined is PLTP Lahendong, North Sulawesi. This PLTP uses...

Full description

Saved in:
Bibliographic Details
Main Author: DWI PRAKOSO (NIM : 13106039); Pembimbing 1 : Dr.Ir. Sigit Yoewono ; Pembimbing 2 : Ir. Hendi , SATRIO
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/17181
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:17181
spelling id-itb.:171812017-09-27T10:40:54ZDIMENSIONING OF A 3-MW N-PENTANE TWO-STAGE RATEAU TURBINE NOZZLE AND BLADE IN A GEOTHERMAL BINARY CYCLE DWI PRAKOSO (NIM : 13106039); Pembimbing 1 : Dr.Ir. Sigit Yoewono ; Pembimbing 2 : Ir. Hendi , SATRIO Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/17181 The geographical position of Indonesia is located on the mountain path keep the active geothermal potential of 28 GW, about 30-40% of the world. Government plans to develop up to 9500 MW at 2025. <br /> <br /> <br /> PLTP examined is PLTP Lahendong, North Sulawesi. This PLTP uses the binary system PLTP with fluid n-pentane. The binary system is used because the wells have a low temperature, i.e. 138oC. From existing cycle taken the pressure, temperature, rotational speed and power. Then, from those parameters were chosen a suitable type of turbine based on specific speeds, literature reviews, and manufacturing processes. Turbine type chosen is the impulse turbines with two levels of pressure. <br /> <br /> <br /> The calculation is performed to find the best internal efficiency turbines each level by assuming the price u/c1 then those parameters used to determine the dimensions of nozzles and blades which will be drawn using Autodesk Inventor. Internal efficiency obtained from the calculation will be compared with the assumption of efficiency from the initial design. Internal efficiency of the internal which is designed for 0.82 and 0.66 obtained at the end of the calculation. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description The geographical position of Indonesia is located on the mountain path keep the active geothermal potential of 28 GW, about 30-40% of the world. Government plans to develop up to 9500 MW at 2025. <br /> <br /> <br /> PLTP examined is PLTP Lahendong, North Sulawesi. This PLTP uses the binary system PLTP with fluid n-pentane. The binary system is used because the wells have a low temperature, i.e. 138oC. From existing cycle taken the pressure, temperature, rotational speed and power. Then, from those parameters were chosen a suitable type of turbine based on specific speeds, literature reviews, and manufacturing processes. Turbine type chosen is the impulse turbines with two levels of pressure. <br /> <br /> <br /> The calculation is performed to find the best internal efficiency turbines each level by assuming the price u/c1 then those parameters used to determine the dimensions of nozzles and blades which will be drawn using Autodesk Inventor. Internal efficiency obtained from the calculation will be compared with the assumption of efficiency from the initial design. Internal efficiency of the internal which is designed for 0.82 and 0.66 obtained at the end of the calculation.
format Final Project
author DWI PRAKOSO (NIM : 13106039); Pembimbing 1 : Dr.Ir. Sigit Yoewono ; Pembimbing 2 : Ir. Hendi , SATRIO
spellingShingle DWI PRAKOSO (NIM : 13106039); Pembimbing 1 : Dr.Ir. Sigit Yoewono ; Pembimbing 2 : Ir. Hendi , SATRIO
DIMENSIONING OF A 3-MW N-PENTANE TWO-STAGE RATEAU TURBINE NOZZLE AND BLADE IN A GEOTHERMAL BINARY CYCLE
author_facet DWI PRAKOSO (NIM : 13106039); Pembimbing 1 : Dr.Ir. Sigit Yoewono ; Pembimbing 2 : Ir. Hendi , SATRIO
author_sort DWI PRAKOSO (NIM : 13106039); Pembimbing 1 : Dr.Ir. Sigit Yoewono ; Pembimbing 2 : Ir. Hendi , SATRIO
title DIMENSIONING OF A 3-MW N-PENTANE TWO-STAGE RATEAU TURBINE NOZZLE AND BLADE IN A GEOTHERMAL BINARY CYCLE
title_short DIMENSIONING OF A 3-MW N-PENTANE TWO-STAGE RATEAU TURBINE NOZZLE AND BLADE IN A GEOTHERMAL BINARY CYCLE
title_full DIMENSIONING OF A 3-MW N-PENTANE TWO-STAGE RATEAU TURBINE NOZZLE AND BLADE IN A GEOTHERMAL BINARY CYCLE
title_fullStr DIMENSIONING OF A 3-MW N-PENTANE TWO-STAGE RATEAU TURBINE NOZZLE AND BLADE IN A GEOTHERMAL BINARY CYCLE
title_full_unstemmed DIMENSIONING OF A 3-MW N-PENTANE TWO-STAGE RATEAU TURBINE NOZZLE AND BLADE IN A GEOTHERMAL BINARY CYCLE
title_sort dimensioning of a 3-mw n-pentane two-stage rateau turbine nozzle and blade in a geothermal binary cycle
url https://digilib.itb.ac.id/gdl/view/17181
_version_ 1820745550317748224