PEMODELAN DEAERATOR PEMBANGKIT LISTRIK TENAGA GAS DAN UAP (PLTGU) GRESIK SERTA PENGONTROLANNYA DENGAN METODA KUADRATIK GAUSSIAN LINIER

Deaerator is the one of equipments in the installation of The Electrical Power Plant. This equipment is designed to remove the oxygen dissolved in the boiler feed water and as a water storage for the need boiler feed water. Deaerating process is performed by use in part of steam before entering stea...

Full description

Saved in:
Bibliographic Details
Main Author: Jati Prasetyo, Akhmadi
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/2006
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:2006
spelling id-itb.:20062004-11-11T14:40:58ZPEMODELAN DEAERATOR PEMBANGKIT LISTRIK TENAGA GAS DAN UAP (PLTGU) GRESIK SERTA PENGONTROLANNYA DENGAN METODA KUADRATIK GAUSSIAN LINIER Jati Prasetyo, Akhmadi Indonesia Theses INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/2006 Deaerator is the one of equipments in the installation of The Electrical Power Plant. This equipment is designed to remove the oxygen dissolved in the boiler feed water and as a water storage for the need boiler feed water. Deaerating process is performed by use in part of steam before entering steam turbine. This heating steam is used to increase temperature of the feed water flowing into the deaerator. Two control systems are used in the deaerator, as follows water level control and pressure control. In this research, have already made linear model of deaerator system in Gresik Combined Cycle Power Plant. The model is in the shape of state space with 4 inputs, 2 outputs and 5 state variables. Controller design is performed by use this model and apply LQG methode. By choosing design parameter such as state variable weighting matrix Q and control variable weighting matrix R and assuming system covariance matrix Qd and measurement covariance matrix Rd, hereafter has been obtained gain feeedback optimal Ke and gain Kalman Filter Ke. Simulation result shows that step response under normal condition make water level reach steady condition in 25 second and deaerator pressure reach steady condition in 20 second. Applying random disturbance in the input with 0.05 m3 / sec., filter damps disturbance as much 0.025 m (2.5 cm) for water level and 0.9 Kpa for deaerator pressure. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Deaerator is the one of equipments in the installation of The Electrical Power Plant. This equipment is designed to remove the oxygen dissolved in the boiler feed water and as a water storage for the need boiler feed water. Deaerating process is performed by use in part of steam before entering steam turbine. This heating steam is used to increase temperature of the feed water flowing into the deaerator. Two control systems are used in the deaerator, as follows water level control and pressure control. In this research, have already made linear model of deaerator system in Gresik Combined Cycle Power Plant. The model is in the shape of state space with 4 inputs, 2 outputs and 5 state variables. Controller design is performed by use this model and apply LQG methode. By choosing design parameter such as state variable weighting matrix Q and control variable weighting matrix R and assuming system covariance matrix Qd and measurement covariance matrix Rd, hereafter has been obtained gain feeedback optimal Ke and gain Kalman Filter Ke. Simulation result shows that step response under normal condition make water level reach steady condition in 25 second and deaerator pressure reach steady condition in 20 second. Applying random disturbance in the input with 0.05 m3 / sec., filter damps disturbance as much 0.025 m (2.5 cm) for water level and 0.9 Kpa for deaerator pressure.
format Theses
author Jati Prasetyo, Akhmadi
spellingShingle Jati Prasetyo, Akhmadi
PEMODELAN DEAERATOR PEMBANGKIT LISTRIK TENAGA GAS DAN UAP (PLTGU) GRESIK SERTA PENGONTROLANNYA DENGAN METODA KUADRATIK GAUSSIAN LINIER
author_facet Jati Prasetyo, Akhmadi
author_sort Jati Prasetyo, Akhmadi
title PEMODELAN DEAERATOR PEMBANGKIT LISTRIK TENAGA GAS DAN UAP (PLTGU) GRESIK SERTA PENGONTROLANNYA DENGAN METODA KUADRATIK GAUSSIAN LINIER
title_short PEMODELAN DEAERATOR PEMBANGKIT LISTRIK TENAGA GAS DAN UAP (PLTGU) GRESIK SERTA PENGONTROLANNYA DENGAN METODA KUADRATIK GAUSSIAN LINIER
title_full PEMODELAN DEAERATOR PEMBANGKIT LISTRIK TENAGA GAS DAN UAP (PLTGU) GRESIK SERTA PENGONTROLANNYA DENGAN METODA KUADRATIK GAUSSIAN LINIER
title_fullStr PEMODELAN DEAERATOR PEMBANGKIT LISTRIK TENAGA GAS DAN UAP (PLTGU) GRESIK SERTA PENGONTROLANNYA DENGAN METODA KUADRATIK GAUSSIAN LINIER
title_full_unstemmed PEMODELAN DEAERATOR PEMBANGKIT LISTRIK TENAGA GAS DAN UAP (PLTGU) GRESIK SERTA PENGONTROLANNYA DENGAN METODA KUADRATIK GAUSSIAN LINIER
title_sort pemodelan deaerator pembangkit listrik tenaga gas dan uap (pltgu) gresik serta pengontrolannya dengan metoda kuadratik gaussian linier
url https://digilib.itb.ac.id/gdl/view/2006
_version_ 1820663128095981568