APLIKASI ELEKTRODA SELEKTIF ION NITRAT TIPE KAWAT TERLAPIS UNTUK PENENTUAN SECARA TAK LANGSUNG GAS NO

Nitrate ion selective electrode based on coated wire with ion exchanger as ionophore has been constructed and characterized. The electrode has been used for the indirect determination of NO in air. The Nernstian response was found for nitrate concentration in the range of 104-10-1 M or 6,2 – 6200 p...

Full description

Saved in:
Bibliographic Details
Main Author: FARDIYAH, QONITAH
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/2201
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:2201
spelling id-itb.:22012004-10-19T09:50:36ZAPLIKASI ELEKTRODA SELEKTIF ION NITRAT TIPE KAWAT TERLAPIS UNTUK PENENTUAN SECARA TAK LANGSUNG GAS NO FARDIYAH, QONITAH Indonesia Theses INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/2201 Nitrate ion selective electrode based on coated wire with ion exchanger as ionophore has been constructed and characterized. The electrode has been used for the indirect determination of NO in air. The Nernstian response was found for nitrate concentration in the range of 104-10-1 M or 6,2 – 6200 ppm. Composition of the membrane is 7% aliquot-336 nitrat solution, 35% polyvynilchloride (PVC) and 58% of dioctylphtalate (DOP) in THE as solvent. In this condition, the sensivity of electrode was 57,7 mV/decade. Limit of detection for this ISE is 10-4 M or equivalent with 6, 2 ppm NO3-. The good reproducibility of the electrode was in 60 - 120 second of response time, life time was 27 days in pH condition 3 - 11, the thickness of membrane was 0,07 mm. Gases in atmosphere, espcecially NO, can absorbed stoichiometrically by the H2O2 solutions and converted to nitrate, and can be determinate indirect method with ISE. In the simulation of determination of NO gases, the optimum condition reach by flow rate of gases is 300 mL/minute, in acid condition by 0,0266 M H2SO4 with the excess of Nal concentration (75%) and the concentration of absorber solution twice of it's stoichiometric. Method of ISE can used to indirect determination of NO gases with range of concentration more than 6,2 ppm. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Nitrate ion selective electrode based on coated wire with ion exchanger as ionophore has been constructed and characterized. The electrode has been used for the indirect determination of NO in air. The Nernstian response was found for nitrate concentration in the range of 104-10-1 M or 6,2 – 6200 ppm. Composition of the membrane is 7% aliquot-336 nitrat solution, 35% polyvynilchloride (PVC) and 58% of dioctylphtalate (DOP) in THE as solvent. In this condition, the sensivity of electrode was 57,7 mV/decade. Limit of detection for this ISE is 10-4 M or equivalent with 6, 2 ppm NO3-. The good reproducibility of the electrode was in 60 - 120 second of response time, life time was 27 days in pH condition 3 - 11, the thickness of membrane was 0,07 mm. Gases in atmosphere, espcecially NO, can absorbed stoichiometrically by the H2O2 solutions and converted to nitrate, and can be determinate indirect method with ISE. In the simulation of determination of NO gases, the optimum condition reach by flow rate of gases is 300 mL/minute, in acid condition by 0,0266 M H2SO4 with the excess of Nal concentration (75%) and the concentration of absorber solution twice of it's stoichiometric. Method of ISE can used to indirect determination of NO gases with range of concentration more than 6,2 ppm.
format Theses
author FARDIYAH, QONITAH
spellingShingle FARDIYAH, QONITAH
APLIKASI ELEKTRODA SELEKTIF ION NITRAT TIPE KAWAT TERLAPIS UNTUK PENENTUAN SECARA TAK LANGSUNG GAS NO
author_facet FARDIYAH, QONITAH
author_sort FARDIYAH, QONITAH
title APLIKASI ELEKTRODA SELEKTIF ION NITRAT TIPE KAWAT TERLAPIS UNTUK PENENTUAN SECARA TAK LANGSUNG GAS NO
title_short APLIKASI ELEKTRODA SELEKTIF ION NITRAT TIPE KAWAT TERLAPIS UNTUK PENENTUAN SECARA TAK LANGSUNG GAS NO
title_full APLIKASI ELEKTRODA SELEKTIF ION NITRAT TIPE KAWAT TERLAPIS UNTUK PENENTUAN SECARA TAK LANGSUNG GAS NO
title_fullStr APLIKASI ELEKTRODA SELEKTIF ION NITRAT TIPE KAWAT TERLAPIS UNTUK PENENTUAN SECARA TAK LANGSUNG GAS NO
title_full_unstemmed APLIKASI ELEKTRODA SELEKTIF ION NITRAT TIPE KAWAT TERLAPIS UNTUK PENENTUAN SECARA TAK LANGSUNG GAS NO
title_sort aplikasi elektroda selektif ion nitrat tipe kawat terlapis untuk penentuan secara tak langsung gas no
url https://digilib.itb.ac.id/gdl/view/2201
_version_ 1820663186087477248