DESIGN OF DIAPHRAGM WALL AND BORED PILE FOUNDATION OFFICE BUILDING IN SERPONG

The Office Building in Gading Serpong is planned to be consist of a high tower with 3-4 floors of basement. With the 4 floors of basement, there must be a deep excavation work which will cause an unstability of soil around the area of excavation. Without any reinforcement system it will led to a lan...

Full description

Saved in:
Bibliographic Details
Main Author: HANUN, FATIMA
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/22101
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:22101
spelling id-itb.:221012017-12-05T14:59:37ZDESIGN OF DIAPHRAGM WALL AND BORED PILE FOUNDATION OFFICE BUILDING IN SERPONG HANUN, FATIMA Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/22101 The Office Building in Gading Serpong is planned to be consist of a high tower with 3-4 floors of basement. With the 4 floors of basement, there must be a deep excavation work which will cause an unstability of soil around the area of excavation. Without any reinforcement system it will led to a landslide. Other than that, a building with 16 floors will receive a great lateral load from earthquake and wind, so the foundation will need to be designed properly to meet the strength and service requirements from the codes. <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> In this final project, a diaphragm wall is designed to protect the excavation with a support of ground anchors, and is analyzed using PLAXIS 2D software. Besides, bored pile is also designed to accomodate the load of the building and is analyzed using Ensoft GROUP software. The design is based on Indonesian National Standard (SNI) for Geotechnical Engineering, SNI 2847:2013, SNI 1726:2012, and codes of TPKB DKI Jakarta. <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> The calculation result shows that the diaphragm wall needs to be constructed with the depth of 29 m and 0,6 m thickness. 3 anchors are needed to support the wall with 200 kN, 300 kN, and 350 kN prestress forces. The foundation is designed in 10 types with a various lenght ranges from 10-33 m and diameter of 0,6 m or 0,8 m depend on the amount of load works in every joint. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description The Office Building in Gading Serpong is planned to be consist of a high tower with 3-4 floors of basement. With the 4 floors of basement, there must be a deep excavation work which will cause an unstability of soil around the area of excavation. Without any reinforcement system it will led to a landslide. Other than that, a building with 16 floors will receive a great lateral load from earthquake and wind, so the foundation will need to be designed properly to meet the strength and service requirements from the codes. <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> In this final project, a diaphragm wall is designed to protect the excavation with a support of ground anchors, and is analyzed using PLAXIS 2D software. Besides, bored pile is also designed to accomodate the load of the building and is analyzed using Ensoft GROUP software. The design is based on Indonesian National Standard (SNI) for Geotechnical Engineering, SNI 2847:2013, SNI 1726:2012, and codes of TPKB DKI Jakarta. <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> <br /> The calculation result shows that the diaphragm wall needs to be constructed with the depth of 29 m and 0,6 m thickness. 3 anchors are needed to support the wall with 200 kN, 300 kN, and 350 kN prestress forces. The foundation is designed in 10 types with a various lenght ranges from 10-33 m and diameter of 0,6 m or 0,8 m depend on the amount of load works in every joint.
format Final Project
author HANUN, FATIMA
spellingShingle HANUN, FATIMA
DESIGN OF DIAPHRAGM WALL AND BORED PILE FOUNDATION OFFICE BUILDING IN SERPONG
author_facet HANUN, FATIMA
author_sort HANUN, FATIMA
title DESIGN OF DIAPHRAGM WALL AND BORED PILE FOUNDATION OFFICE BUILDING IN SERPONG
title_short DESIGN OF DIAPHRAGM WALL AND BORED PILE FOUNDATION OFFICE BUILDING IN SERPONG
title_full DESIGN OF DIAPHRAGM WALL AND BORED PILE FOUNDATION OFFICE BUILDING IN SERPONG
title_fullStr DESIGN OF DIAPHRAGM WALL AND BORED PILE FOUNDATION OFFICE BUILDING IN SERPONG
title_full_unstemmed DESIGN OF DIAPHRAGM WALL AND BORED PILE FOUNDATION OFFICE BUILDING IN SERPONG
title_sort design of diaphragm wall and bored pile foundation office building in serpong
url https://digilib.itb.ac.id/gdl/view/22101
_version_ 1821120667029864448