INDUCED VOLTAGE ON MEDIUM OVERHEAD LINE CAUSED BY NEARBY STRIKE FROM ROCKET TRIGGERED LIGHTNING

One of technical problem on the Hercules Feeder at PLN Karawang area is lightning disturbances. The high lightning density (5.5 stroke / km2 / year) in Jatiluhur Area caused lightning disturbanceand can be one of the factors caused trip of BBK and CLN recloser frequently. This lightning disturbance...

Full description

Saved in:
Bibliographic Details
Main Author: Eka Widodo, Krismanto
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/22844
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:22844
spelling id-itb.:228442017-09-27T15:37:42ZINDUCED VOLTAGE ON MEDIUM OVERHEAD LINE CAUSED BY NEARBY STRIKE FROM ROCKET TRIGGERED LIGHTNING Eka Widodo, Krismanto Indonesia Theses INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/22844 One of technical problem on the Hercules Feeder at PLN Karawang area is lightning disturbances. The high lightning density (5.5 stroke / km2 / year) in Jatiluhur Area caused lightning disturbanceand can be one of the factors caused trip of BBK and CLN recloser frequently. This lightning disturbance will cause more overvoltage on the distribution line, this disturbance can be either direct strike and indirect strike. In this research will be installed of new arrester with new innovation technology that is Multi Chamber Arrester (MCA) that used air gap and air pressure in the chamber as its technology. The MCA has a function to protect overhead lines from lightning, especially 20 kV medium voltage. The MCA protection system will be tested by rocket triggered lightning, the rocket platform is 81 meters from the Hercules Feeder in PLN Karawang Area. Calculation and analysis due to indirect strike will be done in this research by using Rusck method. The results of the calculation and analysis shows the performance of MCA capable to stop the peak current due to lightning induction current up to 16 kA and the comparison of MCA performance result has done at PLN Serpong Area and shows the MCA performance can reduce 36% line fault of Ruko Feeder after two years MCA installed. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description One of technical problem on the Hercules Feeder at PLN Karawang area is lightning disturbances. The high lightning density (5.5 stroke / km2 / year) in Jatiluhur Area caused lightning disturbanceand can be one of the factors caused trip of BBK and CLN recloser frequently. This lightning disturbance will cause more overvoltage on the distribution line, this disturbance can be either direct strike and indirect strike. In this research will be installed of new arrester with new innovation technology that is Multi Chamber Arrester (MCA) that used air gap and air pressure in the chamber as its technology. The MCA has a function to protect overhead lines from lightning, especially 20 kV medium voltage. The MCA protection system will be tested by rocket triggered lightning, the rocket platform is 81 meters from the Hercules Feeder in PLN Karawang Area. Calculation and analysis due to indirect strike will be done in this research by using Rusck method. The results of the calculation and analysis shows the performance of MCA capable to stop the peak current due to lightning induction current up to 16 kA and the comparison of MCA performance result has done at PLN Serpong Area and shows the MCA performance can reduce 36% line fault of Ruko Feeder after two years MCA installed.
format Theses
author Eka Widodo, Krismanto
spellingShingle Eka Widodo, Krismanto
INDUCED VOLTAGE ON MEDIUM OVERHEAD LINE CAUSED BY NEARBY STRIKE FROM ROCKET TRIGGERED LIGHTNING
author_facet Eka Widodo, Krismanto
author_sort Eka Widodo, Krismanto
title INDUCED VOLTAGE ON MEDIUM OVERHEAD LINE CAUSED BY NEARBY STRIKE FROM ROCKET TRIGGERED LIGHTNING
title_short INDUCED VOLTAGE ON MEDIUM OVERHEAD LINE CAUSED BY NEARBY STRIKE FROM ROCKET TRIGGERED LIGHTNING
title_full INDUCED VOLTAGE ON MEDIUM OVERHEAD LINE CAUSED BY NEARBY STRIKE FROM ROCKET TRIGGERED LIGHTNING
title_fullStr INDUCED VOLTAGE ON MEDIUM OVERHEAD LINE CAUSED BY NEARBY STRIKE FROM ROCKET TRIGGERED LIGHTNING
title_full_unstemmed INDUCED VOLTAGE ON MEDIUM OVERHEAD LINE CAUSED BY NEARBY STRIKE FROM ROCKET TRIGGERED LIGHTNING
title_sort induced voltage on medium overhead line caused by nearby strike from rocket triggered lightning
url https://digilib.itb.ac.id/gdl/view/22844
_version_ 1821120897052835840