Design and Unit Installation of Integrated Central Control System (ICCS) for Lubricants Performance Testing

Lubricant is needed because it's necessity in fossil-fueled vehicle, which includes four-wheeled vehicle. Lubricant performance test for lubricant standardization is needed considering the amount of lubricant types sold in Indonesia. <br /> <br /> Lubrication standardization can be...

Full description

Saved in:
Bibliographic Details
Main Author: Aliya Rahmamira-13114016, Adita
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/25010
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:25010
spelling id-itb.:250102018-09-21T15:35:34ZDesign and Unit Installation of Integrated Central Control System (ICCS) for Lubricants Performance Testing Aliya Rahmamira-13114016, Adita Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/25010 Lubricant is needed because it's necessity in fossil-fueled vehicle, which includes four-wheeled vehicle. Lubricant performance test for lubricant standardization is needed considering the amount of lubricant types sold in Indonesia. <br /> <br /> Lubrication standardization can be done through lubricant performance testing. Lubricant performance test is a testing process to determine lubricant performance in a working combustion engine. This test can be done independently or with support from other various supporting systems. One of the supporting systems that need to be designed is Integrated Central Control System (ICCS). <br /> <br /> ICCS is a lubricant testing support system that integrates all auxiliary testing devices. This integrated system consists of five subsystems, i.e. Diesel Fuel System, Gasoline Fuel System, Compressed Air System, Cooling Water System, Drain Monitoring System, and Exhaust System. ICCS works in parallel and series and can also be controlled manually and automatically. <br /> <br /> The design and installation of the ICCS unit is done with the aim that all subsystems can work in an integrated manner and can be controlled and monitored simultaneously in one display. The controller device used is a PLC as a flexible programming device. The Human Machine Interface (HMI) is a assistive communication device to facilitate operators in controlling and monitoring the testing process. <br /> text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Lubricant is needed because it's necessity in fossil-fueled vehicle, which includes four-wheeled vehicle. Lubricant performance test for lubricant standardization is needed considering the amount of lubricant types sold in Indonesia. <br /> <br /> Lubrication standardization can be done through lubricant performance testing. Lubricant performance test is a testing process to determine lubricant performance in a working combustion engine. This test can be done independently or with support from other various supporting systems. One of the supporting systems that need to be designed is Integrated Central Control System (ICCS). <br /> <br /> ICCS is a lubricant testing support system that integrates all auxiliary testing devices. This integrated system consists of five subsystems, i.e. Diesel Fuel System, Gasoline Fuel System, Compressed Air System, Cooling Water System, Drain Monitoring System, and Exhaust System. ICCS works in parallel and series and can also be controlled manually and automatically. <br /> <br /> The design and installation of the ICCS unit is done with the aim that all subsystems can work in an integrated manner and can be controlled and monitored simultaneously in one display. The controller device used is a PLC as a flexible programming device. The Human Machine Interface (HMI) is a assistive communication device to facilitate operators in controlling and monitoring the testing process. <br />
format Final Project
author Aliya Rahmamira-13114016, Adita
spellingShingle Aliya Rahmamira-13114016, Adita
Design and Unit Installation of Integrated Central Control System (ICCS) for Lubricants Performance Testing
author_facet Aliya Rahmamira-13114016, Adita
author_sort Aliya Rahmamira-13114016, Adita
title Design and Unit Installation of Integrated Central Control System (ICCS) for Lubricants Performance Testing
title_short Design and Unit Installation of Integrated Central Control System (ICCS) for Lubricants Performance Testing
title_full Design and Unit Installation of Integrated Central Control System (ICCS) for Lubricants Performance Testing
title_fullStr Design and Unit Installation of Integrated Central Control System (ICCS) for Lubricants Performance Testing
title_full_unstemmed Design and Unit Installation of Integrated Central Control System (ICCS) for Lubricants Performance Testing
title_sort design and unit installation of integrated central control system (iccs) for lubricants performance testing
url https://digilib.itb.ac.id/gdl/view/25010
_version_ 1822020563612205056