FOUNDATION AND EXCAVATION RETAINING WALL DESIGN OF UPPER MIDDLE CLASS APARTMENT, FATMAWATI CITY CENTER – JAKARTA

<p align="justify">Fatmawati City Center is an upper middle class apartment that consists of 27 floors functioned as office, lifestyle center, and condominium, with 4 basement floors provided parking area at superblock area of Fatmawati City Center, South Jakarta. The design of found...

Full description

Saved in:
Bibliographic Details
Main Author: SYAHADATIN, AMALIA
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/25438
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:25438
spelling id-itb.:254382018-07-02T09:22:46ZFOUNDATION AND EXCAVATION RETAINING WALL DESIGN OF UPPER MIDDLE CLASS APARTMENT, FATMAWATI CITY CENTER – JAKARTA SYAHADATIN, AMALIA Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/25438 <p align="justify">Fatmawati City Center is an upper middle class apartment that consists of 27 floors functioned as office, lifestyle center, and condominium, with 4 basement floors provided parking area at superblock area of Fatmawati City Center, South Jakarta. The design of foundation was choosen from two alternatives such as bore pile foundation and raft-pile foundation which met the design criteria. The design criteria include the foundation bearing capacity and foundation settlement. The axial bearing capacity determined by using manual calculation based on Meyerhof and the lateral bearing capacity determined by using LPILE software. After obtaining the foundation configuration based on soil bearing capacity, the foundation used is raft-pile foundation because it is more efficient. The raft-pile foundation consists of 1 m and 2 m thick raft, and 80 cm diameter bore pile with 10 m long as much 375 piles. The settlement analysis was calculated using SETTLE 3D and SAFE software. The design of excavation retaining wall used diaphragm wall with ground anchor reinforcement that qualified the design criteria include wall deflection, excavation retaining wall safety factor, and ground anchor safety factor. The analysis of excavation retaining wall used PLAXIS 2D software with stages construction consists of diaphragm wall installation, 5 excavation stages, and 3 ground anchors installation. The excavation retaining wall has 80 cm thickness, 25 m depth of penetration, and 3 ground anchors installed at -5 m, -8 m, and -11 m elevation with 347 kN prestress force assigned. The reinforcement design of foundation and diaphragm wall accordanced with the regulation of SNI 03-28472013 about The Planning and Designing of Concrete Structures for Bulding Construction. The design results are in the form of detailed drawings and Bill of Quantity (BoQ), also technical specifications. <p align="justify"> text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description <p align="justify">Fatmawati City Center is an upper middle class apartment that consists of 27 floors functioned as office, lifestyle center, and condominium, with 4 basement floors provided parking area at superblock area of Fatmawati City Center, South Jakarta. The design of foundation was choosen from two alternatives such as bore pile foundation and raft-pile foundation which met the design criteria. The design criteria include the foundation bearing capacity and foundation settlement. The axial bearing capacity determined by using manual calculation based on Meyerhof and the lateral bearing capacity determined by using LPILE software. After obtaining the foundation configuration based on soil bearing capacity, the foundation used is raft-pile foundation because it is more efficient. The raft-pile foundation consists of 1 m and 2 m thick raft, and 80 cm diameter bore pile with 10 m long as much 375 piles. The settlement analysis was calculated using SETTLE 3D and SAFE software. The design of excavation retaining wall used diaphragm wall with ground anchor reinforcement that qualified the design criteria include wall deflection, excavation retaining wall safety factor, and ground anchor safety factor. The analysis of excavation retaining wall used PLAXIS 2D software with stages construction consists of diaphragm wall installation, 5 excavation stages, and 3 ground anchors installation. The excavation retaining wall has 80 cm thickness, 25 m depth of penetration, and 3 ground anchors installed at -5 m, -8 m, and -11 m elevation with 347 kN prestress force assigned. The reinforcement design of foundation and diaphragm wall accordanced with the regulation of SNI 03-28472013 about The Planning and Designing of Concrete Structures for Bulding Construction. The design results are in the form of detailed drawings and Bill of Quantity (BoQ), also technical specifications. <p align="justify">
format Final Project
author SYAHADATIN, AMALIA
spellingShingle SYAHADATIN, AMALIA
FOUNDATION AND EXCAVATION RETAINING WALL DESIGN OF UPPER MIDDLE CLASS APARTMENT, FATMAWATI CITY CENTER – JAKARTA
author_facet SYAHADATIN, AMALIA
author_sort SYAHADATIN, AMALIA
title FOUNDATION AND EXCAVATION RETAINING WALL DESIGN OF UPPER MIDDLE CLASS APARTMENT, FATMAWATI CITY CENTER – JAKARTA
title_short FOUNDATION AND EXCAVATION RETAINING WALL DESIGN OF UPPER MIDDLE CLASS APARTMENT, FATMAWATI CITY CENTER – JAKARTA
title_full FOUNDATION AND EXCAVATION RETAINING WALL DESIGN OF UPPER MIDDLE CLASS APARTMENT, FATMAWATI CITY CENTER – JAKARTA
title_fullStr FOUNDATION AND EXCAVATION RETAINING WALL DESIGN OF UPPER MIDDLE CLASS APARTMENT, FATMAWATI CITY CENTER – JAKARTA
title_full_unstemmed FOUNDATION AND EXCAVATION RETAINING WALL DESIGN OF UPPER MIDDLE CLASS APARTMENT, FATMAWATI CITY CENTER – JAKARTA
title_sort foundation and excavation retaining wall design of upper middle class apartment, fatmawati city center ãƒâ€šã‚– jakarta
url https://digilib.itb.ac.id/gdl/view/25438
_version_ 1822921555745701888