SAFETY STUDY OF THE RADIATION PROTECTION BASED ON CALCULATION AND MEASUREMENT AT THE LINEAR ACCELERATOR ROOM AT THE ONKOLOGI INSTALLATION
Linear accelerator room installation design is a requirement for radiation safety in terms of radiation protection. Radiation protection aims to reduce harmful effects caused by radiation by determining dose limit values. This final project report is intended to evaluate the design of Linac room and...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/29773 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:29773 |
---|---|
spelling |
id-itb.:297732018-02-25T04:01:02ZSAFETY STUDY OF THE RADIATION PROTECTION BASED ON CALCULATION AND MEASUREMENT AT THE LINEAR ACCELERATOR ROOM AT THE ONKOLOGI INSTALLATION Atinal Khusna (NIM: 10213020), Nur Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/29773 Linear accelerator room installation design is a requirement for radiation safety in terms of radiation protection. Radiation protection aims to reduce harmful effects caused by radiation by determining dose limit values. This final project report is intended to evaluate the design of Linac room and compare it with the result of calculation using method based on the NCRP Report No. 151. Other than calculation evaluation, author also performed radiation survey using GM counter to obtain dose rate value measured outside the Linac room. Calculation result includes the thickness of primary and secondary barriers, equivalent dose rate on the walls and doors, and TADR. By observing the Linac blueprint, barrier thicknesses of the blueprint are satisfy the result of barrier calculation, equivalent dose rate on walls are less than dose limits, TADR calculation results are less than the TADR limit value, and total calculation results of dose rate on the doors exceed the International standard of dose limit. The measurement dose rate outside the Linac room are below the radiation limits per week, with workload 1000 Gy/week. text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
description |
Linear accelerator room installation design is a requirement for radiation safety in terms of radiation protection. Radiation protection aims to reduce harmful effects caused by radiation by determining dose limit values. This final project report is intended to evaluate the design of Linac room and compare it with the result of calculation using method based on the NCRP Report No. 151. Other than calculation evaluation, author also performed radiation survey using GM counter to obtain dose rate value measured outside the Linac room. Calculation result includes the thickness of primary and secondary barriers, equivalent dose rate on the walls and doors, and TADR. By observing the Linac blueprint, barrier thicknesses of the blueprint are satisfy the result of barrier calculation, equivalent dose rate on walls are less than dose limits, TADR calculation results are less than the TADR limit value, and total calculation results of dose rate on the doors exceed the International standard of dose limit. The measurement dose rate outside the Linac room are below the radiation limits per week, with workload 1000 Gy/week. |
format |
Final Project |
author |
Atinal Khusna (NIM: 10213020), Nur |
spellingShingle |
Atinal Khusna (NIM: 10213020), Nur SAFETY STUDY OF THE RADIATION PROTECTION BASED ON CALCULATION AND MEASUREMENT AT THE LINEAR ACCELERATOR ROOM AT THE ONKOLOGI INSTALLATION |
author_facet |
Atinal Khusna (NIM: 10213020), Nur |
author_sort |
Atinal Khusna (NIM: 10213020), Nur |
title |
SAFETY STUDY OF THE RADIATION PROTECTION BASED ON CALCULATION AND MEASUREMENT AT THE LINEAR ACCELERATOR ROOM AT THE ONKOLOGI INSTALLATION |
title_short |
SAFETY STUDY OF THE RADIATION PROTECTION BASED ON CALCULATION AND MEASUREMENT AT THE LINEAR ACCELERATOR ROOM AT THE ONKOLOGI INSTALLATION |
title_full |
SAFETY STUDY OF THE RADIATION PROTECTION BASED ON CALCULATION AND MEASUREMENT AT THE LINEAR ACCELERATOR ROOM AT THE ONKOLOGI INSTALLATION |
title_fullStr |
SAFETY STUDY OF THE RADIATION PROTECTION BASED ON CALCULATION AND MEASUREMENT AT THE LINEAR ACCELERATOR ROOM AT THE ONKOLOGI INSTALLATION |
title_full_unstemmed |
SAFETY STUDY OF THE RADIATION PROTECTION BASED ON CALCULATION AND MEASUREMENT AT THE LINEAR ACCELERATOR ROOM AT THE ONKOLOGI INSTALLATION |
title_sort |
safety study of the radiation protection based on calculation and measurement at the linear accelerator room at the onkologi installation |
url |
https://digilib.itb.ac.id/gdl/view/29773 |
_version_ |
1822923025215913984 |