PEMBUATAN DAN KARAKTERISASI ELEKTRODE SELEKTIF ION HIDROGEN DENGAN BAHAN AKTIF ANTIMONI

Composite electrode for the measurement of hydrogen ion in solution has been made from antimony, graphite, and paraffin. The dynamic range of the electrode is between pH 1.00 - 11.00 with the slopes of -51,2 ± 0.5 mV/pH and the respon time between 20 - 120 seconds. The electrode can be used for 150...

Full description

Saved in:
Bibliographic Details
Main Author: Masykur, Abu
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/2985
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:2985
spelling id-itb.:29852005-09-30T15:23:23ZPEMBUATAN DAN KARAKTERISASI ELEKTRODE SELEKTIF ION HIDROGEN DENGAN BAHAN AKTIF ANTIMONI Masykur, Abu Indonesia Theses INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/2985 Composite electrode for the measurement of hydrogen ion in solution has been made from antimony, graphite, and paraffin. The dynamic range of the electrode is between pH 1.00 - 11.00 with the slopes of -51,2 ± 0.5 mV/pH and the respon time between 20 - 120 seconds. The electrode can be used for 150 measurements, as long as the surface of the electrode can be renewed. The electrode potential decreases with the slope of 1,6±0,05 rnV/°C as the temperature of the solution increases. Oxidizing and reducing agent affects the performance of the electrode, due to their ability to reduce or oxidize the active agent of the electrode. The used of this electrode for potentiometric titration and direct measurement of solution pH shows no different with glass electrode text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Composite electrode for the measurement of hydrogen ion in solution has been made from antimony, graphite, and paraffin. The dynamic range of the electrode is between pH 1.00 - 11.00 with the slopes of -51,2 ± 0.5 mV/pH and the respon time between 20 - 120 seconds. The electrode can be used for 150 measurements, as long as the surface of the electrode can be renewed. The electrode potential decreases with the slope of 1,6±0,05 rnV/°C as the temperature of the solution increases. Oxidizing and reducing agent affects the performance of the electrode, due to their ability to reduce or oxidize the active agent of the electrode. The used of this electrode for potentiometric titration and direct measurement of solution pH shows no different with glass electrode
format Theses
author Masykur, Abu
spellingShingle Masykur, Abu
PEMBUATAN DAN KARAKTERISASI ELEKTRODE SELEKTIF ION HIDROGEN DENGAN BAHAN AKTIF ANTIMONI
author_facet Masykur, Abu
author_sort Masykur, Abu
title PEMBUATAN DAN KARAKTERISASI ELEKTRODE SELEKTIF ION HIDROGEN DENGAN BAHAN AKTIF ANTIMONI
title_short PEMBUATAN DAN KARAKTERISASI ELEKTRODE SELEKTIF ION HIDROGEN DENGAN BAHAN AKTIF ANTIMONI
title_full PEMBUATAN DAN KARAKTERISASI ELEKTRODE SELEKTIF ION HIDROGEN DENGAN BAHAN AKTIF ANTIMONI
title_fullStr PEMBUATAN DAN KARAKTERISASI ELEKTRODE SELEKTIF ION HIDROGEN DENGAN BAHAN AKTIF ANTIMONI
title_full_unstemmed PEMBUATAN DAN KARAKTERISASI ELEKTRODE SELEKTIF ION HIDROGEN DENGAN BAHAN AKTIF ANTIMONI
title_sort pembuatan dan karakterisasi elektrode selektif ion hidrogen dengan bahan aktif antimoni
url https://digilib.itb.ac.id/gdl/view/2985
_version_ 1820663311288500224