THE STUDY OF INTRA-OPERATIVE RADIATION THERAPY (IORT) ON CONVENTIONAL LINAC BASED ON ELECTRON’S PERCENTAGE DEPTH DOSE (PDD) AND DOSE PROFILE

<p align="justify">Intra-Operative Radiation Therapy (IORT) is a radiation therapy which is performed directly during surgery. This technique delivers a high dose of electron radiation in a single exposure by mobile technology of linac. This study focuses on modelling IORT technique...

Full description

Saved in:
Bibliographic Details
Main Author: SUCI ZASNEDA (NIM : 20213047), SABRIANI
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/30755
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:30755
spelling id-itb.:307552018-08-06T13:40:31ZTHE STUDY OF INTRA-OPERATIVE RADIATION THERAPY (IORT) ON CONVENTIONAL LINAC BASED ON ELECTRON’S PERCENTAGE DEPTH DOSE (PDD) AND DOSE PROFILE SUCI ZASNEDA (NIM : 20213047), SABRIANI Indonesia Theses INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/30755 <p align="justify">Intra-Operative Radiation Therapy (IORT) is a radiation therapy which is performed directly during surgery. This technique delivers a high dose of electron radiation in a single exposure by mobile technology of linac. This study focuses on modelling IORT technique for conventional Linac by using Monte Carlo EGSnrc code. The simulation consist of : (1) modelling the head accelerator for 10 MeV electron beam without the applicator by using BEAMnrc, (2) modelling the applicator for IORT purpose with PMMA materials, 0.5 cm of thickness and 10 cm of diameter, and SSD 100 cm and 80 cm with field size 4, 6, 8, and 10 cm (3) simulated 10 MeV electron beam in a water panthom with the size 40 cm x 40 cm x 40 cm. The simulation using BEAMnrc shows that there was a bremsstrahlung contamination at energy spectrum 0.5 MeV, and the electrons beam scattered by 10 degrees. The result of simulation using DOSXYZnrc has an excellent dose distribution with 5 cm maximum depth, &#8804; 3% of flatness dose profile, and the size of penumbra is about 12 mm - 14 mm particularly (within the tolerance limits of permitted).<p align="justify"> text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description <p align="justify">Intra-Operative Radiation Therapy (IORT) is a radiation therapy which is performed directly during surgery. This technique delivers a high dose of electron radiation in a single exposure by mobile technology of linac. This study focuses on modelling IORT technique for conventional Linac by using Monte Carlo EGSnrc code. The simulation consist of : (1) modelling the head accelerator for 10 MeV electron beam without the applicator by using BEAMnrc, (2) modelling the applicator for IORT purpose with PMMA materials, 0.5 cm of thickness and 10 cm of diameter, and SSD 100 cm and 80 cm with field size 4, 6, 8, and 10 cm (3) simulated 10 MeV electron beam in a water panthom with the size 40 cm x 40 cm x 40 cm. The simulation using BEAMnrc shows that there was a bremsstrahlung contamination at energy spectrum 0.5 MeV, and the electrons beam scattered by 10 degrees. The result of simulation using DOSXYZnrc has an excellent dose distribution with 5 cm maximum depth, &#8804; 3% of flatness dose profile, and the size of penumbra is about 12 mm - 14 mm particularly (within the tolerance limits of permitted).<p align="justify">
format Theses
author SUCI ZASNEDA (NIM : 20213047), SABRIANI
spellingShingle SUCI ZASNEDA (NIM : 20213047), SABRIANI
THE STUDY OF INTRA-OPERATIVE RADIATION THERAPY (IORT) ON CONVENTIONAL LINAC BASED ON ELECTRON’S PERCENTAGE DEPTH DOSE (PDD) AND DOSE PROFILE
author_facet SUCI ZASNEDA (NIM : 20213047), SABRIANI
author_sort SUCI ZASNEDA (NIM : 20213047), SABRIANI
title THE STUDY OF INTRA-OPERATIVE RADIATION THERAPY (IORT) ON CONVENTIONAL LINAC BASED ON ELECTRON’S PERCENTAGE DEPTH DOSE (PDD) AND DOSE PROFILE
title_short THE STUDY OF INTRA-OPERATIVE RADIATION THERAPY (IORT) ON CONVENTIONAL LINAC BASED ON ELECTRON’S PERCENTAGE DEPTH DOSE (PDD) AND DOSE PROFILE
title_full THE STUDY OF INTRA-OPERATIVE RADIATION THERAPY (IORT) ON CONVENTIONAL LINAC BASED ON ELECTRON’S PERCENTAGE DEPTH DOSE (PDD) AND DOSE PROFILE
title_fullStr THE STUDY OF INTRA-OPERATIVE RADIATION THERAPY (IORT) ON CONVENTIONAL LINAC BASED ON ELECTRON’S PERCENTAGE DEPTH DOSE (PDD) AND DOSE PROFILE
title_full_unstemmed THE STUDY OF INTRA-OPERATIVE RADIATION THERAPY (IORT) ON CONVENTIONAL LINAC BASED ON ELECTRON’S PERCENTAGE DEPTH DOSE (PDD) AND DOSE PROFILE
title_sort study of intra-operative radiation therapy (iort) on conventional linac based on electronãƒâ€šã‚’s percentage depth dose (pdd) and dose profile
url https://digilib.itb.ac.id/gdl/view/30755
_version_ 1821995853118701568