MODIFICATION OF CARBON PASTE ELECTRODE WITH NON-IMPRINTED POLY(GLYCINE) AND IMPRINTED POLY(GLYCINE) FOR VOLTAMMETRIC DETERMINATION OF PARACETAMOL

Paracetamol is an analgesic and antipyretic drug that’s used to treat various diseases such as headaches, back pain, arthritis, toothache and pain after surgery. However, if it consumed in excess it can cause liver damage and kidney disorders. In this research, carbón paste electrode modified...

Full description

Saved in:
Bibliographic Details
Main Author: MAESAROH (NIM:10512024), SITI
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/30993
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:30993
spelling id-itb.:309932018-09-21T08:10:16ZMODIFICATION OF CARBON PASTE ELECTRODE WITH NON-IMPRINTED POLY(GLYCINE) AND IMPRINTED POLY(GLYCINE) FOR VOLTAMMETRIC DETERMINATION OF PARACETAMOL MAESAROH (NIM:10512024), SITI Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/30993 Paracetamol is an analgesic and antipyretic drug that’s used to treat various diseases such as headaches, back pain, arthritis, toothache and pain after surgery. However, if it consumed in excess it can cause liver damage and kidney disorders. In this research, carbón paste electrode modified with non-imprinted poly(glycine) and molecularly imprinted poly(glycine) (CPE-NIP-MIP) for voltammetric determination of paracetamol had been succesfuly developed. Electropolymerization was carried out using 5 cyclic with cyclic voltammetry techniques in the potential range of -0.5 V to 1.8 V and scan rate of 100 mV / s in a phosphate buffer solution of pH 7. To produce MIP, paracetamol was removed from polymer matrix by technique, amount of cyclic and range as same as electropolymerization process in a phosphate buffer solution of pH 7. The measurements of paracetamol was performed using diferential pulse voltammetry (DPV) in HCLO4 0,1 M solution as supporting electrolyte. Repeated measurement of paracetamol 0.1 mM resulted in RSD of 11.10 % (n = 40). CPE-NIP-MIP calibration curve provides a linear response in the concentration range of 20 μM - 100 μM with the limit of detection of 1.98 μM. Determination of paracetamol in 4 samples of commercial drugs resulted in percent recovery between 97.18% and 103,64%. Measurements using UV spectrophotometry show results that are not much different text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Paracetamol is an analgesic and antipyretic drug that’s used to treat various diseases such as headaches, back pain, arthritis, toothache and pain after surgery. However, if it consumed in excess it can cause liver damage and kidney disorders. In this research, carbón paste electrode modified with non-imprinted poly(glycine) and molecularly imprinted poly(glycine) (CPE-NIP-MIP) for voltammetric determination of paracetamol had been succesfuly developed. Electropolymerization was carried out using 5 cyclic with cyclic voltammetry techniques in the potential range of -0.5 V to 1.8 V and scan rate of 100 mV / s in a phosphate buffer solution of pH 7. To produce MIP, paracetamol was removed from polymer matrix by technique, amount of cyclic and range as same as electropolymerization process in a phosphate buffer solution of pH 7. The measurements of paracetamol was performed using diferential pulse voltammetry (DPV) in HCLO4 0,1 M solution as supporting electrolyte. Repeated measurement of paracetamol 0.1 mM resulted in RSD of 11.10 % (n = 40). CPE-NIP-MIP calibration curve provides a linear response in the concentration range of 20 μM - 100 μM with the limit of detection of 1.98 μM. Determination of paracetamol in 4 samples of commercial drugs resulted in percent recovery between 97.18% and 103,64%. Measurements using UV spectrophotometry show results that are not much different
format Final Project
author MAESAROH (NIM:10512024), SITI
spellingShingle MAESAROH (NIM:10512024), SITI
MODIFICATION OF CARBON PASTE ELECTRODE WITH NON-IMPRINTED POLY(GLYCINE) AND IMPRINTED POLY(GLYCINE) FOR VOLTAMMETRIC DETERMINATION OF PARACETAMOL
author_facet MAESAROH (NIM:10512024), SITI
author_sort MAESAROH (NIM:10512024), SITI
title MODIFICATION OF CARBON PASTE ELECTRODE WITH NON-IMPRINTED POLY(GLYCINE) AND IMPRINTED POLY(GLYCINE) FOR VOLTAMMETRIC DETERMINATION OF PARACETAMOL
title_short MODIFICATION OF CARBON PASTE ELECTRODE WITH NON-IMPRINTED POLY(GLYCINE) AND IMPRINTED POLY(GLYCINE) FOR VOLTAMMETRIC DETERMINATION OF PARACETAMOL
title_full MODIFICATION OF CARBON PASTE ELECTRODE WITH NON-IMPRINTED POLY(GLYCINE) AND IMPRINTED POLY(GLYCINE) FOR VOLTAMMETRIC DETERMINATION OF PARACETAMOL
title_fullStr MODIFICATION OF CARBON PASTE ELECTRODE WITH NON-IMPRINTED POLY(GLYCINE) AND IMPRINTED POLY(GLYCINE) FOR VOLTAMMETRIC DETERMINATION OF PARACETAMOL
title_full_unstemmed MODIFICATION OF CARBON PASTE ELECTRODE WITH NON-IMPRINTED POLY(GLYCINE) AND IMPRINTED POLY(GLYCINE) FOR VOLTAMMETRIC DETERMINATION OF PARACETAMOL
title_sort modification of carbon paste electrode with non-imprinted poly(glycine) and imprinted poly(glycine) for voltammetric determination of paracetamol
url https://digilib.itb.ac.id/gdl/view/30993
_version_ 1821995931629780992