Study of Paracetamol Analysis by Voltammetry on Filter Paper with Carbon Paste Electrode and Modified Carbon Paste Electrodes
Paracetamol is an effective and safe drug to reduce fever and pain. Excessive use of <br /> <br /> paracetamol can cause toxic metabolites to accumulate and cause kidney or liver damage. <br /> <br /> This research uses a carbon paste electrode modified by molecularly imprint...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/31736 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:31736 |
---|---|
spelling |
id-itb.:317362018-09-21T08:25:45ZStudy of Paracetamol Analysis by Voltammetry on Filter Paper with Carbon Paste Electrode and Modified Carbon Paste Electrodes NATALINA ROULY S (NIM:10514027), YESSY Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/31736 Paracetamol is an effective and safe drug to reduce fever and pain. Excessive use of <br /> <br /> paracetamol can cause toxic metabolites to accumulate and cause kidney or liver damage. <br /> <br /> This research uses a carbon paste electrode modified by molecularly imprinted poly <br /> <br /> (glutamic acid) for the determination of paracetamol by voltammetry by filter paper <br /> <br /> method. In the manufacture of MIP modified carbon paste electrodes <br /> <br /> electropolymerization was carried out in a solution containing paracetamol, glutamic acid <br /> <br /> and HClO4 0.1 using cyclic voltammetry techniques at a potential range of -0.8 - 2.0 V. <br /> <br /> Measurement of paracetamol by voltammetry by filter paper method use three working <br /> <br /> electrodes namely, CPE, CPE-NIP and CPE-MIP. Repeated measurement results and linearity <br /> <br /> tests show that the suitable electrodes for filter paper methods are CPE. The calibration <br /> <br /> curve provides a linear area in the range 0.1-1 mM with a detection limit of 0.314 mM. The <br /> <br /> three working electrodes have been used to determine the paracetamol content contained <br /> <br /> in commercial drug samples. The working electrode that provides the best percent recovery <br /> <br /> is CPE. text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
description |
Paracetamol is an effective and safe drug to reduce fever and pain. Excessive use of <br />
<br />
paracetamol can cause toxic metabolites to accumulate and cause kidney or liver damage. <br />
<br />
This research uses a carbon paste electrode modified by molecularly imprinted poly <br />
<br />
(glutamic acid) for the determination of paracetamol by voltammetry by filter paper <br />
<br />
method. In the manufacture of MIP modified carbon paste electrodes <br />
<br />
electropolymerization was carried out in a solution containing paracetamol, glutamic acid <br />
<br />
and HClO4 0.1 using cyclic voltammetry techniques at a potential range of -0.8 - 2.0 V. <br />
<br />
Measurement of paracetamol by voltammetry by filter paper method use three working <br />
<br />
electrodes namely, CPE, CPE-NIP and CPE-MIP. Repeated measurement results and linearity <br />
<br />
tests show that the suitable electrodes for filter paper methods are CPE. The calibration <br />
<br />
curve provides a linear area in the range 0.1-1 mM with a detection limit of 0.314 mM. The <br />
<br />
three working electrodes have been used to determine the paracetamol content contained <br />
<br />
in commercial drug samples. The working electrode that provides the best percent recovery <br />
<br />
is CPE. |
format |
Final Project |
author |
NATALINA ROULY S (NIM:10514027), YESSY |
spellingShingle |
NATALINA ROULY S (NIM:10514027), YESSY Study of Paracetamol Analysis by Voltammetry on Filter Paper with Carbon Paste Electrode and Modified Carbon Paste Electrodes |
author_facet |
NATALINA ROULY S (NIM:10514027), YESSY |
author_sort |
NATALINA ROULY S (NIM:10514027), YESSY |
title |
Study of Paracetamol Analysis by Voltammetry on Filter Paper with Carbon Paste Electrode and Modified Carbon Paste Electrodes |
title_short |
Study of Paracetamol Analysis by Voltammetry on Filter Paper with Carbon Paste Electrode and Modified Carbon Paste Electrodes |
title_full |
Study of Paracetamol Analysis by Voltammetry on Filter Paper with Carbon Paste Electrode and Modified Carbon Paste Electrodes |
title_fullStr |
Study of Paracetamol Analysis by Voltammetry on Filter Paper with Carbon Paste Electrode and Modified Carbon Paste Electrodes |
title_full_unstemmed |
Study of Paracetamol Analysis by Voltammetry on Filter Paper with Carbon Paste Electrode and Modified Carbon Paste Electrodes |
title_sort |
study of paracetamol analysis by voltammetry on filter paper with carbon paste electrode and modified carbon paste electrodes |
url |
https://digilib.itb.ac.id/gdl/view/31736 |
_version_ |
1822267855400337408 |