DETERMINATION METALS IN PM2, 5 USING X-RAY SPECTROSCOPY (XRF) AND GRAPHITE FURNACES ATOMIC ABSORPTION SPECTROMETRY (GFAAS)

The purpose of this study was to evaluate the accuracy and precision of the determination of the elements (Al, As, Ca, Cu, Cr, Fe, K, Mg, Mn, Ni, Pb, S, Si, Ti, V and Zn) in the particulate air PM2,5 captured by nucleopore polycarbonate filter using the measurement techniques of X-ray fluorescence...

Full description

Saved in:
Bibliographic Details
Main Author: Basit Febrian, Muhamad
Format: Theses
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/34417
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:34417
spelling id-itb.:344172019-02-08T10:50:08ZDETERMINATION METALS IN PM2, 5 USING X-RAY SPECTROSCOPY (XRF) AND GRAPHITE FURNACES ATOMIC ABSORPTION SPECTROMETRY (GFAAS) Basit Febrian, Muhamad Kimia Indonesia Theses Particulate Air PM2,5, XRF, GFAAS INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/34417 The purpose of this study was to evaluate the accuracy and precision of the determination of the elements (Al, As, Ca, Cu, Cr, Fe, K, Mg, Mn, Ni, Pb, S, Si, Ti, V and Zn) in the particulate air PM2,5 captured by nucleopore polycarbonate filter using the measurement techniques of X-ray fluorescence (XRF). Cr, Cu, Ni and Pb results were compared using Atomic Absorption Spectrometry - Graphite furnace (GFAAS) technique. The accuracy check of XRF measurements was performed using SRM 2738 and among most of the elements listed in the certificate give recovery value in 100% ± 10% range. Ten samples of PM2, 5 from Serpong area which have been captured by nucleopore polycarbonate filter were measured using XRF method with four replications and then relative standard deviation was calculated to get the repeatabilty of determination using XRF. 10 samples of PM2,5 from Serpong area as measured by XRF technique with four repetitions has shown good repeatability. Subsequently the filters digested and dissolved, then measured with GFAAS. The comparison of GFAAS and XRF results were not statistically significantly different. GFAAS test results were correlated with the corresponding XRF analytical signal in order to obtain a new calibration curve for the XRF method. Accuracy check of the new calibration curve from GFAAS was performed using SRM 2738 and the elements of Cr, Cu, Ni and Pb give 100% ± 10% recovery value. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
topic Kimia
spellingShingle Kimia
Basit Febrian, Muhamad
DETERMINATION METALS IN PM2, 5 USING X-RAY SPECTROSCOPY (XRF) AND GRAPHITE FURNACES ATOMIC ABSORPTION SPECTROMETRY (GFAAS)
description The purpose of this study was to evaluate the accuracy and precision of the determination of the elements (Al, As, Ca, Cu, Cr, Fe, K, Mg, Mn, Ni, Pb, S, Si, Ti, V and Zn) in the particulate air PM2,5 captured by nucleopore polycarbonate filter using the measurement techniques of X-ray fluorescence (XRF). Cr, Cu, Ni and Pb results were compared using Atomic Absorption Spectrometry - Graphite furnace (GFAAS) technique. The accuracy check of XRF measurements was performed using SRM 2738 and among most of the elements listed in the certificate give recovery value in 100% ± 10% range. Ten samples of PM2, 5 from Serpong area which have been captured by nucleopore polycarbonate filter were measured using XRF method with four replications and then relative standard deviation was calculated to get the repeatabilty of determination using XRF. 10 samples of PM2,5 from Serpong area as measured by XRF technique with four repetitions has shown good repeatability. Subsequently the filters digested and dissolved, then measured with GFAAS. The comparison of GFAAS and XRF results were not statistically significantly different. GFAAS test results were correlated with the corresponding XRF analytical signal in order to obtain a new calibration curve for the XRF method. Accuracy check of the new calibration curve from GFAAS was performed using SRM 2738 and the elements of Cr, Cu, Ni and Pb give 100% ± 10% recovery value.
format Theses
author Basit Febrian, Muhamad
author_facet Basit Febrian, Muhamad
author_sort Basit Febrian, Muhamad
title DETERMINATION METALS IN PM2, 5 USING X-RAY SPECTROSCOPY (XRF) AND GRAPHITE FURNACES ATOMIC ABSORPTION SPECTROMETRY (GFAAS)
title_short DETERMINATION METALS IN PM2, 5 USING X-RAY SPECTROSCOPY (XRF) AND GRAPHITE FURNACES ATOMIC ABSORPTION SPECTROMETRY (GFAAS)
title_full DETERMINATION METALS IN PM2, 5 USING X-RAY SPECTROSCOPY (XRF) AND GRAPHITE FURNACES ATOMIC ABSORPTION SPECTROMETRY (GFAAS)
title_fullStr DETERMINATION METALS IN PM2, 5 USING X-RAY SPECTROSCOPY (XRF) AND GRAPHITE FURNACES ATOMIC ABSORPTION SPECTROMETRY (GFAAS)
title_full_unstemmed DETERMINATION METALS IN PM2, 5 USING X-RAY SPECTROSCOPY (XRF) AND GRAPHITE FURNACES ATOMIC ABSORPTION SPECTROMETRY (GFAAS)
title_sort determination metals in pm2, 5 using x-ray spectroscopy (xrf) and graphite furnaces atomic absorption spectrometry (gfaas)
url https://digilib.itb.ac.id/gdl/view/34417
_version_ 1822924238123696128