PARTIAL DISCHARGE CHARACTERISTICS IN AIR INSULATION AND OIL INSULATION BY USING HFCT, RC DETECTOR AND LOOP ANTENNA
Insulation is a material that has an important role in electrical equipment to protect the electrical equipment. The good or bad quality of insulation has an impact on the quality of electrical equipment. One of the important ways to monitor the quality of insulation is to detect Partial Discharge (...
Saved in:
Main Author: | |
---|---|
Format: | Theses |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/36741 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:36741 |
---|---|
spelling |
id-itb.:367412019-03-14T15:08:55ZPARTIAL DISCHARGE CHARACTERISTICS IN AIR INSULATION AND OIL INSULATION BY USING HFCT, RC DETECTOR AND LOOP ANTENNA Stevano Sinurat, Michael Indonesia Theses Partial discharge (PD), insulation, RC Detector, HFCT (High Frequency Current Transformer), Loop Antenna. INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/36741 Insulation is a material that has an important role in electrical equipment to protect the electrical equipment. The good or bad quality of insulation has an impact on the quality of electrical equipment. One of the important ways to monitor the quality of insulation is to detect Partial Discharge (PD) on the equipment. Partial Discharge can occur in solid, liquid and gas insulation materials. Partial Discharge is very necessary to determine the value of Partial Discharge or Partial Discharge characteristics in equipment isolation and to know the condition of the electrical equipment. In general, these problems occur in electrical equipment that has long been used. 80% damage to electrical equipment is caused by problems with the isolation of high voltage equipment. This problem can disrupt the reliability of the equipment or the electrical system itself. So the electrical system requires monitoring to maintain the quality of the insulation. In this research, Partial Discharge measurements use electrical methods and non-electric methods. This electric method uses an HFCT sensor and an RC Detector sensor. Non-Electric Method Using a Loop Antenna sensor. Partial Discharge measurements are also carried out in two types of insulation, namely gas insulation (air) and liquid (oil) insulation. text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
description |
Insulation is a material that has an important role in electrical equipment to protect the electrical equipment. The good or bad quality of insulation has an impact on the quality of electrical equipment. One of the important ways to monitor the quality of insulation is to detect Partial Discharge (PD) on the equipment. Partial Discharge can occur in solid, liquid and gas insulation materials. Partial Discharge is very necessary to determine the value of Partial Discharge or Partial Discharge characteristics in equipment isolation and to know the condition of the electrical equipment. In general, these problems occur in electrical equipment that has long been used. 80% damage to electrical equipment is caused by problems with the isolation of high voltage equipment. This problem can disrupt the reliability of the equipment or the electrical system itself. So the electrical system requires monitoring to maintain the quality of the insulation. In this research, Partial Discharge measurements use electrical methods and non-electric methods. This electric method uses an HFCT sensor and an RC Detector sensor. Non-Electric Method Using a Loop Antenna sensor. Partial Discharge measurements are also carried out in two types of insulation, namely gas insulation (air) and liquid (oil) insulation. |
format |
Theses |
author |
Stevano Sinurat, Michael |
spellingShingle |
Stevano Sinurat, Michael PARTIAL DISCHARGE CHARACTERISTICS IN AIR INSULATION AND OIL INSULATION BY USING HFCT, RC DETECTOR AND LOOP ANTENNA |
author_facet |
Stevano Sinurat, Michael |
author_sort |
Stevano Sinurat, Michael |
title |
PARTIAL DISCHARGE CHARACTERISTICS IN AIR INSULATION AND OIL INSULATION BY USING HFCT, RC DETECTOR AND LOOP ANTENNA |
title_short |
PARTIAL DISCHARGE CHARACTERISTICS IN AIR INSULATION AND OIL INSULATION BY USING HFCT, RC DETECTOR AND LOOP ANTENNA |
title_full |
PARTIAL DISCHARGE CHARACTERISTICS IN AIR INSULATION AND OIL INSULATION BY USING HFCT, RC DETECTOR AND LOOP ANTENNA |
title_fullStr |
PARTIAL DISCHARGE CHARACTERISTICS IN AIR INSULATION AND OIL INSULATION BY USING HFCT, RC DETECTOR AND LOOP ANTENNA |
title_full_unstemmed |
PARTIAL DISCHARGE CHARACTERISTICS IN AIR INSULATION AND OIL INSULATION BY USING HFCT, RC DETECTOR AND LOOP ANTENNA |
title_sort |
partial discharge characteristics in air insulation and oil insulation by using hfct, rc detector and loop antenna |
url |
https://digilib.itb.ac.id/gdl/view/36741 |
_version_ |
1822924703898009600 |