H2S DISPERSION FROM GEOTHERMAL POWER PLANT WEST JAVA IN FLAT TERRAIN AND COMPLEX TERRAIN (AIR MODELING)
Geothermal energy is an eco-friendly energy that can be used as a power plant energy. Geothermal energy is obtained from the soil layer using borehole to a 3000 m depth. Geothermal exploitation is used by PT. X located in West Java as power plant source. The side effect of geothermal power plant pre...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Subjects: | |
Online Access: | https://digilib.itb.ac.id/gdl/view/36943 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:36943 |
---|---|
spelling |
id-itb.:369432019-03-18T08:43:15ZH2S DISPERSION FROM GEOTHERMAL POWER PLANT WEST JAVA IN FLAT TERRAIN AND COMPLEX TERRAIN (AIR MODELING) Ario Wibisono, Guntur Teknik saniter dan perkotaan; teknik perlindungan lingkungan Indonesia Final Project AERMOD, dispersion, geothermal, H2S, power plant INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/36943 Geothermal energy is an eco-friendly energy that can be used as a power plant energy. Geothermal energy is obtained from the soil layer using borehole to a 3000 m depth. Geothermal exploitation is used by PT. X located in West Java as power plant source. The side effect of geothermal power plant presence is the presence of gases such as H2S. H2S in high concentration can cause a decrease in air quality and bad impact to living organisms. In this study, H2S dispersion modeling in PT. X area is conducted. This study’s purpose is to know dispersion pattern and maximum concentration in atmosphere so it can be compared with ambient air standard quality. Modeling is conducted for annual and seasonal conditions with measurement time: 1 hour, 8 hour, and 24 hour. In addition, modeling is conducted in large domain (Garut regency) and small domain (5 km radius) in maximum emission rate and average emission rate. The result shows the highest concentration (in ppm) from maximum emission rate in condition (annual | dry | rain) is (0,518 | 0,255 | 0,518) for 24 hour time measurement, (0,873 | 0,799 | 0,873) for 8 hour measurement, and (5,236 | 4,274 | 5,236) for 1 hour measurement. Flat terrain and complex terrain effect will affect the pollutant dispersion pattern especially in the distribution area. The simulation result showed H2S concentration value in rain season is higher compared with dry season and the measured concentration value did not exceed the standard quality. text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
topic |
Teknik saniter dan perkotaan; teknik perlindungan lingkungan |
spellingShingle |
Teknik saniter dan perkotaan; teknik perlindungan lingkungan Ario Wibisono, Guntur H2S DISPERSION FROM GEOTHERMAL POWER PLANT WEST JAVA IN FLAT TERRAIN AND COMPLEX TERRAIN (AIR MODELING) |
description |
Geothermal energy is an eco-friendly energy that can be used as a power plant energy. Geothermal energy is obtained from the soil layer using borehole to a 3000 m depth. Geothermal exploitation is used by PT. X located in West Java as power plant source. The side effect of geothermal power plant presence is the presence of gases such as H2S. H2S in high concentration can cause a decrease in air quality and bad impact to living organisms. In this study, H2S dispersion modeling in PT. X area is conducted. This study’s purpose is to know dispersion pattern and maximum concentration in atmosphere so it can be compared with ambient air standard quality. Modeling is conducted for annual and seasonal conditions with measurement time: 1 hour, 8 hour, and 24 hour. In addition, modeling is conducted in large domain (Garut regency) and small domain (5 km radius) in maximum emission rate and average emission rate. The result shows the highest concentration (in ppm) from maximum emission rate in condition (annual | dry | rain) is (0,518 | 0,255 | 0,518) for 24 hour time measurement, (0,873 | 0,799 | 0,873) for 8 hour measurement, and (5,236 | 4,274 | 5,236) for 1 hour measurement. Flat terrain and complex terrain effect will affect the pollutant dispersion pattern especially in the distribution area. The simulation result showed H2S concentration value in rain season is higher compared with dry season and the measured concentration value did not exceed the standard quality. |
format |
Final Project |
author |
Ario Wibisono, Guntur |
author_facet |
Ario Wibisono, Guntur |
author_sort |
Ario Wibisono, Guntur |
title |
H2S DISPERSION FROM GEOTHERMAL POWER PLANT WEST JAVA IN FLAT TERRAIN AND COMPLEX TERRAIN (AIR MODELING) |
title_short |
H2S DISPERSION FROM GEOTHERMAL POWER PLANT WEST JAVA IN FLAT TERRAIN AND COMPLEX TERRAIN (AIR MODELING) |
title_full |
H2S DISPERSION FROM GEOTHERMAL POWER PLANT WEST JAVA IN FLAT TERRAIN AND COMPLEX TERRAIN (AIR MODELING) |
title_fullStr |
H2S DISPERSION FROM GEOTHERMAL POWER PLANT WEST JAVA IN FLAT TERRAIN AND COMPLEX TERRAIN (AIR MODELING) |
title_full_unstemmed |
H2S DISPERSION FROM GEOTHERMAL POWER PLANT WEST JAVA IN FLAT TERRAIN AND COMPLEX TERRAIN (AIR MODELING) |
title_sort |
h2s dispersion from geothermal power plant west java in flat terrain and complex terrain (air modeling) |
url |
https://digilib.itb.ac.id/gdl/view/36943 |
_version_ |
1822924774734561280 |