LIGHTNING PROTECTION SYSTEM ON OVERHEADLINE AND SUBSTATION EXTRA HIGH VOLTAGE 500 KV SUMATERA

Sumatra is an island that has a high lightning strike intensity each year. This is due to the fact that Sumatra Island is in the tropics and is in the Monsoon Wind path so the conditions for Cumulonimbus Clouds are easily fulfilled, namely up-draft, aerosols and humid air. The Sumatra 500 kV tran...

Full description

Saved in:
Bibliographic Details
Main Author: Irsal, Abdurrauf
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/40000
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:40000
spelling id-itb.:400002019-06-28T15:19:12ZLIGHTNING PROTECTION SYSTEM ON OVERHEADLINE AND SUBSTATION EXTRA HIGH VOLTAGE 500 KV SUMATERA Irsal, Abdurrauf Indonesia Final Project Lightning, Protection, Transmission Line, Substation, 500 kV, Sumatera. INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/40000 Sumatra is an island that has a high lightning strike intensity each year. This is due to the fact that Sumatra Island is in the tropics and is in the Monsoon Wind path so the conditions for Cumulonimbus Clouds are easily fulfilled, namely up-draft, aerosols and humid air. The Sumatra 500 kV transmission line and substation are being planned by the Perusahaan Listrik Negara (PLN). Lightning disturbances in the transmission line are divided into three, namely direct strikes on the tower, ground wire and phase wire. Direct strikes on the tower and ground wire can cause backflashover. While direct strikes on phase wires can cause shielding failure. Lightning disturbances in substations are divided into two, namely travelling waves from the transmission line and direct strikes at the substation. Travelling waves from the transmission line can cause flashover. While direct strikes on substations can cause backflashover and shielding failure. Therefore we need a lightning protection system in the transmission line and substation. The solution for direct strikes on the tower and substation is the extended mast terminal. The solution for direct strikes on ground wire and phase wire is a transmission line arrester. The solution for travelling wave from the transmission line is insulation coordination. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Sumatra is an island that has a high lightning strike intensity each year. This is due to the fact that Sumatra Island is in the tropics and is in the Monsoon Wind path so the conditions for Cumulonimbus Clouds are easily fulfilled, namely up-draft, aerosols and humid air. The Sumatra 500 kV transmission line and substation are being planned by the Perusahaan Listrik Negara (PLN). Lightning disturbances in the transmission line are divided into three, namely direct strikes on the tower, ground wire and phase wire. Direct strikes on the tower and ground wire can cause backflashover. While direct strikes on phase wires can cause shielding failure. Lightning disturbances in substations are divided into two, namely travelling waves from the transmission line and direct strikes at the substation. Travelling waves from the transmission line can cause flashover. While direct strikes on substations can cause backflashover and shielding failure. Therefore we need a lightning protection system in the transmission line and substation. The solution for direct strikes on the tower and substation is the extended mast terminal. The solution for direct strikes on ground wire and phase wire is a transmission line arrester. The solution for travelling wave from the transmission line is insulation coordination.
format Final Project
author Irsal, Abdurrauf
spellingShingle Irsal, Abdurrauf
LIGHTNING PROTECTION SYSTEM ON OVERHEADLINE AND SUBSTATION EXTRA HIGH VOLTAGE 500 KV SUMATERA
author_facet Irsal, Abdurrauf
author_sort Irsal, Abdurrauf
title LIGHTNING PROTECTION SYSTEM ON OVERHEADLINE AND SUBSTATION EXTRA HIGH VOLTAGE 500 KV SUMATERA
title_short LIGHTNING PROTECTION SYSTEM ON OVERHEADLINE AND SUBSTATION EXTRA HIGH VOLTAGE 500 KV SUMATERA
title_full LIGHTNING PROTECTION SYSTEM ON OVERHEADLINE AND SUBSTATION EXTRA HIGH VOLTAGE 500 KV SUMATERA
title_fullStr LIGHTNING PROTECTION SYSTEM ON OVERHEADLINE AND SUBSTATION EXTRA HIGH VOLTAGE 500 KV SUMATERA
title_full_unstemmed LIGHTNING PROTECTION SYSTEM ON OVERHEADLINE AND SUBSTATION EXTRA HIGH VOLTAGE 500 KV SUMATERA
title_sort lightning protection system on overheadline and substation extra high voltage 500 kv sumatera
url https://digilib.itb.ac.id/gdl/view/40000
_version_ 1821997953995243520