UJI VALIDITAS DAN RELIABILITAS BEBERAPA ALAT SWA-MONITOR KOMERSIAL UNTUK PEMERIKSAAN KADAR GLUKOSA DARAH DAN STUDI PENGARUH FAKTOR LOKASI PENGAMBILAN SAMPEL TERHADAP HASIL PENGUKURAN

Blood glucose monitoring is the most routine general checkup that been done independently by society regarding the incidence and prevalence of diabetes mellitus, particularly type 2. Recently, there are many self-monitoring devices for blood glucose, known as glucometer which globally market. Thi...

Full description

Saved in:
Bibliographic Details
Main Author: Oesricha Pakki, Tasya
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/40294
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:40294
spelling id-itb.:402942019-07-01T14:13:45ZUJI VALIDITAS DAN RELIABILITAS BEBERAPA ALAT SWA-MONITOR KOMERSIAL UNTUK PEMERIKSAAN KADAR GLUKOSA DARAH DAN STUDI PENGARUH FAKTOR LOKASI PENGAMBILAN SAMPEL TERHADAP HASIL PENGUKURAN Oesricha Pakki, Tasya Indonesia Final Project self-monitoring, glucometer, accuracy, reliability, right-left hand sampling. INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/40294 Blood glucose monitoring is the most routine general checkup that been done independently by society regarding the incidence and prevalence of diabetes mellitus, particularly type 2. Recently, there are many self-monitoring devices for blood glucose, known as glucometer which globally market. This study aimed to determine the validity of glucometers from several brands compared to the standard method spectrophotometer which is done by clinical laboratory, determine the reliability of the glucometers, examine the impact of the location of sample collection to the result of the blood glucose measurement and also developed the information and appropriate recommendation of glucometer usage. This study was done to five subjects to compare the measurement of blood glucose using the glucometers and spectrophotometer as a standard method. Within the same time, sample collection is done on vein and capillary blood. On this study, blood samples also been taken from five subjects for twelve times in a month on the right and left hand to examine the reliability and to see any effect from sampling location. The result is statistically analyzed using the paired t-test and Cronbach's alpha. The result showed that there are no significant differences between the measurement of blood glucose using glucometers and spectrophotometer with the p-value in brand ET, AC, and NES are 0.0934, 0.0766, 0.6926 (>0.05) respectively. Next, the result of blood glucose measurement between left and right hand is significantly different with P-value in brand ET, AC, and NES are P<0.0001 (<0.05) and established similar repeatability of results on both hands. On reliability test, the Chronbach’s alpha value for glucometer brand ET, AC, and NES on daytime measurement are 0.6964, 0.7208, and 0.5459 respectively. Meanwhile, on night-time, the alpha value is resulted in the yield 0.7814, 0.7426, and 0.7703. This study leading to the conclusion that the glucometers are valid compared to the standard method and the reliability of the glucometer is better at night-time measurement while the result of right hand blood glucose is higher than left hand meaning that the location of sample collection affects the results of the measurement. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Blood glucose monitoring is the most routine general checkup that been done independently by society regarding the incidence and prevalence of diabetes mellitus, particularly type 2. Recently, there are many self-monitoring devices for blood glucose, known as glucometer which globally market. This study aimed to determine the validity of glucometers from several brands compared to the standard method spectrophotometer which is done by clinical laboratory, determine the reliability of the glucometers, examine the impact of the location of sample collection to the result of the blood glucose measurement and also developed the information and appropriate recommendation of glucometer usage. This study was done to five subjects to compare the measurement of blood glucose using the glucometers and spectrophotometer as a standard method. Within the same time, sample collection is done on vein and capillary blood. On this study, blood samples also been taken from five subjects for twelve times in a month on the right and left hand to examine the reliability and to see any effect from sampling location. The result is statistically analyzed using the paired t-test and Cronbach's alpha. The result showed that there are no significant differences between the measurement of blood glucose using glucometers and spectrophotometer with the p-value in brand ET, AC, and NES are 0.0934, 0.0766, 0.6926 (>0.05) respectively. Next, the result of blood glucose measurement between left and right hand is significantly different with P-value in brand ET, AC, and NES are P<0.0001 (<0.05) and established similar repeatability of results on both hands. On reliability test, the Chronbach’s alpha value for glucometer brand ET, AC, and NES on daytime measurement are 0.6964, 0.7208, and 0.5459 respectively. Meanwhile, on night-time, the alpha value is resulted in the yield 0.7814, 0.7426, and 0.7703. This study leading to the conclusion that the glucometers are valid compared to the standard method and the reliability of the glucometer is better at night-time measurement while the result of right hand blood glucose is higher than left hand meaning that the location of sample collection affects the results of the measurement.
format Final Project
author Oesricha Pakki, Tasya
spellingShingle Oesricha Pakki, Tasya
UJI VALIDITAS DAN RELIABILITAS BEBERAPA ALAT SWA-MONITOR KOMERSIAL UNTUK PEMERIKSAAN KADAR GLUKOSA DARAH DAN STUDI PENGARUH FAKTOR LOKASI PENGAMBILAN SAMPEL TERHADAP HASIL PENGUKURAN
author_facet Oesricha Pakki, Tasya
author_sort Oesricha Pakki, Tasya
title UJI VALIDITAS DAN RELIABILITAS BEBERAPA ALAT SWA-MONITOR KOMERSIAL UNTUK PEMERIKSAAN KADAR GLUKOSA DARAH DAN STUDI PENGARUH FAKTOR LOKASI PENGAMBILAN SAMPEL TERHADAP HASIL PENGUKURAN
title_short UJI VALIDITAS DAN RELIABILITAS BEBERAPA ALAT SWA-MONITOR KOMERSIAL UNTUK PEMERIKSAAN KADAR GLUKOSA DARAH DAN STUDI PENGARUH FAKTOR LOKASI PENGAMBILAN SAMPEL TERHADAP HASIL PENGUKURAN
title_full UJI VALIDITAS DAN RELIABILITAS BEBERAPA ALAT SWA-MONITOR KOMERSIAL UNTUK PEMERIKSAAN KADAR GLUKOSA DARAH DAN STUDI PENGARUH FAKTOR LOKASI PENGAMBILAN SAMPEL TERHADAP HASIL PENGUKURAN
title_fullStr UJI VALIDITAS DAN RELIABILITAS BEBERAPA ALAT SWA-MONITOR KOMERSIAL UNTUK PEMERIKSAAN KADAR GLUKOSA DARAH DAN STUDI PENGARUH FAKTOR LOKASI PENGAMBILAN SAMPEL TERHADAP HASIL PENGUKURAN
title_full_unstemmed UJI VALIDITAS DAN RELIABILITAS BEBERAPA ALAT SWA-MONITOR KOMERSIAL UNTUK PEMERIKSAAN KADAR GLUKOSA DARAH DAN STUDI PENGARUH FAKTOR LOKASI PENGAMBILAN SAMPEL TERHADAP HASIL PENGUKURAN
title_sort uji validitas dan reliabilitas beberapa alat swa-monitor komersial untuk pemeriksaan kadar glukosa darah dan studi pengaruh faktor lokasi pengambilan sampel terhadap hasil pengukuran
url https://digilib.itb.ac.id/gdl/view/40294
_version_ 1821998044822896640