DEVELOPMENT AND VALIDATION METHOD OF DETERMINATION OF TRANEXAMIC ACID LEVELS IN TABLET BY FTIR AND COMPARATION WITH SPECTROPHOTOMETRY VISIBLE
Tranexamic acid is an antifibrinolytic drug that inhibits the breakdown of fibrin clots. A specific, simple, and rapid method of determination tranexamic acid levels has been developed using FTIR and the comparison will be analyzed using spectrophotometry visible. Correlations between the two wer...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/44342 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
Summary: | Tranexamic acid is an antifibrinolytic drug that inhibits the breakdown of fibrin clots. A specific,
simple, and rapid method of determination tranexamic acid levels has been developed using FTIR
and the comparison will be analyzed using spectrophotometry visible. Correlations between the
two were analyzed using t-test. The development of the method start by making the calibration
curve of a series concentrations of the active ingredient, the material mixed with KBr, to be
measured using FTIR. The spectrum is altered into the absorbance form and then derivatized.
Concentration range of 0.5-1.75%w/w at wave number 1511.08-1573.63 cm
-1
which is group NH
shows difference and linearity. The method was linear with regression y=1.3568x-0.0041,
correlation coefficient (r) = 0.9994 and Vx0 = 1.5802%. Recovery of tranexamic acid was 98.95%,
100.013%, 100.017%. Intraday and interday precision is shown by SBR 1.95%, 1.49%, 1.33% and
1.55%. LOD and LOQ of the method is 0.0531% w/w and 0.1770%w/w. This method has met the
requirements of validation. This method were compared with visible light spectrophotometry
methods using ninhydrin as derivating agents at concentrations of 3-25?g/mL at 559nm. The
method was linear the with regression y=0.0336x+0.1087, correlation coefficient (r) = 0.9992 and
Vx0 = 0.5307%. Recovery of tranexamic acid was 99.246%, 101.355%, 101.432%. Intraday and
interday precision is shown by SBR 1.183%, 0.884%, 0.279% and 0.239%, 1.224%, 1.319%. LOD
and LOQ of the method is 0.7345 %w/w and 2.448 %w/w. Determination of tranexamic acid in
commercial products has met the requirements of content in compendial. The t-test shows no
significant difference between these two methods. FTIR method has advantages such as easier,
simpler, faster and cheaper than visible light spectrophotometry method.
|
---|