Experiment of Continuous Adsorption Refrigeration System with Working Pair of R32 and Activated Carbon Modified by HNO3

Adorption refrigeration technologies are thermally driven systems. This technology is the green technology especially when applied in areas where waste heat is available. One of the main barriers to uptake of adsorption refrigeration technology is low efficiency compared with the other thermally...

Full description

Saved in:
Bibliographic Details
Main Author: Irfan Zidni, Muhamad
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/44393
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:44393
spelling id-itb.:443932019-10-17T13:42:13ZExperiment of Continuous Adsorption Refrigeration System with Working Pair of R32 and Activated Carbon Modified by HNO3 Irfan Zidni, Muhamad Indonesia Final Project refrigeration, cooling effect, COP, SCP, cycle time, activated carbon, R32, adsorption INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/44393 Adorption refrigeration technologies are thermally driven systems. This technology is the green technology especially when applied in areas where waste heat is available. One of the main barriers to uptake of adsorption refrigeration technology is low efficiency compared with the other thermally driven refrigeration system. In this research, the adsorption refrigeration system was tested using refrigerant R32 as working fluid and activated carbon modified by nitric acid (HNO3) as an adsorbent. The tests are conducted to obtain the results in the form of cycle time, cooling effect, COP, SCP, and the effect of variations in testing parameters against these values. The test results showed the value of cooling effect ranged between 17 kJ to 38 kJ for all variations of the parameters, while the cycle time is 36 minutes, 40 minutes, and 50 minutes for each value of T3 (55oC, 65oC and 75oC). COP values ranged from 0.14 to 0.25, while the values of SCP ranged between 4 W/kg to 6.3 W/kg. T3 parameter variations affect the values of calor heating and the cooling effect, while the activated carbon modification affects only the cooling effect of the machine. Additionally, the differences in testing procedures cause the differences cycle time. The testing procedure is the illustration of how the adsorption refrigeration system is operated. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Adorption refrigeration technologies are thermally driven systems. This technology is the green technology especially when applied in areas where waste heat is available. One of the main barriers to uptake of adsorption refrigeration technology is low efficiency compared with the other thermally driven refrigeration system. In this research, the adsorption refrigeration system was tested using refrigerant R32 as working fluid and activated carbon modified by nitric acid (HNO3) as an adsorbent. The tests are conducted to obtain the results in the form of cycle time, cooling effect, COP, SCP, and the effect of variations in testing parameters against these values. The test results showed the value of cooling effect ranged between 17 kJ to 38 kJ for all variations of the parameters, while the cycle time is 36 minutes, 40 minutes, and 50 minutes for each value of T3 (55oC, 65oC and 75oC). COP values ranged from 0.14 to 0.25, while the values of SCP ranged between 4 W/kg to 6.3 W/kg. T3 parameter variations affect the values of calor heating and the cooling effect, while the activated carbon modification affects only the cooling effect of the machine. Additionally, the differences in testing procedures cause the differences cycle time. The testing procedure is the illustration of how the adsorption refrigeration system is operated.
format Final Project
author Irfan Zidni, Muhamad
spellingShingle Irfan Zidni, Muhamad
Experiment of Continuous Adsorption Refrigeration System with Working Pair of R32 and Activated Carbon Modified by HNO3
author_facet Irfan Zidni, Muhamad
author_sort Irfan Zidni, Muhamad
title Experiment of Continuous Adsorption Refrigeration System with Working Pair of R32 and Activated Carbon Modified by HNO3
title_short Experiment of Continuous Adsorption Refrigeration System with Working Pair of R32 and Activated Carbon Modified by HNO3
title_full Experiment of Continuous Adsorption Refrigeration System with Working Pair of R32 and Activated Carbon Modified by HNO3
title_fullStr Experiment of Continuous Adsorption Refrigeration System with Working Pair of R32 and Activated Carbon Modified by HNO3
title_full_unstemmed Experiment of Continuous Adsorption Refrigeration System with Working Pair of R32 and Activated Carbon Modified by HNO3
title_sort experiment of continuous adsorption refrigeration system with working pair of r32 and activated carbon modified by hno3
url https://digilib.itb.ac.id/gdl/view/44393
_version_ 1821999144861958144