PENGEMBANGAN METODE SPEKTROFOTOMETRI SINAR TAMPAK MENGGUNAKAN PEREAKSI JINGGA XILENOL UNTUK PENETAPAN KADAR ZINK DALAM TABLET

Zinc sulfate is used to reduce the severity of diarrhea and administrated with oral rehydration solution. Determination of zinc sulfate in tablet is needed due to efficacy, safety, and quality of dosage form. The purpose of this study was to develop a visible spectrophotometric method for zinc de...

Full description

Saved in:
Bibliographic Details
Main Author: Apriyani Yahya, Desy
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/44760
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:44760
spelling id-itb.:447602019-11-04T16:01:35ZPENGEMBANGAN METODE SPEKTROFOTOMETRI SINAR TAMPAK MENGGUNAKAN PEREAKSI JINGGA XILENOL UNTUK PENETAPAN KADAR ZINK DALAM TABLET Apriyani Yahya, Desy Indonesia Final Project Zinc, xylenol orange, visible spectrophotometric INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/44760 Zinc sulfate is used to reduce the severity of diarrhea and administrated with oral rehydration solution. Determination of zinc sulfate in tablet is needed due to efficacy, safety, and quality of dosage form. The purpose of this study was to develop a visible spectrophotometric method for zinc determination. Measurement of zinc by the visible spectrophotometric is based on the formation of colored complexes with the reagent on certain condition. A various parameter such as reagent concentration, pH, temperature, incubation time, maximum wavelength and matrix interferences were optimized to determine optimum condition for reaction. Method validation was performed with the consideration of validation method parameters such as linearity and range, limit of detection (LOD), limit of quantification (LOQ), accuracy and precision. In this study, zinc solution was reacted with xylenol orange reagent 0.0024% w/v at pH 6, incubation allowed for 15 minutes at room temperature and the product was measured at 570 nm. Zinc that measured by this method gave linearity in the range of 1.2 ppm - 4.8 ppm with of 0.999 coefficient of correlation, 1.3% coefficient of variance, 0.137 ppm LOD and 0.415 ppm LOQ. The accuracy value which showed by recovery was in the range of 99.13% - 101.98%. Intraday and interday precision gave the coefficient of variance values less than 2%. Method is used to determine the levels of zinc in commercial tablet. The result of zinc determination in the commercial tablet fulfilled the compendia requirements. The visible spectrophotometric method with xylenol orange had been optimized, validated and could be used to determine the zinc level in tablet. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Zinc sulfate is used to reduce the severity of diarrhea and administrated with oral rehydration solution. Determination of zinc sulfate in tablet is needed due to efficacy, safety, and quality of dosage form. The purpose of this study was to develop a visible spectrophotometric method for zinc determination. Measurement of zinc by the visible spectrophotometric is based on the formation of colored complexes with the reagent on certain condition. A various parameter such as reagent concentration, pH, temperature, incubation time, maximum wavelength and matrix interferences were optimized to determine optimum condition for reaction. Method validation was performed with the consideration of validation method parameters such as linearity and range, limit of detection (LOD), limit of quantification (LOQ), accuracy and precision. In this study, zinc solution was reacted with xylenol orange reagent 0.0024% w/v at pH 6, incubation allowed for 15 minutes at room temperature and the product was measured at 570 nm. Zinc that measured by this method gave linearity in the range of 1.2 ppm - 4.8 ppm with of 0.999 coefficient of correlation, 1.3% coefficient of variance, 0.137 ppm LOD and 0.415 ppm LOQ. The accuracy value which showed by recovery was in the range of 99.13% - 101.98%. Intraday and interday precision gave the coefficient of variance values less than 2%. Method is used to determine the levels of zinc in commercial tablet. The result of zinc determination in the commercial tablet fulfilled the compendia requirements. The visible spectrophotometric method with xylenol orange had been optimized, validated and could be used to determine the zinc level in tablet.
format Final Project
author Apriyani Yahya, Desy
spellingShingle Apriyani Yahya, Desy
PENGEMBANGAN METODE SPEKTROFOTOMETRI SINAR TAMPAK MENGGUNAKAN PEREAKSI JINGGA XILENOL UNTUK PENETAPAN KADAR ZINK DALAM TABLET
author_facet Apriyani Yahya, Desy
author_sort Apriyani Yahya, Desy
title PENGEMBANGAN METODE SPEKTROFOTOMETRI SINAR TAMPAK MENGGUNAKAN PEREAKSI JINGGA XILENOL UNTUK PENETAPAN KADAR ZINK DALAM TABLET
title_short PENGEMBANGAN METODE SPEKTROFOTOMETRI SINAR TAMPAK MENGGUNAKAN PEREAKSI JINGGA XILENOL UNTUK PENETAPAN KADAR ZINK DALAM TABLET
title_full PENGEMBANGAN METODE SPEKTROFOTOMETRI SINAR TAMPAK MENGGUNAKAN PEREAKSI JINGGA XILENOL UNTUK PENETAPAN KADAR ZINK DALAM TABLET
title_fullStr PENGEMBANGAN METODE SPEKTROFOTOMETRI SINAR TAMPAK MENGGUNAKAN PEREAKSI JINGGA XILENOL UNTUK PENETAPAN KADAR ZINK DALAM TABLET
title_full_unstemmed PENGEMBANGAN METODE SPEKTROFOTOMETRI SINAR TAMPAK MENGGUNAKAN PEREAKSI JINGGA XILENOL UNTUK PENETAPAN KADAR ZINK DALAM TABLET
title_sort pengembangan metode spektrofotometri sinar tampak menggunakan pereaksi jingga xilenol untuk penetapan kadar zink dalam tablet
url https://digilib.itb.ac.id/gdl/view/44760
_version_ 1822926938603257856