PENENTUAN KADAR FORMALDEHIDA DALAM TAHU SECARA KOLORIMETRI MENGGUNAKAN PEREAKSI SCHRYVER

Tofu is a fresh processed food made of soybeans with high protein content widely consumed by many people in Indonesia. As a fresh processed food, the shelf life of tofu is only 1-2 days. However, there are many cases of misuse of hazardous substances, especially that of formaldehyde, which is add...

Full description

Saved in:
Bibliographic Details
Main Author: 'ulya, Nikmatul
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/45419
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:45419
spelling id-itb.:454192019-12-19T13:42:12ZPENENTUAN KADAR FORMALDEHIDA DALAM TAHU SECARA KOLORIMETRI MENGGUNAKAN PEREAKSI SCHRYVER 'ulya, Nikmatul Indonesia Final Project - INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/45419 Tofu is a fresh processed food made of soybeans with high protein content widely consumed by many people in Indonesia. As a fresh processed food, the shelf life of tofu is only 1-2 days. However, there are many cases of misuse of hazardous substances, especially that of formaldehyde, which is added into tofu or its marinating liquid to improved elasticity and or to preserve this products. The aims of this research were to obtain an analytical method for determination of formaldehyde in tofu by means of Schryver method and data of formaldehyde content in tofu from various sales locations. Tofu sample was homogenised and acidified by addition of 10% phosporic acid solution. The sample was then distilled and the distillate was neutralized with sodium hydroxide solution to resulte in analyte solution. This solution was reacted with Schryver reagent to form red solution measurable by UV-Vis spectrophotometer at maximum wavelength of 518 nm. Analytical method was validated and determination of formaldehyde in sample was performed. Measurement of formaldehyde standard solutions resulted in a linear calibration curve of y = 0.0864 x + 0.0203 with correlation coefficient (r) of 0.9996. Limit of detection (LOD) and limit of quantitation (LOQ) of the method was 0.24 and 0.66 µg/mL, respectively. Method precision stated as coefficient of variance (CV) of intraday measurements were 3.323 and 2.659 %, respectively. Recovery percentage of standard additions at the concentration levels of 104.91, 100.78 and 95.13%. The concentration of formaldehyde in tofu sample from various sales locations, were in the range of 0.9- 6.3µg/gr with the average concentration of 1.7 µg/gr. Based on these results, it was concluded that an analytical method for determination of formaldehyde in tofu and data of formaldehyde in this product from various sales location were succesfully obtained. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Tofu is a fresh processed food made of soybeans with high protein content widely consumed by many people in Indonesia. As a fresh processed food, the shelf life of tofu is only 1-2 days. However, there are many cases of misuse of hazardous substances, especially that of formaldehyde, which is added into tofu or its marinating liquid to improved elasticity and or to preserve this products. The aims of this research were to obtain an analytical method for determination of formaldehyde in tofu by means of Schryver method and data of formaldehyde content in tofu from various sales locations. Tofu sample was homogenised and acidified by addition of 10% phosporic acid solution. The sample was then distilled and the distillate was neutralized with sodium hydroxide solution to resulte in analyte solution. This solution was reacted with Schryver reagent to form red solution measurable by UV-Vis spectrophotometer at maximum wavelength of 518 nm. Analytical method was validated and determination of formaldehyde in sample was performed. Measurement of formaldehyde standard solutions resulted in a linear calibration curve of y = 0.0864 x + 0.0203 with correlation coefficient (r) of 0.9996. Limit of detection (LOD) and limit of quantitation (LOQ) of the method was 0.24 and 0.66 µg/mL, respectively. Method precision stated as coefficient of variance (CV) of intraday measurements were 3.323 and 2.659 %, respectively. Recovery percentage of standard additions at the concentration levels of 104.91, 100.78 and 95.13%. The concentration of formaldehyde in tofu sample from various sales locations, were in the range of 0.9- 6.3µg/gr with the average concentration of 1.7 µg/gr. Based on these results, it was concluded that an analytical method for determination of formaldehyde in tofu and data of formaldehyde in this product from various sales location were succesfully obtained.
format Final Project
author 'ulya, Nikmatul
spellingShingle 'ulya, Nikmatul
PENENTUAN KADAR FORMALDEHIDA DALAM TAHU SECARA KOLORIMETRI MENGGUNAKAN PEREAKSI SCHRYVER
author_facet 'ulya, Nikmatul
author_sort 'ulya, Nikmatul
title PENENTUAN KADAR FORMALDEHIDA DALAM TAHU SECARA KOLORIMETRI MENGGUNAKAN PEREAKSI SCHRYVER
title_short PENENTUAN KADAR FORMALDEHIDA DALAM TAHU SECARA KOLORIMETRI MENGGUNAKAN PEREAKSI SCHRYVER
title_full PENENTUAN KADAR FORMALDEHIDA DALAM TAHU SECARA KOLORIMETRI MENGGUNAKAN PEREAKSI SCHRYVER
title_fullStr PENENTUAN KADAR FORMALDEHIDA DALAM TAHU SECARA KOLORIMETRI MENGGUNAKAN PEREAKSI SCHRYVER
title_full_unstemmed PENENTUAN KADAR FORMALDEHIDA DALAM TAHU SECARA KOLORIMETRI MENGGUNAKAN PEREAKSI SCHRYVER
title_sort penentuan kadar formaldehida dalam tahu secara kolorimetri menggunakan pereaksi schryver
url https://digilib.itb.ac.id/gdl/view/45419
_version_ 1821999356571549696