PENGEMBANGAN DAN VALIDASI METODE PENETAPAN KADAR ASIKLOVIR DALAM SEDIAAN TABLET ASIKLOVIR MENGGUNAKAN FTIR

Acyclovir is a synthetic purine nucleoside analogue for the treatment and prophylaxis of infections due to herpes simplex virus types 1 and 2 and varicela-zoster virus. Some quantitative analytical methods of acyclovir have been reported using high performance liquid chromatography and UV-Vis spe...

Full description

Saved in:
Bibliographic Details
Main Author: Vianita Mussadah, Mega
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/45444
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:45444
spelling id-itb.:454442019-12-20T14:40:11ZPENGEMBANGAN DAN VALIDASI METODE PENETAPAN KADAR ASIKLOVIR DALAM SEDIAAN TABLET ASIKLOVIR MENGGUNAKAN FTIR Vianita Mussadah, Mega Indonesia Final Project acyclovir, tablet, FTIR, validation, content determination. INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/45444 Acyclovir is a synthetic purine nucleoside analogue for the treatment and prophylaxis of infections due to herpes simplex virus types 1 and 2 and varicela-zoster virus. Some quantitative analytical methods of acyclovir have been reported using high performance liquid chromatography and UV-Vis spectrophotometry. However, this methods need many toxic solvents, more consuming time and relatively expensive. The aim of this research is to develop FTIR as more rapid and cheaper alternative method for determination acyclovir in acyclovir tablet. Infrared spectrum of acyclovir was changed to be a first derivative spectra, then measured the AUC (area under the curve). Calibration curve was made in concentration of 0.2-1.2% w/w and wavenumber was optimized at 3700-3440, 3012-2870, 1955-1680, 1176-1072, and 721-609 cm -1 . Analytical method in this research was validated by specificity, linearity, limit of detection, limit of quantification, accuracy and precision test. After this method had good validated, amount of acyclovir in tablet were measured. The optimal wavenumber in this research was 3700-3440 cm -1 and produced a regression equation y = 54.922x + 17.479 with correlation coefficient (r) 0.9999 and variation coefficient of linear regression (Vxo) 0.45%. Specificity test showed that this method was specific. The limit of detection and limit of quantification was obtained at 0.01 and 0.03 % w/w. Recovery of accuracy test was 99.98-101.21%. Relative standard deviation of precision test was 0.27- 0.38% and Horrat value was 0.07-0.09. Acyclovir tablet of sample A, B, and C contained acyclovir respectively 103.49-103.77; 101.27-102.33; and 98.92-100.02%. All of the result of this research showed that FTIR can used as good validated alternative method, more rapid and cheaper for determination acyclovir in acyclovir tablet. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Acyclovir is a synthetic purine nucleoside analogue for the treatment and prophylaxis of infections due to herpes simplex virus types 1 and 2 and varicela-zoster virus. Some quantitative analytical methods of acyclovir have been reported using high performance liquid chromatography and UV-Vis spectrophotometry. However, this methods need many toxic solvents, more consuming time and relatively expensive. The aim of this research is to develop FTIR as more rapid and cheaper alternative method for determination acyclovir in acyclovir tablet. Infrared spectrum of acyclovir was changed to be a first derivative spectra, then measured the AUC (area under the curve). Calibration curve was made in concentration of 0.2-1.2% w/w and wavenumber was optimized at 3700-3440, 3012-2870, 1955-1680, 1176-1072, and 721-609 cm -1 . Analytical method in this research was validated by specificity, linearity, limit of detection, limit of quantification, accuracy and precision test. After this method had good validated, amount of acyclovir in tablet were measured. The optimal wavenumber in this research was 3700-3440 cm -1 and produced a regression equation y = 54.922x + 17.479 with correlation coefficient (r) 0.9999 and variation coefficient of linear regression (Vxo) 0.45%. Specificity test showed that this method was specific. The limit of detection and limit of quantification was obtained at 0.01 and 0.03 % w/w. Recovery of accuracy test was 99.98-101.21%. Relative standard deviation of precision test was 0.27- 0.38% and Horrat value was 0.07-0.09. Acyclovir tablet of sample A, B, and C contained acyclovir respectively 103.49-103.77; 101.27-102.33; and 98.92-100.02%. All of the result of this research showed that FTIR can used as good validated alternative method, more rapid and cheaper for determination acyclovir in acyclovir tablet.
format Final Project
author Vianita Mussadah, Mega
spellingShingle Vianita Mussadah, Mega
PENGEMBANGAN DAN VALIDASI METODE PENETAPAN KADAR ASIKLOVIR DALAM SEDIAAN TABLET ASIKLOVIR MENGGUNAKAN FTIR
author_facet Vianita Mussadah, Mega
author_sort Vianita Mussadah, Mega
title PENGEMBANGAN DAN VALIDASI METODE PENETAPAN KADAR ASIKLOVIR DALAM SEDIAAN TABLET ASIKLOVIR MENGGUNAKAN FTIR
title_short PENGEMBANGAN DAN VALIDASI METODE PENETAPAN KADAR ASIKLOVIR DALAM SEDIAAN TABLET ASIKLOVIR MENGGUNAKAN FTIR
title_full PENGEMBANGAN DAN VALIDASI METODE PENETAPAN KADAR ASIKLOVIR DALAM SEDIAAN TABLET ASIKLOVIR MENGGUNAKAN FTIR
title_fullStr PENGEMBANGAN DAN VALIDASI METODE PENETAPAN KADAR ASIKLOVIR DALAM SEDIAAN TABLET ASIKLOVIR MENGGUNAKAN FTIR
title_full_unstemmed PENGEMBANGAN DAN VALIDASI METODE PENETAPAN KADAR ASIKLOVIR DALAM SEDIAAN TABLET ASIKLOVIR MENGGUNAKAN FTIR
title_sort pengembangan dan validasi metode penetapan kadar asiklovir dalam sediaan tablet asiklovir menggunakan ftir
url https://digilib.itb.ac.id/gdl/view/45444
_version_ 1822927097500270592