STUDI RASIO VOLUME AIR/UDARA PADA CONTINUOUS BACKWASHING FILTER DALAM PENGOLAHAN AIR MINUM
<b>Abstract :</b><p align=\"justify\"> <br /> In a filtration operation there are two stages: filtration and backwashing. Backwashing filter media is an important process than its filtration itself. If a backwashing process in not appropriate, it causes decreasing...
Saved in:
Main Author: | |
---|---|
Format: | Theses |
Language: | Indonesia |
Subjects: | |
Online Access: | https://digilib.itb.ac.id/gdl/view/4970 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:4970 |
---|---|
spelling |
id-itb.:49702006-06-06T14:42:11ZSTUDI RASIO VOLUME AIR/UDARA PADA CONTINUOUS BACKWASHING FILTER DALAM PENGOLAHAN AIR MINUM Hardyanti , Nurandani Teknik (Rekayasa, enjinering dan kegiatan berkaitan) Indonesia Theses Backwash, Continuous backwashing filter; Rasio volume air/udara INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/4970 <b>Abstract :</b><p align=\"justify\"> <br /> In a filtration operation there are two stages: filtration and backwashing. Backwashing filter media is an important process than its filtration itself. If a backwashing process in not appropriate, it causes decreasing filters performance. Because of this reason, it is necessary to develop a continuous backwashing filter. In this filter, backwashing process and filtration process will be done at the same time by using air and water simultaneously in order to minimize wasted water demand and to make the operator\'s work easily. The aim of this study is to determine the ratio of air - water volume in a continuous backwashing filter and to find the performance of ratio of air - water volume on filter operational. Based on the research, it is found the relationship between ratio of water velocity to minimum fluidization velocity and the square of air velocity to predict the backwashing threshold using air and water simultaneously, that is 1111.898v <sup>2</sup>u + %(v <sub>a</sub> / v<sub>mf</sub>) =111.11 for minimum fluidization <br /> velocity of measurement data. Optimum removal occurs in ratio of air - water volume of temperature and pressure standard condition: 0,22 (grain diameter: 0,425 - 0,60 mm) and 0,32 (grain diameter: 0,60 - 0,8.5 mm). If that ratio reaches 1.1 so the air volume condition is not optimum. Besides, water consuming in continuous backwashing filter is 90% of semi-continuous backwashing filter. text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
topic |
Teknik (Rekayasa, enjinering dan kegiatan berkaitan) |
spellingShingle |
Teknik (Rekayasa, enjinering dan kegiatan berkaitan) Hardyanti , Nurandani STUDI RASIO VOLUME AIR/UDARA PADA CONTINUOUS BACKWASHING FILTER DALAM PENGOLAHAN AIR MINUM |
description |
<b>Abstract :</b><p align=\"justify\"> <br />
In a filtration operation there are two stages: filtration and backwashing. Backwashing filter media is an important process than its filtration itself. If a backwashing process in not appropriate, it causes decreasing filters performance. Because of this reason, it is necessary to develop a continuous backwashing filter. In this filter, backwashing process and filtration process will be done at the same time by using air and water simultaneously in order to minimize wasted water demand and to make the operator\'s work easily. The aim of this study is to determine the ratio of air - water volume in a continuous backwashing filter and to find the performance of ratio of air - water volume on filter operational. Based on the research, it is found the relationship between ratio of water velocity to minimum fluidization velocity and the square of air velocity to predict the backwashing threshold using air and water simultaneously, that is 1111.898v <sup>2</sup>u + %(v <sub>a</sub> / v<sub>mf</sub>) =111.11 for minimum fluidization <br />
velocity of measurement data. Optimum removal occurs in ratio of air - water volume of temperature and pressure standard condition: 0,22 (grain diameter: 0,425 - 0,60 mm) and 0,32 (grain diameter: 0,60 - 0,8.5 mm). If that ratio reaches 1.1 so the air volume condition is not optimum. Besides, water consuming in continuous backwashing filter is 90% of semi-continuous backwashing filter. |
format |
Theses |
author |
Hardyanti , Nurandani |
author_facet |
Hardyanti , Nurandani |
author_sort |
Hardyanti , Nurandani |
title |
STUDI RASIO VOLUME AIR/UDARA PADA CONTINUOUS BACKWASHING FILTER DALAM PENGOLAHAN AIR MINUM |
title_short |
STUDI RASIO VOLUME AIR/UDARA PADA CONTINUOUS BACKWASHING FILTER DALAM PENGOLAHAN AIR MINUM |
title_full |
STUDI RASIO VOLUME AIR/UDARA PADA CONTINUOUS BACKWASHING FILTER DALAM PENGOLAHAN AIR MINUM |
title_fullStr |
STUDI RASIO VOLUME AIR/UDARA PADA CONTINUOUS BACKWASHING FILTER DALAM PENGOLAHAN AIR MINUM |
title_full_unstemmed |
STUDI RASIO VOLUME AIR/UDARA PADA CONTINUOUS BACKWASHING FILTER DALAM PENGOLAHAN AIR MINUM |
title_sort |
studi rasio volume air/udara pada continuous backwashing filter dalam pengolahan air minum |
url |
https://digilib.itb.ac.id/gdl/view/4970 |
_version_ |
1820663548887433216 |