R-IMPACT : SOFTWARE PERHITUNGAN BESARAN RESIKO DOSIS CT PADA PENGUJIAN KEPALA MENGGUNAKAN 320-MDCT
Nowadays, the use of CT in the medical field for nerve and other related problems in the head is so massive. This has a good effect because with CT technology, the head diagnosis process that was previously time-consuming, complicated, becomes short and relatively easy. 320-MDCT is one of the latest...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/49728 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:49728 |
---|---|
spelling |
id-itb.:497282020-09-18T15:10:56ZR-IMPACT : SOFTWARE PERHITUNGAN BESARAN RESIKO DOSIS CT PADA PENGUJIAN KEPALA MENGGUNAKAN 320-MDCT Candra, Rafi Indonesia Final Project 320-MDCT, Cancer risk index, Effective dose, Head-CT, Radiation risk. INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/49728 Nowadays, the use of CT in the medical field for nerve and other related problems in the head is so massive. This has a good effect because with CT technology, the head diagnosis process that was previously time-consuming, complicated, becomes short and relatively easy. 320-MDCT is one of the latest popular technologies for head examination because of its resolution and short exposure duration. But there is no research that clearly explains whether 320-MDCT is really safe to use for head examination. Therefore in this study, a software called R-ImPACT will be made to determine the dose risk (Effective Dose and Cancer Risk Index) for head examination using 320-MDCT. R-ImPACT has the ability to calculate the amount of dose risk in MIRD-5 Phantom and ICRP 110 Phantom. In this research, the results show that R-ImPACT works well in calculating the effective dose and cancer risk index. The calculation error of R-ImPACT is around 1.25% - 2.56%. Furthermore, for head examination with 320-MDCT an effective dose value of 0.59 mSv for men and 0.58 mSv for women was obtained, and the Cancer Risk Index obtained 78 cases/100,000 for men and 131 cases/100,000 for women. These results indicate that the 320-MDCT technology is actually safer and provides a lower dose than the old technologyin head examination. text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
description |
Nowadays, the use of CT in the medical field for nerve and other related problems in the head is so massive. This has a good effect because with CT technology, the head diagnosis process that was previously time-consuming, complicated, becomes short and relatively easy. 320-MDCT is one of the latest popular technologies for head examination because of its resolution and short exposure duration. But there is no research that clearly explains whether 320-MDCT is really safe to use for head examination. Therefore in this study, a software called R-ImPACT will be made to determine the dose risk (Effective Dose and Cancer Risk Index) for head examination using 320-MDCT. R-ImPACT has the ability to calculate the amount of dose risk in MIRD-5 Phantom and ICRP 110 Phantom. In this research, the results show that R-ImPACT works well in calculating the effective dose and cancer risk index. The calculation error of R-ImPACT is around 1.25% - 2.56%. Furthermore, for head examination with 320-MDCT an effective dose value of 0.59 mSv for men and 0.58 mSv for women was obtained, and the Cancer Risk Index obtained 78 cases/100,000 for men and 131 cases/100,000 for women. These results indicate that the 320-MDCT technology is actually safer and provides a lower dose than the old technologyin head examination. |
format |
Final Project |
author |
Candra, Rafi |
spellingShingle |
Candra, Rafi R-IMPACT : SOFTWARE PERHITUNGAN BESARAN RESIKO DOSIS CT PADA PENGUJIAN KEPALA MENGGUNAKAN 320-MDCT |
author_facet |
Candra, Rafi |
author_sort |
Candra, Rafi |
title |
R-IMPACT : SOFTWARE PERHITUNGAN BESARAN RESIKO DOSIS CT PADA PENGUJIAN KEPALA MENGGUNAKAN 320-MDCT |
title_short |
R-IMPACT : SOFTWARE PERHITUNGAN BESARAN RESIKO DOSIS CT PADA PENGUJIAN KEPALA MENGGUNAKAN 320-MDCT |
title_full |
R-IMPACT : SOFTWARE PERHITUNGAN BESARAN RESIKO DOSIS CT PADA PENGUJIAN KEPALA MENGGUNAKAN 320-MDCT |
title_fullStr |
R-IMPACT : SOFTWARE PERHITUNGAN BESARAN RESIKO DOSIS CT PADA PENGUJIAN KEPALA MENGGUNAKAN 320-MDCT |
title_full_unstemmed |
R-IMPACT : SOFTWARE PERHITUNGAN BESARAN RESIKO DOSIS CT PADA PENGUJIAN KEPALA MENGGUNAKAN 320-MDCT |
title_sort |
r-impact : software perhitungan besaran resiko dosis ct pada pengujian kepala menggunakan 320-mdct |
url |
https://digilib.itb.ac.id/gdl/view/49728 |
_version_ |
1822928251996078080 |