R-IMPACT : SOFTWARE PERHITUNGAN BESARAN RESIKO DOSIS CT PADA PENGUJIAN KEPALA MENGGUNAKAN 320-MDCT

Nowadays, the use of CT in the medical field for nerve and other related problems in the head is so massive. This has a good effect because with CT technology, the head diagnosis process that was previously time-consuming, complicated, becomes short and relatively easy. 320-MDCT is one of the latest...

Full description

Saved in:
Bibliographic Details
Main Author: Candra, Rafi
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/49728
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:49728
spelling id-itb.:497282020-09-18T15:10:56ZR-IMPACT : SOFTWARE PERHITUNGAN BESARAN RESIKO DOSIS CT PADA PENGUJIAN KEPALA MENGGUNAKAN 320-MDCT Candra, Rafi Indonesia Final Project 320-MDCT, Cancer risk index, Effective dose, Head-CT, Radiation risk. INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/49728 Nowadays, the use of CT in the medical field for nerve and other related problems in the head is so massive. This has a good effect because with CT technology, the head diagnosis process that was previously time-consuming, complicated, becomes short and relatively easy. 320-MDCT is one of the latest popular technologies for head examination because of its resolution and short exposure duration. But there is no research that clearly explains whether 320-MDCT is really safe to use for head examination. Therefore in this study, a software called R-ImPACT will be made to determine the dose risk (Effective Dose and Cancer Risk Index) for head examination using 320-MDCT. R-ImPACT has the ability to calculate the amount of dose risk in MIRD-5 Phantom and ICRP 110 Phantom. In this research, the results show that R-ImPACT works well in calculating the effective dose and cancer risk index. The calculation error of R-ImPACT is around 1.25% - 2.56%. Furthermore, for head examination with 320-MDCT an effective dose value of 0.59 mSv for men and 0.58 mSv for women was obtained, and the Cancer Risk Index obtained 78 cases/100,000 for men and 131 cases/100,000 for women. These results indicate that the 320-MDCT technology is actually safer and provides a lower dose than the old technologyin head examination. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Nowadays, the use of CT in the medical field for nerve and other related problems in the head is so massive. This has a good effect because with CT technology, the head diagnosis process that was previously time-consuming, complicated, becomes short and relatively easy. 320-MDCT is one of the latest popular technologies for head examination because of its resolution and short exposure duration. But there is no research that clearly explains whether 320-MDCT is really safe to use for head examination. Therefore in this study, a software called R-ImPACT will be made to determine the dose risk (Effective Dose and Cancer Risk Index) for head examination using 320-MDCT. R-ImPACT has the ability to calculate the amount of dose risk in MIRD-5 Phantom and ICRP 110 Phantom. In this research, the results show that R-ImPACT works well in calculating the effective dose and cancer risk index. The calculation error of R-ImPACT is around 1.25% - 2.56%. Furthermore, for head examination with 320-MDCT an effective dose value of 0.59 mSv for men and 0.58 mSv for women was obtained, and the Cancer Risk Index obtained 78 cases/100,000 for men and 131 cases/100,000 for women. These results indicate that the 320-MDCT technology is actually safer and provides a lower dose than the old technologyin head examination.
format Final Project
author Candra, Rafi
spellingShingle Candra, Rafi
R-IMPACT : SOFTWARE PERHITUNGAN BESARAN RESIKO DOSIS CT PADA PENGUJIAN KEPALA MENGGUNAKAN 320-MDCT
author_facet Candra, Rafi
author_sort Candra, Rafi
title R-IMPACT : SOFTWARE PERHITUNGAN BESARAN RESIKO DOSIS CT PADA PENGUJIAN KEPALA MENGGUNAKAN 320-MDCT
title_short R-IMPACT : SOFTWARE PERHITUNGAN BESARAN RESIKO DOSIS CT PADA PENGUJIAN KEPALA MENGGUNAKAN 320-MDCT
title_full R-IMPACT : SOFTWARE PERHITUNGAN BESARAN RESIKO DOSIS CT PADA PENGUJIAN KEPALA MENGGUNAKAN 320-MDCT
title_fullStr R-IMPACT : SOFTWARE PERHITUNGAN BESARAN RESIKO DOSIS CT PADA PENGUJIAN KEPALA MENGGUNAKAN 320-MDCT
title_full_unstemmed R-IMPACT : SOFTWARE PERHITUNGAN BESARAN RESIKO DOSIS CT PADA PENGUJIAN KEPALA MENGGUNAKAN 320-MDCT
title_sort r-impact : software perhitungan besaran resiko dosis ct pada pengujian kepala menggunakan 320-mdct
url https://digilib.itb.ac.id/gdl/view/49728
_version_ 1822928251996078080