DESIGN OF FILTRATION, DISINFECTION, AND RESERVOIR UNIT AT SADU WATER TREATMENT PLANT (WTP) STAGE II, BANDUNG DISTRICT

In order to achieve the RPJMN program of 100% clean water access, Perumda Air Minum Tirta Raharja provides access to clean water for people in Bandung District through Gambung SPAM equipped with Sadu Water Treatment Plant (WTP). However, the Sadu WTP with a capacity of 250 L/second is only sufficien...

Full description

Saved in:
Bibliographic Details
Main Author: Luvita, Firani
Format: Final Project
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/51257
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:51257
spelling id-itb.:512572020-09-28T07:43:55ZDESIGN OF FILTRATION, DISINFECTION, AND RESERVOIR UNIT AT SADU WATER TREATMENT PLANT (WTP) STAGE II, BANDUNG DISTRICT Luvita, Firani Teknik saniter dan perkotaan; teknik perlindungan lingkungan Indonesia Final Project disinfection, filtration, quality standards, reservoir, Sadu WTP. INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/51257 In order to achieve the RPJMN program of 100% clean water access, Perumda Air Minum Tirta Raharja provides access to clean water for people in Bandung District through Gambung SPAM equipped with Sadu Water Treatment Plant (WTP). However, the Sadu WTP with a capacity of 250 L/second is only sufficient to serve the water demand of Soreang, Katapang and parts of Margaasih and Margahayu Subdistricts. Therefore, the Sadu WTP Stage II with a capacity of 150 L/second will be built to serve Kutawaringin, Margahayu and Margaasih subdistricts. Sadu WTP Stage II is located in Sadu Village, Soreang District, covering an area of 3,947 m2 with raw water coming from the Cisondari River. Based on the projection of water demand, WTP Sadu can provide a service level of 14%. The water quality of the Cisondari river has several parameters that do not meet Class I water quality standards Government Regulation PP 82/2001 and Indonesia Minister of Health Regulation 492/2010, such as turbidity, fecal coliform, total coliform, and phenol. Referring to the characteristics of raw water, the selected treatment series is conventional. Based on the weighting using the Simple Additive Weighting (SAW) method and considering several aspects, the selected treatment alternatives for filtration, disinfection and reservoir units are dual media rapid sand filter, chlorine disinfection, and ground reservoir. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
topic Teknik saniter dan perkotaan; teknik perlindungan lingkungan
spellingShingle Teknik saniter dan perkotaan; teknik perlindungan lingkungan
Luvita, Firani
DESIGN OF FILTRATION, DISINFECTION, AND RESERVOIR UNIT AT SADU WATER TREATMENT PLANT (WTP) STAGE II, BANDUNG DISTRICT
description In order to achieve the RPJMN program of 100% clean water access, Perumda Air Minum Tirta Raharja provides access to clean water for people in Bandung District through Gambung SPAM equipped with Sadu Water Treatment Plant (WTP). However, the Sadu WTP with a capacity of 250 L/second is only sufficient to serve the water demand of Soreang, Katapang and parts of Margaasih and Margahayu Subdistricts. Therefore, the Sadu WTP Stage II with a capacity of 150 L/second will be built to serve Kutawaringin, Margahayu and Margaasih subdistricts. Sadu WTP Stage II is located in Sadu Village, Soreang District, covering an area of 3,947 m2 with raw water coming from the Cisondari River. Based on the projection of water demand, WTP Sadu can provide a service level of 14%. The water quality of the Cisondari river has several parameters that do not meet Class I water quality standards Government Regulation PP 82/2001 and Indonesia Minister of Health Regulation 492/2010, such as turbidity, fecal coliform, total coliform, and phenol. Referring to the characteristics of raw water, the selected treatment series is conventional. Based on the weighting using the Simple Additive Weighting (SAW) method and considering several aspects, the selected treatment alternatives for filtration, disinfection and reservoir units are dual media rapid sand filter, chlorine disinfection, and ground reservoir.
format Final Project
author Luvita, Firani
author_facet Luvita, Firani
author_sort Luvita, Firani
title DESIGN OF FILTRATION, DISINFECTION, AND RESERVOIR UNIT AT SADU WATER TREATMENT PLANT (WTP) STAGE II, BANDUNG DISTRICT
title_short DESIGN OF FILTRATION, DISINFECTION, AND RESERVOIR UNIT AT SADU WATER TREATMENT PLANT (WTP) STAGE II, BANDUNG DISTRICT
title_full DESIGN OF FILTRATION, DISINFECTION, AND RESERVOIR UNIT AT SADU WATER TREATMENT PLANT (WTP) STAGE II, BANDUNG DISTRICT
title_fullStr DESIGN OF FILTRATION, DISINFECTION, AND RESERVOIR UNIT AT SADU WATER TREATMENT PLANT (WTP) STAGE II, BANDUNG DISTRICT
title_full_unstemmed DESIGN OF FILTRATION, DISINFECTION, AND RESERVOIR UNIT AT SADU WATER TREATMENT PLANT (WTP) STAGE II, BANDUNG DISTRICT
title_sort design of filtration, disinfection, and reservoir unit at sadu water treatment plant (wtp) stage ii, bandung district
url https://digilib.itb.ac.id/gdl/view/51257
_version_ 1822272633604931584