COMPUTER SIMULATION OF LEAKAGE CURRENT ON INSULATOR TO PREDICTS INSULATOR CHARACTERISTIC IN CLEAN FOG CONDITION

In the projection, the insulator is expected to function for a long time, approximately 10- 15 years, depending on the type of material used. However, electrical pressure, mechanical stress, environmental influences, and ultraviolet rays can affect the working time of the insulator to shorten....

Full description

Saved in:
Bibliographic Details
Main Author: Bagaskara, Adjie
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/55221
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:55221
spelling id-itb.:552212021-06-16T11:54:13ZCOMPUTER SIMULATION OF LEAKAGE CURRENT ON INSULATOR TO PREDICTS INSULATOR CHARACTERISTIC IN CLEAN FOG CONDITION Bagaskara, Adjie Indonesia Final Project Insulation, Simulation, Leakage Current, Electrical Circuit Equivalent, Characteristic INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/55221 In the projection, the insulator is expected to function for a long time, approximately 10- 15 years, depending on the type of material used. However, electrical pressure, mechanical stress, environmental influences, and ultraviolet rays can affect the working time of the insulator to shorten. Moreover, it can cause failure of the electrical power system insulation. Indonesia, which is a tropical country, has higher ultraviolet rays, rainfall, and humidity than non-tropical countries. This exacerbates the outer pair isolator. Some of the external tide isolators in Indonesia are installed in mountainous areas that have clean fog characteristics. To determine the response of the insulator from environmental effects, a simulation study of the leakage current passing through the surface of the insulator was carried out using ATPDraw software. The simulation uses an electric equivalent circuit consisting of a Suwarno models and a arc models. The results obtained from the simulation are compared with laboratory results to obtain the characteristics of these insulators. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description In the projection, the insulator is expected to function for a long time, approximately 10- 15 years, depending on the type of material used. However, electrical pressure, mechanical stress, environmental influences, and ultraviolet rays can affect the working time of the insulator to shorten. Moreover, it can cause failure of the electrical power system insulation. Indonesia, which is a tropical country, has higher ultraviolet rays, rainfall, and humidity than non-tropical countries. This exacerbates the outer pair isolator. Some of the external tide isolators in Indonesia are installed in mountainous areas that have clean fog characteristics. To determine the response of the insulator from environmental effects, a simulation study of the leakage current passing through the surface of the insulator was carried out using ATPDraw software. The simulation uses an electric equivalent circuit consisting of a Suwarno models and a arc models. The results obtained from the simulation are compared with laboratory results to obtain the characteristics of these insulators.
format Final Project
author Bagaskara, Adjie
spellingShingle Bagaskara, Adjie
COMPUTER SIMULATION OF LEAKAGE CURRENT ON INSULATOR TO PREDICTS INSULATOR CHARACTERISTIC IN CLEAN FOG CONDITION
author_facet Bagaskara, Adjie
author_sort Bagaskara, Adjie
title COMPUTER SIMULATION OF LEAKAGE CURRENT ON INSULATOR TO PREDICTS INSULATOR CHARACTERISTIC IN CLEAN FOG CONDITION
title_short COMPUTER SIMULATION OF LEAKAGE CURRENT ON INSULATOR TO PREDICTS INSULATOR CHARACTERISTIC IN CLEAN FOG CONDITION
title_full COMPUTER SIMULATION OF LEAKAGE CURRENT ON INSULATOR TO PREDICTS INSULATOR CHARACTERISTIC IN CLEAN FOG CONDITION
title_fullStr COMPUTER SIMULATION OF LEAKAGE CURRENT ON INSULATOR TO PREDICTS INSULATOR CHARACTERISTIC IN CLEAN FOG CONDITION
title_full_unstemmed COMPUTER SIMULATION OF LEAKAGE CURRENT ON INSULATOR TO PREDICTS INSULATOR CHARACTERISTIC IN CLEAN FOG CONDITION
title_sort computer simulation of leakage current on insulator to predicts insulator characteristic in clean fog condition
url https://digilib.itb.ac.id/gdl/view/55221
_version_ 1822002007069687808