DESAIN STIMULASI DENGAN METODE AIR COMPRESSION PADA SUMUR GEOTERMAL DOMINASI AIR

By the time the wellhead was opened after well testing, often fluid can not flow naturally to the surface so it takes extra effort to discharge the well, usually occurs in water-dominated system. It is usually due to the water column above the permeable zone so that makes hydrostatic pressure in the...

Full description

Saved in:
Bibliographic Details
Main Author: Chessie C, Natassha
Format: Final Project
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/57308
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:57308
spelling id-itb.:573082021-08-10T16:00:35ZDESAIN STIMULASI DENGAN METODE AIR COMPRESSION PADA SUMUR GEOTERMAL DOMINASI AIR Chessie C, Natassha Pertambangan dan operasi berkaitan Indonesia Final Project geothermal stimulation, air compression, ratio of Af and Ac method, non-self discharge INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/57308 By the time the wellhead was opened after well testing, often fluid can not flow naturally to the surface so it takes extra effort to discharge the well, usually occurs in water-dominated system. It is usually due to the water column above the permeable zone so that makes hydrostatic pressure in the well is greater than the reservoir pressure. To be able to flow to the surface, the fluid from the reservoir needs to be in a condition where the pressure reservoir must be greater than the pressure inside the wellbore. Thus to be able to make a well flow, an effort to reduce the hydrostatic pressure within the well bore is required. One was conducted by stimulation of compressed air (air compression stimulation). Stimulation by air compression operates on the idea that water is depressed down the well to a certain depth in order to reduce the hydrostatic pressure. In this study, stimulation designs have been made for eight non-self discharge (not flowing naturally) wells in water-dominated system using a method, which is the ratio between the flashing area and condensation area in the wellbore. From this study, it can be concluded that compression pressure needed for the success of this method is compression pressure that produces the ratio Af/Ac after stimulation greater than 0.85. Prediction using Af and Ac method is not always accurate for certain wells. In field practice, if the theoretical approach does not work then the practical approach will be used by increasing the compression pressure gradually until the well can discharge. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
topic Pertambangan dan operasi berkaitan
spellingShingle Pertambangan dan operasi berkaitan
Chessie C, Natassha
DESAIN STIMULASI DENGAN METODE AIR COMPRESSION PADA SUMUR GEOTERMAL DOMINASI AIR
description By the time the wellhead was opened after well testing, often fluid can not flow naturally to the surface so it takes extra effort to discharge the well, usually occurs in water-dominated system. It is usually due to the water column above the permeable zone so that makes hydrostatic pressure in the well is greater than the reservoir pressure. To be able to flow to the surface, the fluid from the reservoir needs to be in a condition where the pressure reservoir must be greater than the pressure inside the wellbore. Thus to be able to make a well flow, an effort to reduce the hydrostatic pressure within the well bore is required. One was conducted by stimulation of compressed air (air compression stimulation). Stimulation by air compression operates on the idea that water is depressed down the well to a certain depth in order to reduce the hydrostatic pressure. In this study, stimulation designs have been made for eight non-self discharge (not flowing naturally) wells in water-dominated system using a method, which is the ratio between the flashing area and condensation area in the wellbore. From this study, it can be concluded that compression pressure needed for the success of this method is compression pressure that produces the ratio Af/Ac after stimulation greater than 0.85. Prediction using Af and Ac method is not always accurate for certain wells. In field practice, if the theoretical approach does not work then the practical approach will be used by increasing the compression pressure gradually until the well can discharge.
format Final Project
author Chessie C, Natassha
author_facet Chessie C, Natassha
author_sort Chessie C, Natassha
title DESAIN STIMULASI DENGAN METODE AIR COMPRESSION PADA SUMUR GEOTERMAL DOMINASI AIR
title_short DESAIN STIMULASI DENGAN METODE AIR COMPRESSION PADA SUMUR GEOTERMAL DOMINASI AIR
title_full DESAIN STIMULASI DENGAN METODE AIR COMPRESSION PADA SUMUR GEOTERMAL DOMINASI AIR
title_fullStr DESAIN STIMULASI DENGAN METODE AIR COMPRESSION PADA SUMUR GEOTERMAL DOMINASI AIR
title_full_unstemmed DESAIN STIMULASI DENGAN METODE AIR COMPRESSION PADA SUMUR GEOTERMAL DOMINASI AIR
title_sort desain stimulasi dengan metode air compression pada sumur geotermal dominasi air
url https://digilib.itb.ac.id/gdl/view/57308
_version_ 1822930431094292480