Zeolite Based Carbon Paste Electrode for Voltammetric Determination of Ascorbic Acid

Abstract : <br /> <br /> <br /> <br /> <br /> <br /> A new differential pulse voltammetry (DPV) method for determination of ascorbic acid (AA) had been developed using zeolite modified carbon paste electrode (ZCPE). Rate of electron transfer of AA s oxidatio...

Full description

Saved in:
Bibliographic Details
Main Author: Irawan, Dhanie
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/5947
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:5947
spelling id-itb.:59472017-09-27T11:42:32ZZeolite Based Carbon Paste Electrode for Voltammetric Determination of Ascorbic Acid Irawan, Dhanie Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/5947 Abstract : <br /> <br /> <br /> <br /> <br /> <br /> A new differential pulse voltammetry (DPV) method for determination of ascorbic acid (AA) had been developed using zeolite modified carbon paste electrode (ZCPE). Rate of electron transfer of AA s oxidation on the ZCPE is slow. Therefore, methylene blue (MB) was used for electron transfer mediator to increase the rate. The differential pulse voltamogram was made in the potential range of -700 to 400 mV. The anodic peak of MB increases with AA concentration. The calibration curves of AA were linear in the concentration range of 1 M to 1 mM with detection limit of 0.9 M. Percent recovery of AA analysis was between 98.41% - 100.29%, which showed a good accuracy. Application of the method to determine AA in real samples showed accurate result. On the contrary, matrix has a responsible effect in AA s determination in real samples. <br /> text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Abstract : <br /> <br /> <br /> <br /> <br /> <br /> A new differential pulse voltammetry (DPV) method for determination of ascorbic acid (AA) had been developed using zeolite modified carbon paste electrode (ZCPE). Rate of electron transfer of AA s oxidation on the ZCPE is slow. Therefore, methylene blue (MB) was used for electron transfer mediator to increase the rate. The differential pulse voltamogram was made in the potential range of -700 to 400 mV. The anodic peak of MB increases with AA concentration. The calibration curves of AA were linear in the concentration range of 1 M to 1 mM with detection limit of 0.9 M. Percent recovery of AA analysis was between 98.41% - 100.29%, which showed a good accuracy. Application of the method to determine AA in real samples showed accurate result. On the contrary, matrix has a responsible effect in AA s determination in real samples. <br />
format Final Project
author Irawan, Dhanie
spellingShingle Irawan, Dhanie
Zeolite Based Carbon Paste Electrode for Voltammetric Determination of Ascorbic Acid
author_facet Irawan, Dhanie
author_sort Irawan, Dhanie
title Zeolite Based Carbon Paste Electrode for Voltammetric Determination of Ascorbic Acid
title_short Zeolite Based Carbon Paste Electrode for Voltammetric Determination of Ascorbic Acid
title_full Zeolite Based Carbon Paste Electrode for Voltammetric Determination of Ascorbic Acid
title_fullStr Zeolite Based Carbon Paste Electrode for Voltammetric Determination of Ascorbic Acid
title_full_unstemmed Zeolite Based Carbon Paste Electrode for Voltammetric Determination of Ascorbic Acid
title_sort zeolite based carbon paste electrode for voltammetric determination of ascorbic acid
url https://digilib.itb.ac.id/gdl/view/5947
_version_ 1820663788919062528