#TITLE_ALTERNATIVE#

Abstract: <br /> <br /> <br /> <br /> <br /> <br /> A gas chromatographic method has been developed for determination of d-allethrin in antimosquito vapourising mat. The mat was scissored, added with dibutyl phthalate as internal standard and extracted with a...

Full description

Saved in:
Bibliographic Details
Main Author: (NIM 107 03 089), Fenny
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/6105
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:6105
spelling id-itb.:61052012-05-31T11:34:23Z#TITLE_ALTERNATIVE# (NIM 107 03 089), Fenny Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/6105 Abstract: <br /> <br /> <br /> <br /> <br /> <br /> A gas chromatographic method has been developed for determination of d-allethrin in antimosquito vapourising mat. The mat was scissored, added with dibutyl phthalate as internal standard and extracted with acetone. The solution was analysed by gas chromatography on an OV-1 capillary column 25 m x 0.53 mm and detected by using a flame ionization detector. The method has been validated by testing its recovery, precision, linearity, and sensitivity. The recovery from spiked samples ranged from 92 to 103 Percent, the coefficient of variation ranged from 1.51 - 2.04 Percent, the coefficient of corelation was 0.999, limit of detection was 0.58 mg/mL, and limit of quantification was 1.75 mg/mL. <br /> text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Abstract: <br /> <br /> <br /> <br /> <br /> <br /> A gas chromatographic method has been developed for determination of d-allethrin in antimosquito vapourising mat. The mat was scissored, added with dibutyl phthalate as internal standard and extracted with acetone. The solution was analysed by gas chromatography on an OV-1 capillary column 25 m x 0.53 mm and detected by using a flame ionization detector. The method has been validated by testing its recovery, precision, linearity, and sensitivity. The recovery from spiked samples ranged from 92 to 103 Percent, the coefficient of variation ranged from 1.51 - 2.04 Percent, the coefficient of corelation was 0.999, limit of detection was 0.58 mg/mL, and limit of quantification was 1.75 mg/mL. <br />
format Final Project
author (NIM 107 03 089), Fenny
spellingShingle (NIM 107 03 089), Fenny
#TITLE_ALTERNATIVE#
author_facet (NIM 107 03 089), Fenny
author_sort (NIM 107 03 089), Fenny
title #TITLE_ALTERNATIVE#
title_short #TITLE_ALTERNATIVE#
title_full #TITLE_ALTERNATIVE#
title_fullStr #TITLE_ALTERNATIVE#
title_full_unstemmed #TITLE_ALTERNATIVE#
title_sort #title_alternative#
url https://digilib.itb.ac.id/gdl/view/6105
_version_ 1820663820610174976