Abstract: <br /> <br /> <br /> <br /> <br /> <br /> A gas chromatographic method has been developed for determination of d-allethrin in antimosquito vapourising mat. The mat was scissored, added with dibutyl phthalate as internal standard and extracted with a...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/6105 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:6105 |
---|---|
spelling |
id-itb.:61052012-05-31T11:34:23Z#TITLE_ALTERNATIVE# (NIM 107 03 089), Fenny Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/6105 Abstract: <br /> <br /> <br /> <br /> <br /> <br /> A gas chromatographic method has been developed for determination of d-allethrin in antimosquito vapourising mat. The mat was scissored, added with dibutyl phthalate as internal standard and extracted with acetone. The solution was analysed by gas chromatography on an OV-1 capillary column 25 m x 0.53 mm and detected by using a flame ionization detector. The method has been validated by testing its recovery, precision, linearity, and sensitivity. The recovery from spiked samples ranged from 92 to 103 Percent, the coefficient of variation ranged from 1.51 - 2.04 Percent, the coefficient of corelation was 0.999, limit of detection was 0.58 mg/mL, and limit of quantification was 1.75 mg/mL. <br /> text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
description |
Abstract: <br />
<br />
<br />
<br />
<br />
<br />
A gas chromatographic method has been developed for determination of d-allethrin in antimosquito vapourising mat. The mat was scissored, added with dibutyl phthalate as internal standard and extracted with acetone. The solution was analysed by gas chromatography on an OV-1 capillary column 25 m x 0.53 mm and detected by using a flame ionization detector. The method has been validated by testing its recovery, precision, linearity, and sensitivity. The recovery from spiked samples ranged from 92 to 103 Percent, the coefficient of variation ranged from 1.51 - 2.04 Percent, the coefficient of corelation was 0.999, limit of detection was 0.58 mg/mL, and limit of quantification was 1.75 mg/mL. <br />
|
format |
Final Project |
author |
(NIM 107 03 089), Fenny |
spellingShingle |
(NIM 107 03 089), Fenny #TITLE_ALTERNATIVE# |
author_facet |
(NIM 107 03 089), Fenny |
author_sort |
(NIM 107 03 089), Fenny |
title |
#TITLE_ALTERNATIVE# |
title_short |
#TITLE_ALTERNATIVE# |
title_full |
#TITLE_ALTERNATIVE# |
title_fullStr |
#TITLE_ALTERNATIVE# |
title_full_unstemmed |
#TITLE_ALTERNATIVE# |
title_sort |
#title_alternative# |
url |
https://digilib.itb.ac.id/gdl/view/6105 |
_version_ |
1820663820610174976 |